User manual EATON ELLIPSE PRO 1600 FR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EATON ELLIPSE PRO 1600 FR. We hope that this EATON ELLIPSE PRO 1600 FR user guide will be useful to you.

Lastmanuals help download the user guide EATON ELLIPSE PRO 1600 FR.


Mode d'emploi EATON ELLIPSE PRO 1600 FR
Download
Manual abstract: user guide EATON ELLIPSE PRO 1600 FR

Detailed instructions for use are in the User's Guide.

[. . . ] 5 kV / 1 kV 3 kA 1500 Vac , 50 Hz 3000 Vac , 50 Hz 1000 Vac , 50 Hz 250 Vac 430 Vac 405 Joules 1200 1600 Dielectric isolation • AC Ground • AC / TEL • Tel / Ground Temporary overvoltage (TOV) • Uc • Ut Energy dissipation 614-06817-00 5 1. Operating conditions English •  his product is an Uninterruptible Power Supply (UPS) for computers and their T peripherals, television sets, stereo systems and video recorders. It must not be used to supply other electrical equipment (lighting, heating, household appliances, etc. Description 6 ON/OFF button for the AVR 6 % Min Hz kVA kW battery backup outlets 7 8 7 Scroll down 8 ASR LED LCD 10 9 13 11 12 14 15 16 17 9 10 11 12 13 14 15 16 17 UPS ON AVR mode Battery mode Internal fault Output load level Battery level Input measurements Output measurements Measuring unit Outlets 650 / 850 1200 / 1600 18 18 Surge protection outlets 19 Battery backup outlets 20 Protection (circuit breaker) Out In et Mode Intern m / Netwo rk Master 19 18 20 EcoControl 19 20 6 614-06817-00 3. [. . . ] Threshold setup A default setup ensures the correct operation of the EcoControl function. However, depending on the consumption of the main load, the trigger threshold of the EcoControl function may have to be modified using the configuration software supplied with the UPS: •  irst, make sure that the function is activated in the "EcoControl Function" tab of the F configuration tool. € f the peripherals connected to the EcoControl outlets do not switch off when the main I load is not in normal operation (ex: when in standby mode), the detection threshold value must be set to High. € f the rated consumption level of the main load is low and the EcoControl outlets shut I down when the main load is operating normally, the detection threshold value must be set to Low. UPS setting through the LCD English Release scroll down button to select menu 5s 2s 2s 2s 2s Output voltage Input voltage tolerance EcoControl Alarm (165 - 264 V) (150 - 284 V) Example of setting 10s Save the new value 5s 5s l LCD shut off if no activity for 3 minutes. Operation Battery charge The UPS charges the battery as soon as it is connected to the AC outlet, whether button 6 is pressed or not. When used for the first time, the battery will only provide its maximum performance after it has been charged for 8 hours. It is recommended that the UPS be permanently connected to the AC power supply to ensure the best possible performance. Switching-on the UPS Press button 6 for about 1 second. Surge protection outlets 18 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 4 is plugged in. Battery backup outlets 19 Equipment connected to these outlets is supplied as soon as button 6 turns green (see figure D). These outlets can be turned on even if the UPS is not connected to AC power (button 6 flashes). 8 614-06817-00 AC-power disturbance • f AC power is disturbed or fails, the UPS continues to operate on battery power. In normal mode, the audible alarm beeps every ten seconds, then every three seconds when the end of battery backup time is near. In silent mode, the audible alarm simply beeps once when the UPS transfers to battery power. € If the power outage lasts longer than the battery backup time, the UPS shuts down  and automatically restarts when power is restored. Following a complete discharge, a few hours are required to recharge the battery back to full backup time. surge protection: All outlets include surge protection. Shutdown of the battery backup outlets 19 Press button 6 for more than two seconds. Troubleshooting (For further information, visit the www. [. . . ] 5 • A fault has occurred on the UPS. The battery backup outlets 19 are no longer supplied. • Surge protection is no longer provided. € EcoControl function is not activated or not properly set. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EATON ELLIPSE PRO 1600 FR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EATON ELLIPSE PRO 1600 FR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag