User manual EIZO ECLIENT 531LT-GR ADMINISTRATOR'S MANUALS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EIZO ECLIENT 531LT-GR. We hope that this EIZO ECLIENT 531LT-GR user guide will be useful to you.

Lastmanuals help download the user guide EIZO ECLIENT 531LT-GR.


Mode d'emploi EIZO ECLIENT 531LT-GR
Download

You may also download the following manuals related to this product:

   EIZO ECLIENT 531LT-GR BROCHURE (250 ko)

Manual abstract: user guide EIZO ECLIENT 531LT-GRADMINISTRATOR'S MANUALS

Detailed instructions for use are in the User's Guide.

[. . . ] For Microsoft Windows CE 2. 12 Version C LCD Monitor integrated Windows-based Terminal Touch Panel LCD Monitor integrated Windows-based Terminal Please confirm the version of the software built in eClient, and refer to the suited User's Manual (Refer to the User's Manual Version List on next page). This is the manual for the following software version. * Microsoft Windows CE: 2. 12 Rev. 3. 53 or later * Microsoft Terminal Server Client: Ver. 5. 60 or later * ICA Client: Ver. 6. 30 [Build 1078] or later User's Manual Version List A handling description changes with versions of the software built in eClient. Please NOTE · The version of software built in eClient can be checked with a [System]-[ICA] tab of [Terminal Properties]. OS: Microsoft Windows CE 2. 12 Software Microsoft Windows CE Manual Microsoft Windows Terminal Server Version 5. 60 or later Version 5. 60 or later Version 5. 51 or later ICA Client Software Version 6. 30 [Build1078] or later Version 6. 20 [Build992] or later Version 6. 20 [Build992] or later C (This Manual) B A 2. 12 Rev. 3. 53 or later 2. 12 Rev. 3. 51 or later 2. 12 Rev. 3. 50 or later English SAFETY SYMBOLS This manual uses the safety symbols below. Please read them carefully. WARNING Failure to abide by the information in a WARNING may result in serious injury and can be life threatening. CAUTION Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage. [. . . ] 5. Display the "Terminal Connection Manager" dialog box. Select the connection you want to modify. [Edit Connection] dialog box or [Edit Connection Details] is displayed. · For RDP Connection (Please see pages 35 to 39 for each setting. ) [Net Connections] tab. . . . . . . . Change connection settings to a WTS. [Application] tab. . . . . . . . . . . . . . . . Change a description of an application on a startup. Click [OK] to enable the settings. 4. ADDING & CHANGING A CONNETION NAME 53 English · For ICA Connection (Please see to pages 40 to 50 for each setting. ) [Server/Dial-In] tab . . . . . . . . . . . . . Either Server or Dial-In tab is displayed depending on the connection type. [Server] Tab (for LAN connection) To change the WTS / the public application to use [Dial-In] Tab (for Dial-In connection) To change settings of the Dial-In connection (531L/531LT-GR only) [Application] tab. . . . . . . . . . . . . . . . . To change a description of an application to run [Logon] tab . . . . . . . . . . . . . . . . . . . . . . . . . To set/cancel Automatic Logon [Windows] tab . . . . . . . . . . . . . . . . . . . . To set the colors of the WTS screen [Options] tab . . . . . . . . . . . . . . . . . . . . . . To set/cancel the printer after connecting the WTS, compression of data, the speed at which the keyboard and mouse perform on the screen, and encryption level setting. [Title] tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . To change the connection name [Firewall Settings] tab . . . . . . . . . To change the settings on the Firewall and the proxy WTS If no change is made in this settings, the settings under the [Firewall settings] of "Global ICA Client Settings" will be applied (see page 78 for details). NOTE · When changing settings in the Dial-In connection, click and show the [Call Option] tab of [Device Properties] of the [Dial-In] tab before clicking [OK] to close the window. 54 4. ADDING & CHANGING A CONNETION NAME English 4-4. Setting an Autostart Connection This function configures a connection to start automatically each time the eClient is turned on. (This function is available for a LAN connection. ) 1. 5. Display the "Terminal Connection Manager" dialog box. Select the desired Connection Name for Autostart Connection. Click [Startup. . . ] "Connection Startup" dialog box is displayed. Select [Automatically start the selected connection at startup. ] Click [OK] to save the setting. The setting is effective from the next startup. 4. ADDING & CHANGING A CONNETION NAME 55 English 5. LOGON & LOGOFF This chapter shows how to log on to and log off from a WTS. 5-1. "Terminal Connection Manager" dialog box is displayed. Please follow the instruction depending on the network environment of the eClient. Modem connection (531L/531LT-GR only) * Dial-Up connection to the RAS Server Click the active button of a small window on the right bottom of the screen. A dial-up connection is made by clicking the button. Check the clock's running, and go onto step 3. * Dial-In connection to the Citrix MetaFrame Server Go to step 3. [. . . ] (8) Close the mouse trackball cover. 9. SPECIFICATIONS 530L CPU and Memory Display CPU Memory LAN LCD Panel NEC VR4121-168, 168 MHz RAM; 32 MB, ROM;16 MB 10BASE-T 38 cm (15 inch) TFT color LCD panel Anti-Glare Hard Coating (Viewing Angle: Horizontal; 120°, Vertical; 140°) 0. 297 mm x 0. 297 mm 1024 x 768 304. 1 mm (H) x 228. 1 mm (V) (11. 9" (H) x 8. 9" (V)) Dot Pitch Resolution Viewable Image Size Display Color 256 / 65536 colors Microsoft Remote Desktop (RDP) Complying Protocol Citrix Independent Computing Architecture (ICA) Software Microsoft Windows CE Version 2. 12 Windows-based Terminal 1. 5 Browser Add-on Citrix ICA Client 6. 3 Microsoft Windows NT Server 4. 0 Terminal Server Edition, Microsoft Windows 2000 Server / Advanced Server / DataCenter Server, Citrix MetaFrame 1. 8 / 1. 8 + FR1 / XP PS/2 2 button Mouse 100-120/200-240 VAC ± 10 %, 50/60 Hz, 0. 5/0. 3 A Min: 30 W, Power saving mode: Less than 5 W 10BASE-T (RJ-45) x 1 PS/2 (Mini DIN 6 pin) x 2 IEEE1284 (D-Sub 25 pin) x 1 396 mm (W) x 390 mm (H) x 164 mm (D) (15. 6" (W) x 15. 4" (H) x 6. 5" (D)) 5. 0 kg (11. 0 lbs. ) (without the tilt stand 3. 6 kg (7. 9 lbs. )) Complying Software for Windows Terminal Server Mouse Power Supply Power Consumption Interface LAN Connector Keyboard, Mouse Parallel Dimensions (With the tilt stand) Weight Environmental Specifications Temperature Humidity Certifications and Standards 100 -120 VAC range Operating: 0°C to 35°C (32°F to 95°F) Storage: -20°C to 60°C (-4°F to 140°F) 30 % to 80 % R. H. Non-condensing TÜV/NRTL, c-TÜV, FCC class A, CB, TÜV Rheinland Ergonomics Approved, EPA ENERGY STAR® program, TCO'99 CE, CB, TÜV Rheinland/GS, TÜV Rheinland/Ergonomic Approved, EPA ENERGY STAR® program, TCO'99 200-240 VAC range 96 10. SPECIFICATIONS English 531L CPU and Memory Display CPU Memory LAN LCD Panel NEC VR4121-168, 168 MHz RAM; 32 MB, ROM;16 MB 10BASE-T 38 cm (15 inch) TFT color LCD panel Anti-Glare Hard Coating (Viewing Angle: Horizontal; 120°, Vertical; 140°) 0. 297 mm x 0. 297 mm 1024 x 768 (768 x 1024) 304. 1 mm (H) x 228. 1 mm (V) (11. 9" (H) x 8. 9" (V)) Dot Pitch Resolution Viewable Image Size Display Color 256 / 65536 colors Microsoft Remote Desktop (RDP) Complying Protocol Citrix Independent Computing Architecture (ICA) Software Microsoft Windows CE Version 2. 12 Windows-based Terminal 1. 5 Browser Add-on Citrix ICA Client 6. 3 Microsoft Windows NT Server 4. 0 Terminal Server Edition, Microsoft Windows 2000 Server / Advanced Server / DataCenter Server, Citrix MetaFrame 1. 8 / 1. 8 + FR1 / XP PS/2 2 button Mouse 100-120/200-240 VAC ± 10 %, 50/60 Hz, 0. 5/0. 3 A Min: 30 W, Power saving mode: Less than 5 W 10BASE-T (RJ-45) x 1 PS/2 (Mini DIN 6 pin) x 2 IEEE1284 (D-Sub 25 pin) x 1 RS-232C (D-Sub 9 pin) x 1 396 mm (W) x 390 mm (H) x 164 mm (D) (15. 6" (W) x 15. 4" (H) x 6. 5" (D)) 5. 0 kg (11. 0 lbs. ) (without the tilt stand 3. 6 kg (7. 9 lbs. )) Complying Software for Windows Terminal Server Mouse Power Supply Power Consumption Interface LAN Connector Keyboard, Mouse Parallel Serial Port Dimensions (With the tilt stand) Weight Environmental Specifications Temperature Humidity Certifications and Standards 100 -120 VAC range Operating: 0°C to 35°C (32°F to 95°F) Storage: -20°C to 60°C (-4°F to 140°F) 30 % to 80 % R. H. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EIZO ECLIENT 531LT-GR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EIZO ECLIENT 531LT-GR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag