User manual ELECTRO-VOICE 603T DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTRO-VOICE 603T. We hope that this ELECTRO-VOICE 603T user guide will be useful to you.

Lastmanuals help download the user guide ELECTRO-VOICE 603T.


ELECTRO-VOICE 603T DATASHEET: Download the complete user guide (500 Ko)

You may also download the following manuals related to this product:

   ELECTRO-VOICE 603T DATASHEET 2 (704 ko)

Manual abstract: user guide ELECTRO-VOICE 603TDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains. Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage. The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times. [. . . ] Programming an automatic reaction, when specific thresholds are being exceeded or fallen below, is also possible. With an 603T installed, the integrated impedance testing function allows very precise monitoring of the connected loudspeaker systems. the impedance testing function utilizes the internal test tone signal generator and voltage/ current measuring to determine the impedance of the loudspeaker systems including crossovers and cables over the entire frequency range. IRIS-NetTM plots an impedance curve of the measured impedance that can be compared with a formerly stored reference curve at any time. this reveals even smallest loudspeaker defects or deficiencies instantly. Beyond that, linear-phase FIR-filters, zero-latency FIR-filters and digital speaker protection algorithms are available to optimize the amplifiers and loudspeaker system. Control outputs (GPO's) allow the connection of external components, which, for example, are used to signal specific states to peripheral equipment. Consequently, an amplifier with a 603T module installed corresponds to highest safety requirements. the 603T has been designed with uncompromising audio quality in mind. Analog audio inputs (internally) and an AES3 (AES/EBU) digital audio input with XLR-type connector are provided. Using the analog audio input offers a dynamic range of 120 dB, which, by the way, is an absolute peak value for digital audio devices. The following table illustrates the relation between data rate and bus length or network size. The LED blinks rhythmically every 3 seconds, when the module's address is set to "00", which means that it is disconnected from the CAN bus and software control. The LED blinks rhythmically in intervals of one second, when an address in the range of 01 to 250 has been assigned to the module and there has not yet been any activity on the CAN bus. As soon as communication on the CAN bus is recognized, the LED lights for at least 100 ms, when the power amplifier sends data on the CAN bus. The two address selector switches are for setting the network address of the 603T. The LOW selector switch sets the lower digit, while HIGH sets the higher digit. Address 0 (00 hex, delivery status) disables remote communication between the 603T and the bus. The module does not appear in the system, even though it is physically connected to the CAN-bus. The CONTROL PORT of the 603T provides two control inputs, two control outputs and reference connections for +5V and ground. They can be used for example for switching between power on / standby modes, switching between presets or to control parameters. The two control contacts IN1 and IN2 are internally connected via pull-up resistors and carry +5V (open). [. . . ] In general, it does not matter if the bus member is a 603T, a USBCAN converter or another device. The CAN bus has to be terminated with a 120 terminating resistor at both ends. If the termination is missing or an improper resistor value is used, network errors can occur as a signal is reflected on the bus at both bus ends. Because of the superposition of the reflection with the original signal, the original signal is blurred. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE 603T

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE 603T will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag