User manual ELECTRO-VOICE E-V 11 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELECTRO-VOICE E-V 11. We hope that this ELECTRO-VOICE E-V 11 user guide will be useful to you.

Lastmanuals help download the user guide ELECTRO-VOICE E-V 11.


ELECTRO-VOICE E-V 11 DATASHEET: Download the complete user guide (358 Ko)

Manual abstract: user guide ELECTRO-VOICE E-V 11DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 100-240VAC 50/60Hz Features The E-V 11 is equipped with TNC type connectors. Low loss coaxial cables are also supplied for splitter to receiver antenna jack connections. Power out jacks and cables are provided to supply up to four receivers thus eliminating excess power supply clutter. [. . . ] Rack panel mounting "ears" allow the E-V 11 to be mounted in a standard 19 inch equipment rack. "Knock outs" in the ears allow front connection of antenna cables. -1- System Configuration Figure 2 illustrates the typical system configuration using the E-V 11. Figure 3 illustrates an arrangement where two splitters have been cascaded. By connecting one of the outputs of the first splitter to the antenna inputs of the second splitter, three additional receivers may be driven by a single pair of antennas. SPECIAL NOTE: In any system, unused splitter outputs should be terminated with a 50 ohm "dummy load". See the accessories listing at the end of this manual APD4 + POWER Antenna/Power Distribution System R Front View 90-260 VAC 50-60 Hz OUTPUT A INPUT A 1 2 3 4 1 POWER OUT 2 3 4 OUTPUT B 1 2 3 4 INPUT B 15 VDC POWER Rear View Figure 1 Front and Rear View -2- 90-260 VAC 50-60 Hz OUTPUT A INPUT A 1 2 3 4 1 POWER OUT 2 3 4 OUTPUT B 1 2 3 4 INPUT B 15 VDC POWER RECEIVER 1 RECEIVER 2 RECEIVER 3 RECEIVER 4 Figure 2 System Configuration ANTENNA ANTENNA 90-260 VAC 50-60 Hz OUTPUT A INPUT A 1 2 3 4 1 POWER OUT 2 3 4 OUTPUT B 1 2 3 4 INPUT B 15 VDC POWER TO RECEIVERS ONLY TO RECEIVERS OR SPLITTERS 90-260 VAC 50-60 Hz OUTPUT A INPUT A 1 2 3 4 1 POWER OUT 3 2 OUTPUT B 4 1 2 3 4 INPUT B 15 VDC POWER TO RECEIVERS ONLY (DO NOT FEED SPLITTERS FROM SECONDARY UNITS) Figure 3 Cascading -3- Antenna Requirements The E-V 11 may be used with a variety of antennas. For best results, use a pair of LPA-500 directional log periodic antennas. The LPA-500 offers the best performance and broadest bandwidth available. This power is disabled when the UAD4 leaves the factory but may be turned on by the installer. To turn on the 12 volts, first take off the cover of the split ter by re mov ing the screws. To turn on power, un plug the jumper and install it on both pins of the header. CAUTION: Do not attach antennas and splitters with a DC short circuit to the antenna in jacks when the power is turned on. The following antennas and accessories may be used with power on: FA-1, CLA-X, LPA-500B, and UAA-500. The following antennas and accessories may be used with the power off: FA-1, CLA-X, and LPA-500. J16 POWER ON J16 POWER OFF J11 POWER ON J11 POWER OFF Figure 7 Moving Jumper (Be sure to move jumper on both headers) -6- E-V 11 Accessories and Replacement Parts AC Power Cables 550024000 550024002 550024013 690513 Europe U. K. North America Japan R LPA-500 THIS END TOWARD TRANSMITTER TP-2 50 OHM/TNC dummy load (For unused outputs on the UAD-2) Part No. 691459 690396 690401 LPA-500 450-900 MHz Log Periodic Antenna Includes mounting hardware and 10 feet (3 meter) coaxial cable with TNC connectors Order No. [. . . ] North America Japan R LPA-500 THIS END TOWARD TRANSMITTER TP-2 50 OHM/TNC dummy load (For unused outputs on the UAD-2) Part No. 691459 690396 690401 LPA-500 450-900 MHz Log Periodic Antenna Includes mounting hardware and 10 feet (3 meter) coaxial cable with TNC connectors Order No. LPA-500 Special low loss antenna cables with TNC connectors Model CXU-10 CXU-25 CXU-50 CXU-75 CXU-100 Length 10 Ft. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELECTRO-VOICE E-V 11

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ELECTRO-VOICE E-V 11 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag