User manual EFD 615DT 626DT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EFD 615DT 626DT. We hope that this EFD 615DT 626DT user guide will be useful to you.

Lastmanuals help download the user guide EFD 615DT 626DT.


Mode d'emploi EFD 615DT 626DT
Download
Manual abstract: user guide EFD 615DT 626DT

Detailed instructions for use are in the User's Guide.

[. . . ] CHECK all reservoir components regularly and replace any worn or damaged parts with only EFD supplied or approved parts. BE SURE that all dispensing equipment and accessories are rated to withstand the maximum operating pressure of the reservoir. Personal Protective Equipment Wear all protective eyewear, gloves, clothing and respirator as recommended by the manufacturer of the fluid used. Continued on next page Safety Warnings 3 System Pressure NEVER exceed the maximum reservoir pressure of 6. 9 bar gauge (100 psi). The maximum supply pressure to the reservoir regulator must not exceed 10. 4 bar gauge (150 psi). [. . . ] BE SURE all fluid connections to the reservoir are properly secured. Examine all tubing for cuts, wear, bulges and leaks. If any of these conditions exist, replace the tubing immediately with EFD supplied or approved tubing. BE SURE that the fluid to be dispensed is compatible with the tubing. Contact the fluid manufacturer and confirm that the fluid is compatible with the tubing material specified on page 15 of this manual. BE SURE that the tubing will not be exposed to operating temperatures in excess of 50 °C (122 °F) or below 0 °C (32 °F) in the application. Safety Warnings 5 615DT Exploded View 1 2 6 3 7 4 5 4 9 10 14 8 12 11 13 6 615DT Exploded View 615DT Specifications Capacity: Maximum Operating Pressure: Weight: Height: Diameter (Cover Maximum): 1 litre 6. 9 bar (100 psi) 3. 0 kg (6. 60 lbs) 350 mm (13. 75 inches) 172 mm (6. 75 inches) Maximum Operating Temperature: 50 °C (122 °F) 615DT Replacement Parts Part number Description 1. 61506 61506V 61506E Female quick-connect Fitting - 1/4 NPT F x 1/8 NPT M Precision regulator 0-100 psi (0-6. 9 bar) Precision regulator 0-15 psi (0-1. 0 bar) 1/8 NPT M x 1/8 NPT M Tee fitting - 1/8 NPT F Gauge 0-100 psi (0-6. 9 bar) Gauge 0-15 psi (0-1. 0 bar) Mini relief valve Fitting, bulkhead for 1/4" OD tube Knob Bolt Dowel pin Tank liner Stand Cover O-ring Buna (Standard) Cover O-ring Viton Cover O-ring EPR ® Quantity 1 1 1 2 1 1 1 1 1 3 3 3 4/box 1 1 615DT Specifications/Replacement Parts 7 626DT Exploded View 1 2 3 6 4 5 7 9 8 10 14 11 12 13 8 626DT Exploded View 626DT Specifications Capacity: Maximum Operating Pressure: Weight: Height: Diameter (Cover Maximum): 5 litre 6. 9 bar (100 psi) 9. 1 kg (20. 1 lbs) 413 mm (16. 25 inches) 251 mm (9. 85 inches) Maximum Operating Temperature: 50 °C (122 °F) 626DT Replacement Parts Part number Description 1. 62506 62506V 62506E Female quick-connect Fitting - 1/4 NPT F x 1/8 NPT M Precision regulator 0-100 psi (0-6. 9 bar) Precision regulator 0-15 psi (0-1. 0 bar) Fitting 1/4 NPT F x 1/8 NPT M Fitting 1/4 NPT M x 1/4 NPT M Gauge 0-100 psi (0-6. 9 bar) Gauge 0-15 psi (0-1. 0 bar) Fitting, bulkhead for 3/8" OD tube Fitting, reducer, 3/8" to 1/4" tube Air relief valve Knob Bolt Dowel pin Tank liner Cover O-ring Buna (Standard) Cover O-ring Viton Cover O-ring EPR ® Quantity 1 1 1 1 1 1 1 1 1 4 4 4/box 4/box 1 626DT Specifications/Replacement Parts 9 Pressure Relief Procedure To reduce the risk of bodily injury, including fluid splashing into the eyes, NEVER attempt to open the reservoir without first performing this procedure. (Figure 1) on the air input hose to 2. Hold the relief valve open until any hissing sounds end. Confirm that the indicated gauge pressure is zero . If the gauge reads zero, slowly release the cover clamps and remove the cover as shown in Figure 2. If the pressure gauge does not read zero after performing Steps 1 and 2, remove the air input hose from the air regulator and set the regulator pressure to zero. A hissing sound should be heard from the regulator during this step. Once the gauge reads zero, return to Step 3. Do not use the reservoir until the air relief valve is replaced. 10 Pressure Relief Procedure Input air tee #1116 shutoff valve exhaust pressurize Air input hose #2310S Air filter regulator #2000F756 Fluid feed tubing #2025 regulator Air relief valve Tank air ¤ EFD valve controller EFD valve Tank stand #61520 Proper ferrule assembly Figure 1. 615DT shown Input air tee #1116 shutoff valve exhaust pressurize Air input hose #2310S Air input hose #2310S Air filter regulator #2000F756 ¤ Tank air regulator Air relief valve EFD valve controller Fluid feed tubing #2025 EFD valve Figure 1. 626DT shown Pressure Relief Procedure 11 Setup 1. Install the input air tee into the EFD five-micron filter regulator supplied with the ValveMateTM controller. If no air filter regulator is available, specify #2000F755. (For cyanoacrylates, add coalescing filter regulator element #756FLT. ) 2. Set up the EFD dispense valve and controller as described in their operating manuals. [. . . ] Follow Setup steps 6-8 to refill, then close the air relief valve and slide the shutoff valve to the "pressurize" position. Note: When pressurized, it is normal to hear a hissing sound coming from the regulator. This is due to the precision constant-bleed regulator feature. Figure 4 Setup 13 Wetted Materials List The following materials come in contact with the fluid dispensed during normal use: 1. Polyethylene (fluid feed tubing and tank liner) 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EFD 615DT 626DT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EFD 615DT 626DT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag