User manual DUCATI CTR19

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DUCATI CTR19. We hope that this DUCATI CTR19 user guide will be useful to you.

Lastmanuals help download the user guide DUCATI CTR19.


Mode d'emploi DUCATI CTR19
Download
Manual abstract: user guide DUCATI CTR19

Detailed instructions for use are in the User's Guide.

[. . . ] Any inaccuracies or errors found in this manual will be corrected in the next edition. Electronic board controlling 1 or 2 230 Vac single-phase asynchronous motors for the automation of a single or two wing/sliding gate with or without limit switch. Caution : Before operating the electronic unit make sure the following operations have been carried out. Note 1 ­ Note 2 ­ Note 3 Note 4 Note 5 Note 6 Note 7 ­ ­ ­ ­ ­ Read carefully the whole technical documentation supplied. [. . . ] The led goes off when the stop control is operated (emergency). LD1 ­ Power supply led (green) It is lit when the electronic card power supply is present. RV2 - M2 Delay It defines the delay between the first wing's (M1) and the second wing's (M2) start during the closure phase. RV1 ­ Work time It defines the motors' work time during the opening or closure phases. SW1 - Dip switch 1 It enables or excludes the kickback (during the opening phase with closed gate) : ON= Kickback enabled OFF=No effect SW1 - Dip switch 2 It chooses whether the unit will operate in condominium mode or not : ON=Condominium OFF=No effect SW1 - Dip switch 3 It determines the operation mode of the optical barrier : ON=Photostop OFF=Photo-cell F1 ­ Mains power fuse (5A) It disconnects the electronic unit from the power supply mains in case of short-circuit or electric current consumption anomalies. F2 ­ Low voltage fuse (2A) It protects the electronic unit in case of short circuits or overcurrents on photo-cells, electric lock or any other accessory devices connected to the 24 Vac power supply. Power regulator The electronic unit is pre-set for the optional connection of an accessory card called "power regulator". By means of this card the power supplied to the motors can be reduced. Caution: In ca se failure or anomaly of the power regulator card the motors may operate at their maximum power value. This is why n° 7 note in the previous chapter "limits to use" must absolutely be put into practice. Starting of maximum start up power When any of the motors starts the unit supplies the maximum power value for approx. Subsequently the unit's power regulator card, if present, operates. this particular feature allows to overcome the high negative torque at the motors' start. Radioreceiver The electronic unit is pre-set for the optional connection of an accessory radio receiver card allowing remote control of the gate by means of the radio transmitter. The channel 1 of the radio receiver card ends with a non-polarized electric contact (relay) directly connected to the start input. The channel 2 of the radio receiver card ends with a non-polarized electric contact (relay) directly connected to the 2nd radio channel output. This output is usually connected to the pedestrian start input, although it may be used also for other applications. Quick flashing light : it signals the opening phase Slow flashing light : it signals the closing phase The blinker is off when the gate is blocked in pause before the closure phase. Work time The motors' work time is controlled by two independent digital timers. For the automation system to work properly the operating time value to be set must be slightly (min. ) above the gate's actual work time. If any command interrupts the wing's travel before its end, the Timer stops and the elapsed time is stored in memory. [. . . ] The operating cycle is complete only when the closing motion has ended. If a start command is supplied while the gate opens, the command will have no effect. If a start command is supplied while the gate closes, the gate will stop and reverse its motion after approx. If a start command is supplied during the pause period, the period will be reset and the automatic closure will start later. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DUCATI CTR19

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DUCATI CTR19 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag