User manual ECHO W1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ECHO W1. We hope that this ECHO W1 user guide will be useful to you.

Lastmanuals help download the user guide ECHO W1.


Mode d'emploi ECHO W1
Download
Manual abstract: user guide ECHO W1

Detailed instructions for use are in the User's Guide.

[. . . ] The symbol ofp means this function is for ECHO-W2 only; all descriptions with this symbol are not suitable for ECHO-W1 A. Refer to the TEST section to testing the installation before tighten the sensor band with a screwdriver. (Fig. Fix the excess sensor band 11 by thrusting it into the band carrier 12 . The main unit has a "Slide On/Off Detecting Switch " (patents pending) to turn ON/OFF the power of the wireless receiver. [. . . ] It is calculated from the DS divided by the TM. The average data counted is from the last RESET to current point. It displays "0. 0" when TM is less than 4 sec. , and is updated by about one second when TM is over 4 seconds. It displays an "Err" symbol when either the TM is over 100 hours or the DS is over 1, 000km (or miles). Reset the unit in order to restart. All descriptions are similar as the Lubrication Reminder except the word of Maintenance instead of Lubrication and the symbol " " shall be replaced by the symbol " ". Remarks: All functions' data are updated about one second. Sensor with Transmitter: No Contact Magnet sensor with Wireless Transmitter. Suitable Fork Size: 12mm to 50mm& (0. 5" to 2. 0" &) Forks. Wireless Sensing Distance: 55cm (1. 8 feet) between the transmitter and the main unit. Cross-Talking Interference: Within 40 cm (15. 8"), no interference by 2 bicycles carrying similar cycle computers, even when ridden side by side. Wheel Circumference Setting: 1mm - 3999mm (1mm increment) Operation Temperature: 0°C ~ 50°C (32°F ~ 122°F) Storage Temperature: - 10°C ~ 60°C (14°F ~ 140°F) Main Unit Battery Power: 3V battery x 1 (CR2032), battery operating life is about 2 years. (Based on an average of 1. 5 hours use per day) Transmitter Battery Power: 1. 5V battery x 1 (typical LR44). About 24, 000km/15, 000 miles riding distance or 2 years battery operating life. (The original factory-attached battery life may be shorter than this period due to shipping and storage time). Dimensions and Weight Main Unit: 44. 0 x 53. 0 x 19. 3mm/31. 5g Transmitter: 20. 0mm& x 48. 0mm/14. 1g DS: Trip Distance 0. 00 ­ 999. 99 Km or Miles +/- 0. 1% The DS function accumulates the distance data from the last RESET operation as long as the bike is being ridden. * The specifications and designs may be changed without notice. I NDEX: MEANS PRESS BUTTON N MORE THAN 2 SECONDS. MEANS PRESS BUTTON N QUICKLY {N=KEYNUMBER: MODE Button. } p LUBRICATION or MAINTENANCE REMINDER SETTING (For W2 only) p BIKE 1 or BIKE 2 SELECTION (For W2 only) (Fig. BATTERY CHANGE FOR SENSOR (TRANSMITTER) a). The patent-pending transmitter circuit is designed to reduce power consumption; a 1. 5V battery (typically an LR44) can operate for over 24, 000km (15, 000miles) riding distance or 2 years. Replace a new battery when the transmitter's battery power is nearly exhausted, otherwise the transmission power of the wheel signal will be weak, causing the main unit to display unstable data. Replace with a new LR44 battery 16 with the positive (+) pole toward the sensor cap 10 . 1) INITIATE THE COMPUTER (ALL CLEAR) EN 1. A battery is already loaded in the main unit when purchased. [. . . ] 6 ) till the LCD digit is blanked, then release it. Hold down the MODE button DS, TM and MX data from stored values to zero. It cannot reset ODO, T-TM, , T-ODO, Lubrication and Maintenance Reminders. p RE-LOAD LUBRICATION OR MAINTENANCE REMINDER AFTER MAINTAINED (For W2 only) In order to avoid the Lubrication or Maintenance reminder be cleared by the RESET operation, be follow the following procedures to RE-LOAD the previous setting value after you finish either function. Change it to the desired to display the previous setting value and clear the reminder symbol. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ECHO W1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ECHO W1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag