User manual ELK PRODUCTS ELK-BLT V.1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ELK PRODUCTS ELK-BLT V.1. We hope that this ELK PRODUCTS ELK-BLT V.1 user guide will be useful to you.

Lastmanuals help download the user guide ELK PRODUCTS ELK-BLT V.1.


Mode d'emploi ELK PRODUCTS ELK-BLT V.1
Download
Manual abstract: user guide ELK PRODUCTS ELK-BLT V.1

Detailed instructions for use are in the User's Guide.

[. . . ] In some cases a battery will recover and pass a test after being recharged. However, a second test should be performed a few days after recovery to accurately assess the overall life of the battery. The average life cycle of a sealed lead-acid battery in standby use on a float charge is 3 to 5 years. A battery with a Mhos reading of less than 70% of its Charged, Full Capacity value is no longer considered serviceable and should be replaced. Additional Information Adding to the Battery Reference Chart If the battery you are trying to test is not included in the Battery Reference Chart it may be necessary to research and generate the data on your own. [. . . ] For standby batteries, peak capacity is normally reached after about three months on a float charging system. For cyclic use batteries, full capacity may not be reached until after ten to thirty cycles, depending upon the depth of discharge and the charging method. Accumulating Trend Analysis over a Period of Years Trending of periodic conductance measurement data can yield valuable insights for estimating the remaining life of the battery. For instance, suppose that a battery has been in service for three years and that the LifeTester measurements after the 1st year was 99% of the Charged, Full Capacity reference, 96% after the 2nd year, and 93% after the 3rd year. Since the battery is still at 93% of the reference value, and is only dropping about 3% per year, it is highly likely that this battery will not need replacing before the end of the 4th year. On the other hand, suppose that the readings were 98% after the 1st year, 91% after the 2nd year, and 81% after the 3rd year. The rate of decay has increased from 2% to 7% to 10% per year. This indicates that although the battery is still serviceable, it is degrading more and more rapidly. It is unlikely that this battery will still be serviceable for another year. Under these circumstances, either the battery should be replaced early or the service interval should be shortened to catch this battery before a system failure. · For the most accurate results a battery should be allowed to charge for 24 hours prior to testing. In addition, the LifeTester should be allowed to adjust to room temperature prior to use. (828)397-4200 Voice (828)397-4415 Fax http://www. elkproducts. com email: info@elkproducts. com PO Box 100 · Hwy. 70W · Hildebran, NC 28637 · USA L504 1801 6 7 8 9 OPERATING INSTRUCTIONS ADJUSTING THE REFERENCE SETTING AUTOMATIC SHUTDOWN If the LifeTester is left connected to a battery for more than 30 seconds after the test is complete, it will automatically shutdown to conserve battery power. Disconnecting and reconnecting a test lead will restart the test procedure. 1. Disconnect the battery from its equipment. Connect the BLACK test lead to the Negative (-) terminal, and the RED to the Positive (+). The Red "Reversed Battery Leads" indicator will light if the leads are accidentally reversed. The LifeTester is reverse polarity protected. 7. Record the Ambient Temperature, which is displayed in Fahrenheit (F) or Celsius (C). CELSIUS. Consult the Battery Reference Chart on page 5 for the proper reference setting for your battery. After initial connection (power-up) and while the Mhos reference value is still being displayed press the Red ADJUST button once. To increase the reference setting press the Green (Up) button. To decrease the setting press the Red (Down) button. Holding either button will make the value jump by a value of 10. [. . . ] Record the Battery Voltage, which is displayed for the next 1. 5 seconds. If the battery voltage is below 12. 3 volts, the test will stop and the battery voltage will alternately display with [ Err ], indicating that the battery voltage is too low for the test to continue. A new battery, out of the box, will generally read around 12. 6 Volts. A fully-charged battery will read between 12. 6 Volts and 13. 5 Volts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ELK PRODUCTS ELK-BLT V.1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ELK PRODUCTS ELK-BLT V.1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag