User manual EMERSON FANS SUMMER NIGHT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EMERSON FANS SUMMER NIGHT. We hope that this EMERSON FANS SUMMER NIGHT user guide will be useful to you.

Lastmanuals help download the user guide EMERSON FANS SUMMER NIGHT.


Mode d'emploi EMERSON FANS SUMMER NIGHT
Download
Manual abstract: user guide EMERSON FANS SUMMER NIGHT

Detailed instructions for use are in the User's Guide.

[. . . ] READ AND SAVE THESE INSTRUCTIONS ® SUMMER NIGHT® 52" Damp Location Ceiling Fan Owner's Manual Net Weight: Model No. CF652WW00 CF652BQ00 CF652DB00 CF652AW00 CF652V00 CF652W00 CF652OB00 CF652WB00 14. 4 Lbs. LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for ten years from the date you purchased your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. [. . . ] Route the motor leads through the hanger ball/downrod assembly. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 1). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the 3 hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed. ! WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling. 3/16-24 x 1/2" SETSCREW CLEVIS PIN MOTOR COUPLING HAIRPIN CLIP JAMNUT 8. Rotate the motor hub until the flange screw hole is next to the cutout in the switch housing plate. Attach one blade assembly to the motor hub using two 1/420 x 1/2" Phillips oval head flange screws. (Figure 3. ) Repeat this procedure for the other four blade assemblies. HANGER BALL/ DOWNROD ASSEMBLY SWITCH HOUSING PLATE BLADE FLANGE CEILING COVER CLEVIS PIN 3/16-24 x 1/2" SCREW WITH JAM NUT MOTOR COUPLING CLEVIS PIN HAIRPIN CLIP Figure 1 4. Back off the jam nut until it rests loosely against the setscrew head (supplied). Install the setscrew in the motor coupling (Figure 1) and tighten securely while pulling up on the downrod. Using a 5/16-inch open end wrench or pliers, tighten the jam nut securely against the motor coupling. NOTE: The setscrew and jam nut must be properly installed as described above, or fan wobble could result. The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads. IMPORTANT: THE SIDE OF THE FAN BLADE HAVING THE RIB LINE MUST BE FACING UPWARDS AS SHOWN IN FIGURE 2. Mount blade flanges to fan blades using three 3/16-24 x 5/16" slotted phillips washer head screws per blade (Figure 2). 3/16-24 x 5/16" SLOTTED PHILLIPS WASHER HEAD SCREW (3) Figure 3 MOTOR HUB 1/4-20 X 1/2" PHILLIPS OVAL HEAD FLANGE SCREWS (2) 9. The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws. [. . . ] Check line wire connections to fan and switch wire connections in switch housing. Check to make sure the screws which attach the fan blade flanges to the motor are tight. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. Tighten the setscrews securely in the motor coupling. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS SUMMER NIGHT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS SUMMER NIGHT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag