User manual ELECTRO-VOICE CPS4.10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTRO-VOICE CPS4.10. We hope that this ELECTRO-VOICE CPS4.10 user guide will be useful to you.

Lastmanuals help download the user guide ELECTRO-VOICE CPS4.10.


ELECTRO-VOICE CPS4.10 : Download the complete user guide (4069 Ko)

Manual abstract: user guide ELECTRO-VOICE CPS4.10

Detailed instructions for use are in the User's Guide.

[. . . ] The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated , , dangerous voltage" within the product's enclosure that may be of sufficent magnitude to constitute a risk of electric shock to persons. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarized or the grounding-type plug. I the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. [. . . ] Without sufficient cooling/ventilation, the power amplifier may automatically enter protect mode. Do not use the power amplifier near heat sources, like heater blowers, stoves or any other heat radiating devices. To ensure trouble-free operation, make certain that the maximum allowable ambient temperature of +40°C is not exceeded. For fixed amplifier installations in a device control room that incorporates a central air-cooling system or air conditioners, calculating the maximum heat emission may be necessary. They are not running permanently but the running speed of the fans is controlled continuously depending on the ambient temperature. The temperatures of the power amp`s channels are registered and monitored separately. The MODE switch on the power amp`s rear panel defines how the audio inputs handle the input signals. In the following description of the modes DUAL, PARALLEL or BRIDGED the generic letters A and B are used for the two audio inputs of a MODE switch (e. DUAL In DUAL mode, the two channels of the power amplifier work independent from each other. This mode should be used if a high number of speaker with medium or low power rating should be driven in low impedance mode (LZ). In 4 Ohm mode the power amplifier reaches maximum output power having a load of 4 connected. Up to 2 cabinetts having a impedance of 8 each can be driven by each amplifier channel. The 70 V mode allows connection of 70 V loudspeaker lines (Direct Drive) in high impedance mode (HZ) without using output transformers. In this case the maximum number of loudspeakers connected to an output channel is only limited by the amplifier`s output power (500 W for CPS4. This mode should be used if the distance between amplifier and speaker is larger than 50 metres (approx. The 100 V mode allows connection of 100 V loudspeaker lines (Direct Drive) in high impedance mode (HZ) without using output transformers. In this case the maximum number of loudspeakers connected to an output channel is only limited by the amplifier`s output power (500 W for CPS4. This mode should be used if the distance between amplifier and speaker is larger than 50 metres (approx. 3 shows all possible combinations of output power and connected load for power amps operated in low-impedance mode. 5 it is possible to freely select the output power in a range between 100 watts to 500 watts for loads ranging from 2 ohms to 10 ohms per channel. 10 it is possible to freely select the output power in a range between 100 watts to 1000 watts for loads ranging from 2 ohms to 10 ohms per channel. additionally , the Remote Control Module RCM-810 allows switching a 50 Hz High-Pass filter on per channel. [. . . ] The LOW selector switch sets the lower digit, while HIGH sets the higher digit. Address 0 (00 hex, delivery status) disables remote communication between the RCM-810 and the bus. The module does not appear in the system, even though it is physically connected to the CAN-bus. 3 STATUS LED The STATUS LED is for monitoring the communication on the CAN bus. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE CPS4.10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE CPS4.10 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag