User manual EFD 2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EFD 2000. We hope that this EFD 2000 user guide will be useful to you.

Lastmanuals help download the user guide EFD 2000.


Mode d'emploi EFD 2000
Download
Manual abstract: user guide EFD 2000

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Guide 2000XL Series Digital Dispensers 2000XL · 2000XL-PR5-15 · 2000XL-CA ® Pressure Cell Select Time Set Fast Slow A NORDSON COMPANY STEADY RUN Vacuum SETUP CYCLE Vacuum Pressure Run Setup Steady Teach Fast Slow Time Set Pressure Time STOP ® In the US: 800-556-3484 A NORDSON COMPANY In the UK: 0800 585733 In Mexico: 001-800-556-3484 Introduction The 2000XL Series dispensers provide years of trouble-free, productive service. This Operating Guide will help you maximize the usefulness of your new dispenser. Please spend a few minutes to become familiar with the controls and features of your new dispenser. Follow our recommended testing procedures. [. . . ] Press RUN/SETUP and toggle back to the SETUP mode. Press the TIME SET buttons and change the time to 2. 30 seconds. Go back to RUN, press the foot pedal, and the dispenser will make a deposit approximately twice the size of the first one. Don't Forget! Changes to the time settings can be made only when the mode of operation is SETUP. RUN mode locks out TIME SET and TEACH control buttons. Use this to protect the setup from inadvertent changes. Pressing STEADY/TEACH in SETUP mode will clear all time settings within cell. STOP immediately terminates the current dispense cycle. Use only dry, clean, filtered air. Pressure--changes deposit size. The dispenser should be in the RUN mode, the TIME setting should be 2. 30 seconds and the dispensing pressure should be 20 psi (1. 4 bar). Increasing the pressure will result in larger deposits, decreasing the pressure will result in smaller deposits. Try this now and observe the results. Tip Size--changes deposit size. Tip size also affects deposit size. Without changing the TIME or PRESSURE setting, try different tips and observe the results. ¤ If you have any questions at this point, please call us now. In the US, call 800-556-3484 (Between 8:30 am and 6:00 pm eastern time. ) In Mexico, call 001-800-556-3484. In the UK, ring free 0800 585733. Advanced Dispensing System TM If you dispense thick fluids, several problems may occur. First, the repetitive air cycles can bore tunnels through non-leveling fluids, causing spitting and inconsistent deposits. Second, thick fluids contain trapped air that leads to drooling and oozing. These problems are eliminated by using the SmoothFlowTM piston. That's because the white pistons prevent tunneling by providing a barrier to the pulsed-air cycles, and prevent oozing by responding to the pressure of trapped air with a slight suck-back movement after the dispense cycle. The white piston is used for most fluids. However, if you are applying RTV silicone and find that the piston bounces and causes stringing, switch to the orange, flat wall piston. The SmoothFlowTM pistons make barrel filling easier, too. As you load the fluid in, air is trapped in the bottom and throughout the fluid. Simply insert a SmoothFlowTM piston and gently press down on the fluid as far as possible. [. . . ] hose, male quick-connect and safety clip. size 3cc 5cc 10cc 30cc/55cc with 3-ft hose 1000Y5148 1000Y5149 1000Y5150 1000Y5152 with 6-ft hose 1000Y5148-6 1000Y5149-6 1000Y5150-6 1000Y5152-6 General purpose precision tips All EFD dispensing tips incorporate the unique SafetyLokTM color-coded polypropylene hubs. Conveniently packaged (50) tips per see-through box for easy part identification. gage 14 15 18 20 21 22 23 25 27 30 ID . 061" . 054" . 033" . 024" . 020" . 016" . 013" . 010" . 008" . 006" 1/2" length 5114-B 5115-B 5118-B 5120-B 5121-B 5122-B 5123-B 5125-B 5127-B 5130-B hub color olive amber green pink purple blue orange red clear lavender Each box contains the same quantity of barrels and pistons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EFD 2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EFD 2000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag