User manual EFD 7090

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EFD 7090. We hope that this EFD 7090 user guide will be useful to you.

Lastmanuals help download the user guide EFD 7090.


Mode d'emploi EFD 7090
Download
Manual abstract: user guide EFD 7090

Detailed instructions for use are in the User's Guide.

[. . . ] Time is displayed in real time from . 001 to 99. 9 seconds. In settings less than 1. 0 seconds, the decimal will not show. Pressure is identified with a flashing "P" for pounds per square inch or an "A" for atmosphere in the left display segment. Motor speed is identified with a rotating cursor in the left display segment and voltage in the two right segments. [. . . ] Continue dispensing until valve is purged of all air. To determine deposit size, press and hold the program button until the display flashes bright to dim. The valve will begin to dispense while accumulating time on the display. Release the cycle button, then press again; time will be added to the prior sum. Press the program button to save the time. Press the cycle button or optional foot pedal to initiate a complete cycle. Each press on the button or pedal will repeat the same timed deposit. Pressing the button or pedal while the valve is dispensing will stop the cycle. Press up/down buttons to make fine adjustments to the time. Press the buttons momentarily to single step, or press and hold to scroll the time display. Press the toggle button twice to enter the motor speed mode (24 will show on the display). Press the down button to reduce the voltage to 15. Press the cycle button and notice the change in dispensing rate. Press the up button to return to normal operating speed of 24. Turn the key lock to the locked position. Notice that the program, up and down buttons are not operative. The cycle, time override and toggle buttons, however, do function in the locked mode. 9 / Trial Run Operation Review Reservoir Pressure Setting Air pressure is used to maintain a constant flow of fluid from the reservoir to the auger. In general, 8 to 12 psi (0. 5 bar to 0. 8 bar) is enough pressure for solder paste. Some experimentation may be necessary to find the correct pressure for other fluids. Set the pressure so there is enough to keep the auger primed at all times, but not so much pressure that the fluid is forced past the auger when the valve is off. Begin by setting the pressure at 10 psi (0. 68 bar). Operate the valve in time override mode without a dispensing tip installed until material flows from the outlet. [. . . ] 79012 1/8 NPT x 1/4 barb - low profile 1/8 NPT x 1/4 barb 90° - brass Motor power harness receptacle (not shown) Power supply Exhaust muffler Power switch Key lock switch Fuse ­ AC power Optional foot pedal (not included) Fuse ­ output protection (2) 10 15 8 12 3 1 2 3 18 5 9 20 2 14 12 11 4 16 17 6 1 Input Air Regulated Air 15 / Schematic and Replacement Parts List EFD ONE YEAR LIMITED WARRANTY All components of EFD ValveMate controllers are warranted for one year from date of purchase to be free from defects in material and workmanship (but not against damage caused by misuse, abrasion, corrosion, negligence, accident, faulty installation or by dispensing material incompatible with equipment) when the equipment is installed and operated in accordance with factory recommendations and instructions. EFD will repair or replace free of charge any part of the equipment thus found to be defective, on authorized return of the part prepaid to our factory during the warranty period. In no event shall any liability or obligation of EFD arising from this warranty exceed the purchase price of the equipment. This warranty is valid only when oil-free, clean, dry, filtered air is used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EFD 7090

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EFD 7090 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag