User manual EINHELL RG-GP 6536

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EINHELL RG-GP 6536. We hope that this EINHELL RG-GP 6536 user guide will be useful to you.

Lastmanuals help download the user guide EINHELL RG-GP 6536.


Mode d'emploi EINHELL RG-GP 6536
Download

You may also download the following manuals related to this product:

   EINHELL RG-GP 6536 DATASHEET (258 ko)

Manual abstract: user guide EINHELL RG-GP 6536

Detailed instructions for use are in the User's Guide.

[. . . ] The operator is responsible for complying with local safety and installation regulations. (Ask an electrician if you are in any doubt. ) Consequential damage caused by flooded rooms in the event of the equipment suffering faults must be prevented by the user by means of suitable measures (for example installing alarm systems or a reserve pump, etc. In the event of a failure, repair work may only be carried out by an electrician or by ISC after sales service personnel. [. . . ] Install the intake and discharge lines in such a way that they do not exert any mechanical pressure on the equipment. The intake valve should be low enough in the water to ensure that if the water level falls, the equipment will not run dry. A leaking intake line will draw in air and therefore not draw in any water. 2 Connecting the discharge line The discharge line (min. 3/4") must be connected to the 1" female thread discharge line connector of the equipment either directly or with the aid of a threaded nipple. With the right couplings it is also possible, of course, to use a 1/2" delivery hose. the smaller delivery hose results in a lower delivery rate. During the priming operation, fully open any shutoff mechanisms (spray nozzles, valves, etc. ) in the pressure line so that the air can escape without obstruction. The pump is switched off automatically by the thermostat if overheating occurs and is switched on again automatically after cooling. Mains connection 230V ~ 50 Hz Power rating 650 W Pumping rate without non-return valve: 3750 l/h Pumping rate with non-return valve: 3450 l/h Max. Unscrew the coarse filter screw (6) and remove the coarse filter (8) together with the non-return valve (9) as shown in Figure 2. Now you can fill the pump housing with water via the coarse filter screw (6). Switch on the equipment with the power switch (3) - water can be suctioned in for up to 5 minutes (maximum suction height). After finishing the work, switch off the equipment with the power switch (3). Remove the coarse filter screw (6) and coarse filter (8) together with the non-return valve (9) (Figure 2). disassemble the coarse filter insert as shown in figure 3. Do not use abrasive cleaning agents or petrol to clean the coarse filter and the non-return valve. Clean the coarse filter and the non-return valve by tapping them on a flat surface. In cases of stubborn dirt, first clean with soapy water, then rinse with clear water and air-dry. 3 Storage If the pump is not going to be used for a long time or has to be removed for the winter months, rinse it out with water, empty it completely and allow it to dry. The equipment must be completely drained before it is subjected to frost. [. . . ] Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e. Connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of non-approved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e. Damage caused by the device being dropped) and normal wear resulting from proper operation of the device. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EINHELL RG-GP 6536

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EINHELL RG-GP 6536 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag