User manual EFD PM6500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EFD PM6500. We hope that this EFD PM6500 user guide will be useful to you.

Lastmanuals help download the user guide EFD PM6500.


Mode d'emploi EFD PM6500
Download

You may also download the following manuals related to this product:

   EFD PM6500 QUICK START GUIDE (80 ko)

Manual abstract: user guide EFD PM6500

Detailed instructions for use are in the User's Guide.

[. . . ] Our goal is to build not only the finest equipment and components, but also to build long-term customer relationships founded on superb quality, service, value and trust. Peter Lambert, President 2 Contents Safety. Back Cover This manual is for the express and sole use of EFD ProcessMate purchasers and users, and no portion of it may be reproduced in any form. 3 Safety Introduction Read and follow these safety instructions. Task- and equipment-specific warnings, cautions and instructions are included in equipment documentation where appropriate. Qualified Personnel Equipment owners are responsible for making sure that EFD equipment is installed, operated and serviced by qualified personnel. [. . . ] Connect the power cord into your local power source. · · Connect Air Input NOTE: Clean, dry, filtered factory air is required to meet the warranty. If your air supply is not filtered, order the EFD five micron filter regulator (EFD part# 2000F755). · · · · Push one end of the air input hose into the input fitting on the back of the ProcessMate. Connect the other end of the hose to your plant air supply. Set plant air supply within 80 to 100 psi (5. 5 to 6. 9 bar). DO NOT exceed 110 psi (7. 5 bar) or damage to the unit may occur. Getting Started Connect Thermocouple 4 5 6 · · Plug K-type thermocouple lead into the back panel of ProcessMate. Connect the other end of the lead to process hardware. *Option: Can route thermocouple lead with either air line tubing inside insulation. See directions below. NOTE: Longer Thermocouple leads may be used when required. These are available from a variety of sources in many lengths. Only K-Type thermocouple leads should be used with the ProcessMate. Using a different type will result in incorrect temperatures. Attach Process Feed Lines · · Slide insulation over cold process feed line. Slide insulation over hot process feed line. *Option: Can route thermocouple lead with either hot or cold process feed line. · · Insert cold process feed line into the cold process fitting. Insert hot process feed line into the hot process fitting. Connect Exhaust Mufflers · Insert a muffler into each exhaust port for both cold and hot feed exhausts. NOTE: Tubing can be purchased as an accessory to route for remote exhaust in lieu of mufflers. 9 Features & Controls: Front & Rear Panels Digital display Power switch Air switch Flow control knob Air input Power cord Thermocouple to Exhaust feed line to Exhaust feed line Cold process feed line Hot process feed line CMW No. 1 display STOP OUT Temperature unit Alarm output indicator Level key No. 2 display Mode key Up/Down keys 10 Front Panel Digital Display Digital Display Level key Mode key No. 2 display Use to access advanced features of the controller. (Refer to manufacturer's documentation supplied with unit. ) Use to access advanced features of the controller (Refer to manufacturer's documentation supplied with unit. ) Actual temperature as measured by the thermocouple. Process temperature set point. Up/down keys Use the keys to change the temperature set point value displayed on the No. Al CMW STOP OUT Alarm indicator light--this will light up whenever the unit is adding cold air to the process. Communications writing enable/disable indicator lights Control stop indicator Control output 1 & 2 indicators Advanced features NOT used by ProcessMate Change from Centigrade to Fahrenheit · · · · Hold down the Level Key for 3 seconds. Press the Up arrow key to change from C to F or vice-versa. Return to the Temperature Display by holding the Level Key for 3 seconds Air Settings OFF (Center) MAX Air Stops all air from flowing through the unit. [. . . ] Within the period of this warranty, EFD will repair or replace free of charge any part of the equipment thus found to be defective, on authorized return of the part prepaid to our factory during the warranty period. In no event shall any liability or obligation of EFD arising from this warranty exceed the purchase price of the equipment. Before using, user shall determine the suitability of the product for his intended use, and user assumes all risk and liability whatsoever in connection therewith. This warranty is valid only when clean, dry, filtered air is used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EFD PM6500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EFD PM6500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag