User manual EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I. We hope that this EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I user guide will be useful to you.

Lastmanuals help download the user guide EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I.


Mode d'emploi EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I
Download
Manual abstract: user guide EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION & OWNER'S MANUAL THE EAGLE POWER I BATTERY BACK UP PHONE (818) 764-6690 / TOLL FREE (800) 708-8848 PRE INSTALLATION INSTRUCTIONS ! CAUTION! ! CAUTION! BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY AND CAREFULLY FOLLOW ALL THE OPERATION INSTRUCTIONS. USE ONE POWER I BATTERY BACK-UP SYSTEM PER EACH GATE OPERATOR. DO NOT ATTEMPT TO CONNECT MORE THAN ONE OPERATOR PER POWER I SYSTEM. The Eagle-Power I Battery Back up is designed to provide back up power to a gate operator when the main AC supply voltage is interrupted or disconnected. [. . . ] All cycle estimates are based on properly installed gates and operators. (3) INSTALLATION OF THE EAGLE POWER I CONNECTING THE AC LINE VOLTAGE: Electrically, the Power I is wired in series with the incoming AC supply from the breaker box to the operator. The connector labeled "AC In" is connected to the main AC supply. The "AC Out" is connected to the operator. Connect the incoming AC line to the AC In as follows: L - AC Line In (Live): Black N - AC neutral (Common): White G - AC Ground (Earth): Green Connect the outgoing AC line to the AC Out as follows: L - AC Line Out: Black N - AC neutral: White G - AC Ground: Green Refer to the installation manual provided with operator for the proper connections to the operator APPLYING THE POWER AND CONNECTING THE SYSTEM RELAY With the power to the operator and breaker box turned off and all of the AC line connections are complete, install the provided relay. After 5 to 10 seconds the green inverter light will turn on. Then run the operator with the main breaker off to test the power I. When testing is completed, turn on the breaker and the green inverter light will go off, then charger green or yellow light will go on. FOR HOLD OPEN APPLICATION Connect the two orange terminals to the "exit open" on the operator. Using this connection will immediatly open the gate upon power failure. Gate operator will resume normal operation when power is resumed. Eagle recommends surge protection be installed on the incoming 110 AC Line to the battery back-up unit. IMPORTANT! (4) INSIDE OF THE EAGLE POWER I INVERTER REAR BATTERY SUB-PANEL RELAY SOCKET TIMER RED WIRES (+) + L HOLD OPEN COM N/O _+ AC OUT NG L AC IN NG + FRONT BATTERY BLACK WIRES (-) (5) MOUNTING THE EAGLE POWER PS INSTALLATION OF THE E-I I 17 1/2" MOUNTING BRACKETS 12 3/8" REAR VIEW OF CONTROL BOX Mounting Holes 3/8" Diameter 7" (OC) MOUNTING BRACKETS 3" 15" 16 1/2" (OC) (Drawing N. T. S. ) (6) SPECIFICATIONS & WARRANTY TECHNICAL SPECIFICATIONS INPUT VOLTAGE: BATTERY: RECHARGE TIME: OUTPUT VOLTAGE: OUTPUT FREQUENCY: OUTPUT CURRANT: SURGE CURRANT: AC OUTPUT POWER: SURGE POWER: RELAY OUTPUTS: 105 - 125 VAC 12VDC / 70AH 8 HOURS 115 VAC 60 Hz 5 AMPS 9 AMPS 800 WATTS 1600 WATTS 2 AMPS ! CAUTION! DO NOT EXCEED THE OUTPUT CAPACITY OF THE POWER I. [. . . ] In no event shall Eagle's liability for breach of warranty, breech of contract, negligence or strict liability exceed the cost of this product hereby. No person is authorized to assume for Eagle any other liability in connection with the sale of this product. For Further Information: Phone (800) 708-8848 / Fax (818) 764-6869 (7) [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EAGLE ACCESS CONTROL SYSTEMS EAGLE POWER I will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag