User manual EMERSON FANS WINDJAMMER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EMERSON FANS WINDJAMMER. We hope that this EMERSON FANS WINDJAMMER user guide will be useful to you.

Lastmanuals help download the user guide EMERSON FANS WINDJAMMER.


Mode d'emploi EMERSON FANS WINDJAMMER
Download
Manual abstract: user guide EMERSON FANS WINDJAMMER

Detailed instructions for use are in the User's Guide.

[. . . ] READ AND SAVE THESE INSTRUCTIONS ® ® Emerson Ceiling Fans - MODEL CF960 - WINDJAMMERTM Ceiling Fan Owner's Manual Net Weight: Model No. 27. 6 Lbs. CF960CK 00 CF960WB 00 CF960BS 00 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. [. . . ] Pull the hanger ball up tight against the pin and downrod. Be sure to push the straight leg of the securely tighten the setscrew in the hanger ball. hairpin clip through the hole near the end of the A loose setscrew could create fan wobble. clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. be properly installed to prevent the clevis pin from working loose. Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 7). ! WARNING WARNING Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall. ! To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician. WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. ! WARNING ! WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 6). CEILING To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY. OUTLET BOX AT LEAST 7' Figure 6 ! FLOOR HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBLY WARNING Figure 8 The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. 5 Wiring Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. ! WARNING THREADED STUD #8 LOCKWASHER KNURLED KNOB CEILING COVER To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation. Figure 10 ! 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation) (Figure 9). Securely connect the wires using wire connector supplied. BLACK AND BLUE FAN WIRES GROUND WIRE LISTED WIRE CONNECTOR (3) WHITE SUPPLY (NEUTRAL) NOTE: CEILING COVER OMITTED FOR CLARITY. WARNING To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. Final Assembly of the Ceiling Fan 1. Mount the blade flange to the blade using three 3/16-24 x 5/16" slotted Phillips head screws and three M5 flat washers (supplied) (Figure 11). Repeat this procedure for the remaining five blades. GREEN WIRE (GROUND) FROM HANGER BRACKET GREEN WIRE (GROUND) FROM HANGER BALL WHITE FAN WIRE BLACK SUPPLY (HOT) THREADED STUD (2) 3/16-24 x 5/16" SLOTTED PHILLIPS HEAD SCREW (3) M5 FLAT WASHER (3) BLADE Figure 9 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 9). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 9). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box. ! BLADE FLANGE Figure 11 WARNING Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. 2. Install one blade assembly to the motor hub using two 1/4-20 x 1/2" Phillips oval head screws (Figure 12). Repeat this procedure for the remaining five blade assemblies. 3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 9). Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 10). [. . . ] It could damage the motor or the blades and create the possibility of an electrical shock. WARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage. ! WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. Trouble Shooting TROUBLE 1. Loose power line connections to the fan. Check main and branch circuit fuses or circuit breakers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EMERSON FANS WINDJAMMER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EMERSON FANS WINDJAMMER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag