User manual EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER. We hope that this EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER.


Mode d'emploi EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER
Download
Manual abstract: user guide EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual lpha CON 2000 Conductivity/ Total Dissolved Solids Controller / Transmitter Technology Made Easy . . . 68X216843 Rev 1 01/04 Preface This manual serves to explain the use of the lpha CON 2000 Series. The manual functions in two ways, firstly as a step by step guide to help the user operate the instrument, and secondly as a handy reference guide. This instruction manual is written to cover as many anticipated applications of the lpha CON 2000 as possible. If you have any doubts concerning the use of the instrument, please do not hesitate to contact the nearest Eutech Instruments Authorised Distributor. [. . . ] The transmitter returns to the Measurement mode. 19 Instruction Manual lpha CON 2000 6. 2 Temperature compensation (TC) sub-function This sub-function allows you to select the correct temperature compensation for optimum operations. SETUP HOLD ENT SETUP HOLD ENT SETUP HOLD ENT SETUP HOLD 4 4 4 ATC 4 ATC °C SETUP HOLD ENT 4 1. Select the "TC" sub-function, then press the ENT key. Selecting type of temperature compensation: press the or key to select the suitable type of temperature compensation: - PUR TC = Pure water temperature compensation Use pure water temperature compensation for applications in the pure water or ultrapure water industries. Note: "PUR TC" should be selected while working with pure water, usually in the 02 µS range. - LIN TC= Linear temperature compensation Use linear temperature compensation for all other applications. Press the ENT key to confirm your selection. - ­ If linear temperature compensation was selected (LIN TC): 3. Selecting the temperature compensation value for process liquid: press the or key to adjust the temperature compensation value (setting range: 0 to 10 %, factory setting: 2. 10 %). Press the ENTER key to confirm the temperature compensation value. Selecting the temperature compensation value for calibration liquid: press the or key to adjust the temperature compensation value (setting range: 0 to 10 %, factory setting: 2. 10 %). Press the ENT key to confirm the temperature compensation value. Continue with additional Setup procedures, or return to the Measurement mode by pressing the and key (escape) simultaneously. 20 Instruction Manual lpha CON 2000 6. 3 Setting temperature (Set °C°F) sub-function SETUP HO LD ENT SETUP HO LD ENT SETUP HO LD ENT SETUP HO LD ENT SETUP HO LD ENT °C 4 4 4 4 ATC 4 ATC SETUP HO LD °F SETUP HO LD ENT SETUP HO LD ENT °C 4 4 4 ATC 1. Select the "SET °C°F" sub-function, then press the ENT key. Selecting temperature unit: press the or key to select the desired temperature unit "°C" or "°F". Press the ENTER key to confirm your selection. Enable/disable ATC mode: press the or key to enable (ATC ON) or disable (ATC OFF) automatic temperature compensation. Press the ENT key to confirm your selection. - ATC disabled (ATC OFF): For manual temperature compensation you can set the process and calibration temperatures. This allows calibration at a temperature other than the process temperature. Example: setting a calibration temperature of 25°C lets you calibrate using standard solutions at 25°C, even if your process temperature is different from 25°C. Setting the process temperature: press the or key to adjust the process temperature (upper value, setting range: ­10. 0 to 125. 0°C / 14. 0 to 257. 0 °F). Press the ENT key to confirm process temperature. [. . . ] Eutech Instruments will not be responsible for any damage resulting from careless or insufficient packing. Warning: Shipping damage as a result of inadequate packaging is the user's/distributor's responsibility, whoever applicable. Please follow the guidelines below before shipment. 10. 4 Guidelines for returning unit for repair Use the original packaging material if possible when shipping the unit for repair. Otherwise wrap it with bubble pack and use a corrugated box for better protection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA CON 2000 CONDUCTIVITY CONTROLLERTRANSMITTER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag