User manual EDIROL S-0808 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EDIROL S-0808. We hope that this EDIROL S-0808 user guide will be useful to you.

Lastmanuals help download the user guide EDIROL S-0808.


Mode d'emploi EDIROL S-0808
Download

You may also download the following manuals related to this product:

   EDIROL S-0808 FEATURES AND BENEFITS (1845 ko)

Manual abstract: user guide EDIROL S-0808BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Eliminate the need for direct boxes with inputs 5 - 8 supporting balanced TRS and as well as 7 and 8 supporting Hi-Z from guitars. S-4000R Remote Controller Dedicated remote controller for the Digital Snake series. Gain level, pad and phantom power are remotely controllable. S-4000RCS Remote Control Software Dedicated remote control sof tware for the Digital Snake series. Monitor all 40 channels and control gain levels, pad, and phantom power from your PC. DC input for External Battery. [. . . ] The Digital Snake advantage. Configure for a variety of applications and environments. Connectivity is simple enabling rapid system changes, expansion and flexibility. Simple Mobile Broadcasting System (8in/8out) Event/Concert System with Battery-powered I/O Units (26in/42out) Stage FOH Mixing Console 10in Field Location Broadcast Truck (OB Van) 1~8ch S-0808 S-4000R 1~8ch DC BATTERY 9~16ch S-0808 9~16ch DC BATTERY 100m 100m M-400 or M-380 10out Portable Recorder, etc S-0816 For Recording 16out 8in S-0808 8out 8ch S-4000M 8ch POWER 100m POWER S-0808 8out 8in Simple system setup using a pair of S-0808s. The S-4000M in a Broadcast Truck (OB Van) provides power to the remote location. Control the remote inputs using the S-4000R. Small concert/event configuration using two battery-powered I/O units enable convenience in placing the talent where AC power is not necessarily available. Mix using your choice of V-Mixer. Broadcasting System with Multiple Locations (32in/8out) Live Stage Mixing System (32in/32out) 100m 1~8ch S-0808 1~8ch 9~16ch S-0808 1~8ch 17~24ch S-0808 1~8ch 25~32ch S-0808 1~8ch Shooting Area D Shooting Area C Shooting Area B Shooting Area A Stage Control Room FOH S-4000R 1~8ch S-0808 1~32ch 1~8ch 9~16ch S-0808 9~16ch 17~24ch S-0808 17~24ch 25~32ch S-0808 100m 10out S-4000M POWER 100m M-400 or M-380 POWER Mixing Console POWER S-4000M POWER S-4000H 1~8ch 10in POWER POWER POWER 25~32ch POWER This system allows I/O to be place in 4 separate locations using S-0808s. The signals from the 4 units are merged by the S-4000M as it travels to the S-4000H breakout location. Power to each of the S-0808s is supplied by the embedded power over REAC in the S-4000M. This system enables the placement of S-0808 units around a stage conveniently located by the drum riser, keyboards, background vocals, etc. S-4000M Merge Unit Up to 4 REAC devices can be merged to a single RE AC stream. Power can also be provided to each S-0808 using REAC Embedded Power technology. M-400/M-380 Live Mixing Console The Live Mixing Console which uses the Digital Snake series as I/O units. 48 input/18 bus/8 matrix/56 output mixing capability allows use at a large variety of live events. M-380 S-0808 Specifications Number of Channels AD/DA Conversion Frequency Response Total Harmonic Distortion + Noise Dynamic Range Cross Talk Nominal Input Level PAD Input Impedance Nominal Output Level Output Impedance Recommended Load Impedance Residual Noise Level (IHF-A, typ. ) 8 in 8 out Sample Rate: 96. 0 kHz/48. 0kHz/44. 1kHz Signal Processing: 24 bits -2 dB/+0 dB (@ +4 dBu, 20 Hz to 20 kHz) 0. 04 % or less (Pad: On, Input Gain: +4 dBu, 22 Hz to 20 kHz) 110 dB -80 dB or less (Input Gain: +4 dBu, typ. ) -65 to -10 dBu (PAD: Off), -45 to +10 dBu (PAD: On) (1 dB step, Max. +28 dBu) 20 dB On/Off 7 k ohms +4 dBu, Max. +22 dBu 600 ohms 10 k ohms or greater -80 dBu or less *2: TRS takes priority if XLR and TRS are simultaneously input to INPUT 5-8. Equivalent Input Noise Level (E. I. N. ) -128 dB Network Latency 375 microseconds when using REAC cable only *1 (AD - REAC - DA Latency: about 1. 2 ms) Input x 8 (XLR type, balanced, phantom power, INPUT 1-8) Input x 2 (TRS type, balanced, INPUT 5/6) *2 Input x 2 (TRS type, balanced, with Hi-Z switch, INPUT 7/8) *2, *3 Output x 8 (XLR type, balanced) REAC EMBEDDED POWER x 1 (RJ-45 EtherCon type) REMOTE x 1 (RS-232C, DB-9 type), DC IN x 1 (XLR 4pin type) REAC EMBEDDED POWER or External Battery (DC 12V - 18V) 26W (DC 12V) +48 V/14 mA (each input, remote controlled) 220. 0 (W) x 176. 0 (D) x 156. 6 (H) mm, 8-11/16 (W) x 6-15/16 (D) x 6-3/16 (H) inches 2. 9 kg, 6 lbs 7 oz Battery Plate Holder and Fastening Screws (8 pcs), REAC Connector Covers x 1 Ferrite Core x 2, Fastening Screw x 4, Owner's Manual (0 dBu = 0. 775 Vrms) Connectors Power Supply Power Consumption Phantom Power Dimensions Weight Accessories *1: XLR connector 1: GND, 2: HOT, 3: COLD *3: TRS of INPUT 7/8 turns to unbalanced when Hi-Z is turn on. * When a REAC Splitter S-4000-SP or a switching hub is used in-line with REAC cables, the network latency will increase by the amount of processing delay introduced by the splitting device itself. The actual delay is dependant upon the specifications of the splitting device, though the maximum delay amount for a single splitting device should be about 200 microseconds. S-0808 Dimensions 11 Options Unit = mm 156. 6 35 110. 6 204 220 40Ch I/O Modular Rack 8in/32out FOH Unit REAC Cable (20 meters) REAC Cable (100 meters) with Reel REAC Optical Converter S-4000S-0832 S-4000H Nex t generation digital a u d i o t r a n s f e r s y s te m Digital Snake. This modular rack can be customized with a choice of high quality I/O cards. FOH I/O unit that uses D-Sub connectors. Bundled cable protector. SC-W20F 20 meter premium RE AC cable. W100S-R Reel-mounted 100 meter cable. S-OPT Converter for transmitting REAC through optical cable. M a x i m u m tr a n s m i t t a b l e distance is 2 km. [. . . ] We're actively seeking ways to maintain harmony with the environment. (ISO=International Standardization Organization: an organization for the promotion of standardization of international units and terms. They provide different categories of certification: ISO9001 Series certification is a product quality certification for products that undergo a certain level of quality control from the design stage to the after service stage; ISO14001 Series certification is for environment-related standards. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EDIROL S-0808

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EDIROL S-0808 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag