User manual EMERSON FANS HF956

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EMERSON FANS HF956. We hope that this EMERSON FANS HF956 user guide will be useful to you.

Lastmanuals help download the user guide EMERSON FANS HF956.


Mode d'emploi EMERSON FANS HF956
Download
Manual abstract: user guide EMERSON FANS HF956

Detailed instructions for use are in the User's Guide.

[. . . ] THE FAN MUST BE MOUNTED WITH THE FAN BLADES AT LEAST 10 FEET FROM THE FLOOR TO PREVENT ACCIDENTAL CONTACT WITH THE FAN BLADES. SUITABLE FOR USE WITH SOLID-STATE SPEED CONTROLS. ALWAYS PROPERLY CONNECT THE SECONDARY SUPPORT CABLE INCLUDED WITH THIS FAN (FOLLOW "INSTALLATION" SECTION CAREFULLY). THE SUPPORT BEAM OR JOIST MUST BE SECURE AND CAPABLE OF SUPPORTING AT LEAST 50 POUNDS. Checking Contents of Package 1. [. . . ] Put the upper canopy and lower canopy on the hanger pipe assembly, facing in the proper direction. (See Figure 1. ) NOTE: The fan is supplied with a 8" and a 22" hanger pipe. If you are going to use the 8" pipe, first remove the hanger assembly from the 22" pipe and install it on the 8" pipe. Be sure that the nut is securely tightened and the hairpin clip properly installed. (4) MOTOR CONNECTOR (3) SCREWS (2) COVER PLATE 5. Slide the lower canopy down the hanger pipe and securely tighten the set-screw against the hanger pipe. (See Figure 3. ) CAUTION: Blades come in balanced sets of three. Do not mix blades if installing more than one fan. NOTE: Install the blade gaskets between the blades and the motor. Install the three blades onto the motor using spring washers, M6 x 1/2" screws and blade gaskets supplied. Securely tighten the six blade screws. (5) SWITCH CUP CONNECTOR WARNING TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE FLANGES WHEN INSTALLING THE BLADES, BALANCING THE BLADES, OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES. M6 x 1/2" SCREW (2 PER BLADE) SPRING WASHER (2 PER BLADE) (1) SWITCH Figure 1 CUP 2. Install the screw-type J-hook so that hook extends 2-1/2" below the outlet box. Lift the fan onto the J-hook and position as shown in Figure 7. Make sure the motor wires and safety cable at the top of the hanger pipe are positioned behind J-hook as illustrated in Figure 7. CAUTION: The safety cable must not be placed between the rubber roller and the hook, but rather as illustrated in Figure 7. 1. Connect the green grounding wire from the fan motor to the green grounding wire from the supply source. Securely connect wires with wire connectors supplied. (See Figure 9. ) CAUTION: Use larger U. L. listed wire connectors if supply source wires are larger than #12 AWG. BLACK SUPPLY (HOT) WHITE SUPPLY (NEUTRAL) GROUND WIRE GREEN WIRE (GROUND) FROM FAN WIRE CONNECTORS (3) WHITE FAN WIRE Figure 9 BLACK FAN WIRE CABLE CLAMPS SAFETY CABLE 2. Securely connect the fan motor white wire to the supply white (neutral) wire using a wire connector supplied (Figure 9). Securely connect the fan motor black wire to the supply black (hot) wire using wire connector supplied. After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black leads on the other side of the outlet box. WARNING CHECK TO SEE THAT ALL CONNECTIONS ARE TIGHT, INCLUDING GROUND, AND THAT NO BARE WIRE IS VISIBLE AT THE WIRE CONNECTORS, EXCEPT FOR THE GROUND. [. . . ] This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of this Owner's Manual. This warranty is valid only in the fifty states of the United States. No other written or oral warranty applies. No employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS HF956

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS HF956 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag