User manual EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1). We hope that this EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1) user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1).


Mode d'emploi EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1)
Download
Manual abstract: user guide EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1)

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual lpha CON 200 1/8 DIN Conductivity Controller with Temperature display and Transmitter Technology Made Easy . . . 68X276103 rev 1 09/2003 PREFACE This manual serves to explain the use of the lpha CON 200 controller/transmitter. This manual functions in two ways: first, as a stepby-step guide to help you operate the meter; second, it serves as a handy reference guide. This manual is written to cover as many anticipated applications of the lpha CON 200 controller/transmitter as possible. If there are doubts in the use of the lpha CON 200 controller/transmitter, do not hesitate to contact the nearest Eutech Instruments Authorized Distributor. [. . . ] Key in password "022" as per procedure in Section 5. The screen will scroll P1. 3, HYS1, and current hysteresis value. Press or keys to adjust hysteresis value. Press and keys together to return to P1. 0. Press and keys together again, to return to Conductivity measurement mode. 16 8. 4 Set Point 2 ­ P2. 0 Setup program P2. 0 allows you to set parameters for relay 2. P2. 1: select relay 2 set point value P2. 2: select relay 2 as low or high set point P2. 3: set relay 2 hysteresis value (dead band) P2 . 0 S2 P P . 1 2 S2 P 00 18 P . 2 2 P23 . S2 P H St Y LOW 100 HI H G Press and keys together (ESCAPE) at anytime, to leave Setup mode and return to Measurement mode. P2. 1: Select relay set point value Set the Conductivity value that will activate Relay 2. If measured value overshoots or undershoots Set Point value, Relay 2 will be activated and corresponding LED on front panel will light. Key in password "022" as per procedure in Section 5. Press key until screen displays P2. 0 and SP2. The screen will scroll P2. 1, SP2, then current set point value. Press or keys and adjust second relay set point. Default value is 90% of full scale of range selected. Press ENTER to confirm and continue to step three of P2. 2, or press and keys together to return to P2. 0. Press and keys together to return to Conductivity measurement mode. P2. 2: Set relay as high or low set point Select low set point to activate Relay when measured value undershoots Set point; select high set point to activate Relay when measured value overshoots Set point. Using both SP1 and SP2, you can select lo/lo, lo/hi, hi/lo or hi/hi set points. Key in password "022" as per procedure in Section 5. Press key until screen displays P2. 0 and SP2. The screen will scroll P2. 2, SP2, and LOW (or HIGH). Press the or keys to toggle between LOW and HIGH. Press ENTER to confirm and continue to step 3 of P2. 3, or press and keys together to return to P2. 0. [. . . ] Instead, it continues to be active till the value reaches the amount set by the Hysteresis band. Appendix 2: Factory Defaults Resetting the controller to factory default settings (See program P7. 0) clears all calibration data and most other setup functions. The following settings will remain unchanged: 1. Temperature compensation mode (ATC or MTC) 3. Temperature offset calibration value, if in ATC mode. Conductivity Defaults Conductivity range Set point 1 Set point 2 Temperature Defaults Temp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA CON 200 CONDUCTIVITY CONTROLLERTRANSMITTER (REVISION 1) will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag