User manual EMERSON FANS OLYMPIA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EMERSON FANS OLYMPIA. We hope that this EMERSON FANS OLYMPIA user guide will be useful to you.

Lastmanuals help download the user guide EMERSON FANS OLYMPIA.


Mode d'emploi EMERSON FANS OLYMPIA
Download
Manual abstract: user guide EMERSON FANS OLYMPIA

Detailed instructions for use are in the User's Guide.

[. . . ] READ AND SAVE THESE INSTRUCTIONS Emerson Fans Designed by OLYMPIA Ceiling Fan Owner's Manual Model Numbers KF100AP00 Antique Pewter with Natural Cherry/Mahogany Blades KF100OZ00 Olde Bronze¨ with Teak/Olde Bronze¨ Blades Net Weight: 30. 0 Lbs. Part No. BP7280 ! WARNING This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Tools Needed for Assembly One Phillips head screwdriver One wire stripper One stepladder Six wire connectors (supplied) Safety Instructions 1. Read your owner's manual carefully and keep it for future reference. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. [. . . ] Refer to Figure 13 and 14 and connect the receiver wires to the supply wires and the fan motor wires as follows: a. Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation). Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire. Securely connect the supply black wire (hot) wire to the receiver black (AC IN L) wire. Securely connect the fan motor white wire to the receiver white (TO MOTOR N) wire. Securely connect the fan motor black wire to the receiver black (TO MOTOR L) wire. Securely connect the fan motor blue wire to the receiver blue (FOR LIGHT) wire. ! WARNING WARNING OUTLET BOX TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB The fan must be hung with at least 7' of clearance from floor to blades (Figure 10). CEILING Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock. CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver. Position the supply wires to the left side of the outlet box (Figure 13); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 13. NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire SUPPLY WHITE WIRE (NEUTRAL) AT LEAST 7' Figure 11 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 12). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 11). ! Figure 10 ! FLOOR WARNING WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. outlet box listed as "Acceptable for Fan Support". ! WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. NOTE: CEILING COVER, SUPPL WIRES AND FAN Y WIRES OMITTED FOR CLARITY. OUTLET BOX Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. [. . . ] All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR. Do To Correct Problems: Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS OLYMPIA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS OLYMPIA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag