User manual ELECTRO-VOICE 967 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTRO-VOICE 967. We hope that this ELECTRO-VOICE 967 user guide will be useful to you.

Lastmanuals help download the user guide ELECTRO-VOICE 967.


ELECTRO-VOICE 967 DATASHEET: Download the complete user guide (635 Ko)

Manual abstract: user guide ELECTRO-VOICE 967DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] power: 2 x 120°-150°, *2 x 150° 20-30 meters, *20-25 meters 3, 000 Watts cont. * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left In 2 Out 1 Main Right Lo L Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #37 (1152/64), #39(1152/94) Comments Options For medium SPL's as stand alone. In higher SPL applications as supplement. P2000 may be used through out (deduct ~3 dB on HF input level). P3000 may be used through out (deduct ~6 dB on HF input level). System Applications Xi Series 1. 3 2-Way Stereo Theatre, Industrial Presentations, Delay Line, Side-Fill XI 1123 XI 1123 Left Right L: 2 " + 10" R: 2 " + 10" L: 12 " R: 12 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 2 x Xi 1123/106 2 x P 1200 2 x NL8 long 1 Horizontal coverage: Average distance: Total amp. [. . . ] power: 2 x 100° 25-30 meters 1, 000 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left In 2 Out 1 Main Right Lo L Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #47 Comments Options Preset #47 is overlapped mode for maximum vertical directivity. SPL use 250 Hz X-Over setting. MF and HF horns could be rotated for vertical use. System Applications Xi Series 2. 1 2-Way Stereo+Sub Disco, Club, Theatre XI 1122 XI 1122 XI 1122 XI 1122 Sub Left Right Spare 2 x 18 " L: 2 " R: 2 " 2 x 18 " L: 12 " R: 12 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1122, 2 x Xi 2181 1 x P 1200, 1 xP 2000, 1x P 3000 4 x NL4, 2 x NL8 2 Horizontal coverage: Average distance: Total amp. power: 2 x 120°-150°, 4 X 80° 15-20 meters 4, 300 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 #1 Main Left #2 Sub Comments In 2 Out 1 Main Right Lo L Sub Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #35 (HP on 1&3 to 80Hz) #42 (adjust Level on Out1) Options For dance floor applications use 1 Xi 1122 per corner. If no separate subfeed is available use sum L+R. P3000 may be used through out alternatively. 3rd Xi 2181 may be added. System Applications Xi Series 2. 2 2-Way Stereo+Sub Disco, Theatre, Club, Band XI 1152 XI 1152 XI 1152 XI 1152 Sub Spare Left Right 2 x 18 " L: 2 " R: 2 " 2 x 18 " L: 15 " R: 15 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1152 (64 or 94), 2 x Xi 2181 1 x P 1200, 1 x P 3000 2 Horizontal coverage: Average distance: Total amp. power: 2 x 100°-120°, 4 x 60°, *4 x 90° 15-20 meters 5, 400 Watts (cont. ) Dx 38 configuration * OS V1. 05, might change w/o prior notice Dx38 In 1 #1 Main Left #2 Sub Comments In 2 Out 1 Main Right Lo L Sub Out 2 Hi L Out 3 Lo R Out 4 Hi R Preset * #37 (1152/64), #39 (1152/94)1 #42 (adjust Level on Out1) Options 1 Data for Xi 1152/64, for Xi 1152/94. 3rd Xi 2181 may be added. System Applications Xi Series 2. 3 2-Way Stereo+Sub Dance Floor (250 m 2) Xi 1123 Xi 1123 Xi 1123 Xi 1123 Sub Left Right S: 2 x 18 " S:2 x 18 " L: 12 " L:10 " + 2 " S: 2 x 18 " S:2 x 18 " L: 12 " L:10 " + 2 " S: 2 x 18 " S:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1123, 6 x Xi 2181 2 x P 2000, 3 x P3000 2 Horizontal coverage: Average distance: Total amp. SPL use 250 Hz X-Over setting. Xi 2123 could be rotated by 90° if height ist limited. (Xi 2123 triamp mode ­ needs additional P1200). System Applications Xi Series 3. 5 3-Way Stereo Large Hall Main PA System Xi 2183 Xi 2183 Left Right L: 2 " R:2 " L: 12 " R:12 " L: 2 x 18 " R:2 x 18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 2 x Xi 2183 1 x P1200, 1 x P2000, 1 x P3000 2 Horizontal coverage: Average distance: Total amp. power: 2 x 60° 35 meters 3, 500 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left #2 Main Right Comments Out 1 Lo L Lo R Out 2 Mid L Mid R Out 3 Hi L Hi R Options Out 4 Preset * #41 #41 For more low end Xi 1191 may be added. System Applications Xi Series 4. 1 3-Way Stereo+Sub Small to medium Venue, wide · Concert Sound Connect to OP Left Sub L: 12 " L:2 " Right Spare L: 18 " L:18 " R: 12 " R:2 " S: 18 " S:18 " R: 18 " R:18 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 4 x Xi 1183, 2 x Xi 2181, 4 x Xi 1191 5 x P 3000 3 x NL8 long, 7 x NL8 short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 120°-130° 30 - 35 meters 10. 200 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 In 1 In 2 #1 Main Left Sub #2 Main Right Comments Out 1 Sub Out 2 Lo L Lo R Out 3 Mid L Mid R Out 4 Preset * Hi L #50 (Out1, route to In2), #42 (Out2: HP from 80Hz to 50Hz) Hi R #42 (Out2: HP from 80Hz to 50Hz) Options System Applications Xi Series 4. 2 3-Way LCR+Sub Medium Venue, wide · Musical/Theatre L C R 4 x Xi 1082 Left Center Sub L: 2" C:2" Right Fill L: 10" C:10" Fill: Xi 1082 R: 2 " L: 2 x 12" C:2 x 12" Sub: 2 x 18" Sub:2 x 18" R: 2 x 12" R: 1 x 10 " Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 3 x Xi 2123, 4 x Xi 1191, 4x Xi 1082 2 x P 1200, 3 x P2000, 1 x P3000 5 x NL8 long, 6 x NL8 short 3 Horizontal coverage: Average distance: Total amp. power: 3 x 100° 20 - 25 meters 6, 300 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 #1 #2 #3 In 1 In 2 Main Left Sub Center Right Fill Out 1 Lo L Lo C Lo R Out 2 Mid L Mid C Mid R Out 3 Hi L Hi C Hi R Out 4 Sub Fill Options Preset * #50 (route Out4 to In2) #50 #50 (route Out4 to In2, clear Out4 filters) MF and HF horns could be rotated for vertical use. 2 Xi 2181 could be used alternatively. Comments System Applications Xi Series 5. 1 4-Way Stereo Medium to Large Venue · Concert Sound Left Spare Right L: 12" L:2" R: 12" R:2" L: 18" (1183) L:18" (1183) R: 18" (1183) R:2" (1183) L: 2 x 18" (2181) L: 2 x 18" (2181) R: 2 x 18" (2181) R:2 x 18" (2181) Equipment Capacity Cabinets: Amps: Cabeling: Dx38: 8 x Xi 1183, 4 x Xi 2181 6 x P 3000 4 x NL8 long, 8 x NL8 short 2 Horizontal coverage: Average distance: Total amp. power: 2 x 120°-130° 30 - 40 meters 17, 000 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 #1 #2 #3 In 1 In 2 Main Left Main Right Sub Mono Out 1 Sub L Sub R Sub M Out 2 Lo L Lo R Out 3 Mid L Mid R Options Out 4 Hi L Hi R Preset * #42 #42 #36 Comments System Applications Xi Series 7. 1 4-Way Stereo+Sub+Center+Delay Large Venue · Concert incl. [. . . ] power: 2 x 120°-130° 30 - 40 meters 17, 000 Watts * OS V1. 05, might change w/o prior notice Dx 38 configuration Dx38 #1 #2 #3 In 1 In 2 Main Left Main Right Sub Mono Out 1 Sub L Sub R Sub M Out 2 Lo L Lo R Out 3 Mid L Mid R Options Out 4 Hi L Hi R Preset * #42 #42 #36 Comments System Applications Xi Series 7. 1 4-Way Stereo+Sub+Center+Delay Large Venue · Concert incl. Fills (4 Way) Center cluster (2 Way) (4 Way) Delay/Frontfill (2 Way) Delay/Frontfill (2 Way) Left Sub Center Delay L Delay R Right L: 12 " L: 2 " S: 18 " S:18 " DL: 2 x 12 " DL:10" +2 " R: 12 " R:2 " L: 18 " (1183) L:18 "(1183) C: 2 x 12 " C: 10 " +2 " DR: 2 x 12 " DR:10" +2 " R: 18 " (1183) R: 18 " (1183) L: 18 " (2181) L: 18 " (2181) R: 18 " (2181) R: 18 " (2181) Equipment Capacity Cabinets: Amps: Cabeling: Dx38: Dx38 #1 #2 #3 #4 8 x Xi 1183, 4 x Xi 2181, 6 x Xi 1191 3 x Xi 2123 10 x P 3000 4 Horizontal coverage: Average distance: Total amp. power: 2 x 120°-130°, 3 x 100° 60 meters 21, 000 Watts Dx 38 configuration * OS V1. 05, might change w/o prior notice In 1 In 2 Main Left Sub Mono Center Delay L Delay R Main Right Out 1 Sub L Sub M Sub R Out 2 Lo L Out 3 Mid L Lo C Mid R Options Out 4 Hi L Hi C Hi R Lo R Preset * #42 #49 (Out 3&4), #36 (Out1) #49 #42 Comments Preset #49 is overlapped mode for maximum vertical directivity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE 967

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE 967 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag