User manual EFD ULTRA 325 TT QUICK START GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EFD ULTRA 325 TT. We hope that this EFD ULTRA 325 TT user guide will be useful to you.

Lastmanuals help download the user guide EFD ULTRA 325 TT.


Mode d'emploi EFD ULTRA 325 TT
Download
Manual abstract: user guide EFD ULTRA 325 TTQUICK START GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] The height sensor is attached to the backside of the Z-plate. This will allow enough room for the dispense tip to reach the parts without obstruction from the probe. To make the required adjustment, loosen the probe hold-down screw and slide probe either downwards or upwards. Hand tighten only; do not overtighten probe hold down screw or it will deform the probe. [. . . ] Tap Discover and wait for Socket #1 to appear in the Device list. When the Security screen opens, type "1234" and press OK. (Do not check "Add to trusted device list". ) Wait for the message "Connection established to selected device". Return to the Main screen, select Setup and the message "Dispenser is about to Home" will display. Tap OK to home the machine. Air 2 Pulsed air line White (female) quick-connect P1 Use 6mm OD tubing to connect the air to the main air input on the back of the machine. It is important that dry, clean, filtered air is used. It is recommended that either the 2000F755TT (5 micron filter regulator) or 2000F756TT (includes coalescing filter) be incorporated between the factory air supply and the Ultra TT System. 2000F755TT or 2000F756TT Air input hose Step 3: Single Air Input Valve Attach the valve to the appropriate valve bracket. Install the valve bracket onto the machine. Attach pulsed-air line to the P1 connector on top of the Z-head. Fluid reservoir air is connected to P2 or to auxiliary air connector on top of the Z-head. The fluid reservoir tank should be placed to the side of the machine or if using cartridges, attached to the T-slots on the Z-plate. To pressurized reservoir or cartridge Step 3: Auger Valve Attach the 790 auger valve to the auger valve bracket (#700806). Install the valve bracket onto the machine. Barrel reservoir air is connected to the P2 connector on top of the Z-head. The brown (+) lead is connected into Terminal 1 and the white (-) lead is connected to terminal 2 of the (4) position connector on top of the Z-head. Fluid feed hose 5 0 20 I/O Dispense Head Terminal 1 HS Terminal 2 I/O Dispense Head P1 P2 AUX AIR HS P1 P2 AUX AIR Black (male) quick-connect P2 752V-UHSS Valve P2 Tooling Plate 5 7 Install the EFD universal fixture plate (#7007-300 or #7007-500) or your own tooling plate. Note: Dimensional drawings for the Y-carriage can be found on the CD-ROM included with this machine. Caution: Failure to level your work-holding fixture may result in difficulties when programming. TTSERIES ® A NORDSON COMPANY Programming Follow the tutorial in the manual on the operations CD-ROM. This will teach you how to program all the essential elements of a fluid-dispensing program. Read the manual before attempting to teach your first program. If you have any questions regarding your new Ultra TT Automation Series system, please contact EFD or their authorized representative. 3 Helpful Hints ­ Pressure, Speed, Time and Tip Size control deposit size. Experiment with all four variables to determine ideal application. [. . . ] Changing pressure to compensate for reduced flow is the least reliable method to compensate for flow reduction. ­ Locate a point or mark on your part that you can use to orient the tip to when creating a new tip offset. ­ Always consider safety when working around automated equipment. ­ Remove the shipping bolt on top right-hand corner of Z-plate. For application assistance in the USA, call 800-556-3484. For EFD sales and service in over 30 countries, contact EFD USA or go to www. efd-inc. com/contact ® A NORDSON COMPANY EFD Inc. , a Nordson Company 977 Waterman Avenue East Providence, RI 02914-1342 USA telephone +1 401-434-1680 fax +1 401-431-0237 automation@efd-inc. com www. efd-inc. com/xyz Palm is a trademark of Palm, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EFD ULTRA 325 TT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EFD ULTRA 325 TT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag