User manual EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER. We hope that this EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER.


Mode d'emploi EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER
Download
Manual abstract: user guide EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER

Detailed instructions for use are in the User's Guide.

[. . . ] Alpha COND 560 Controller mS / µS / ºC / ºF ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. patent 6, 793, 787. AQUAfast, Cahn, ionplus, KNIpHE, No Cal, ORION, perpHect, PerpHecT, PerpHecTion, pHISA, pHuture, Pure Water, Sage, Sensing the Future, SensorLink, ROSS, ROSS Ultra, Sure-Flow, Titrator PLUS and TURBO2 are registered trademarks of Thermo Fisher. 1-888-pHAX-ION, A+, All in One, Aplus, AQUAsnap, AssuredAccuracy, AUTOBAR, AUTO-CAL, AUTO DISPENSER, Auto-ID, AUTO-LOG, AUTO-READ, AUTOSTIR, Auto-Test, BOD AutoEZ, Cable-Free, CERTI-CAL, CISA, DataCOLLECT, DataPLUS, digital LogR, DirectCal, DuraProbe, Environmental Product Authority, Extra Easy/Extra Value, FAST QC, GAP, GLPcal, GLPcheck, GLPdoc, ISEasy, KAP, LabConnect, LogR, Low Maintenance Triode, Minimum Stir Requirement, MSR, NISS, One-Touch, One-Touch Calibration, One-Touch Measurement, Optimum Results, Orion Star, Pentrode, pHuture MMS, pHuture Pentrode, pHuture Quatrode, pHuture Triode, Quatrode, QuiKcheK, rf link, ROSS Resolution, SAOB, SMART AVERAGING, Smart CheK, SMART STABILITY, Stacked, Star Navigator 21, Stat Face, The Enhanced Lab, ThermaSense, Triode, TRIUMpH, Unbreakable pH, Universal Access are trademarks of Thermo Fisher. Guaranteed Success and The Technical Edge are service marks of Thermo Fisher. PerpHecT meters are protected by U. S. PerpHecT ROSS electrodes are protected by U. S. ORION Series A meters and 900A printer are protected by U. S. [. . . ] Press or key to select the desired value. Select temperature coefficient for calibration liquid: The lower display shows `C. tC'. The upper display shows last configured temperature coefficient for calibration liquid (if any). Press or key to select the desired value. The controller reverts to tC screen. Press or key to access other setup screens or press and key simultaneously (escape) to return to measurement mode. 5. 3 Temperature Settings Automatic Temperature Compensation (ATC): The conductivity value of a sample is affected by temperature. Use ATC feature of the controller to compensate for conductivity changes when the temperature of the sample or process liquid fluctuates. Connect a separate temperature probe (Pt100/pt1000) to the controller if an integrated conductivity/Temperature probe is not available. Manual Temperature Compensation (MTC): Set the controller to MTC (disable ATC) when the temperature of sample or process liquid is constant and a temperature probe is not available. If you disable ATC, the controller allows you to set your process temperature (P. ºC) and calibration temperature (C. ºC). This allows calibration at a different temperature other than the process temperature. Example: Setting calibration temperature of 25°C lets you calibrate using standard solutions at 25°C, even if your process temperature is different from 25°C. 4 SETUP SETUP 1 SETUP HOLD 2 ENT SETUP HOLD °C 3 SETUP 5 ENT HOLD ENT HOLD °C ENT HOLD °C ATC °C ATC 2 SETUP HOLD °F 3 SETUP HOLD 6 ENT SETUP HOLD 7 SETUP ENT HOLD ENT ENT °C 1 From measurement mode press ENT key to enter setup mode as described in section 5. 1. The LCD shows the first screen of setup mode (rAng). Press or key to select Temperature settings screen (SET ºCF). Press ENT key to access temperature settings (SET ºCF). Selecting unit of measurement for temperature: The upper display shows `Unit' and the lower display shows the last configured unit of measurement for temperature. Press or key to select the desired units for temperature (ºC or ºF). Press ENT key to confirm your selection. 2 3 Enable/disable ATC: The lower display shows `AtC' and the upper display shows the last configured ATC selection (`On' or `OFF'). Press or key to enable (ATC On) or disable (ATC OFF) automatic temperature compensation. Press ENT key to confirm your selection. If ATC enabled (ATC On): 4 Selecting temperature offset: The upper display shows the last configured temperature offset value (if any), otherwise the default is zero. The lower display shows currently measured temperature reading (including last configured offset value). LCD shows `ATC' annunciator in lower-right corner. Place a thermometer, which is known to be accurate, in your sample or process liquid. [. . . ] The warranty card must be endorsed by the Authorized Distributor at the point of sale. If repair or adjustment is necessary and has not been the result of abuse or misuse within the designated period, please return ­ freight pre-paid ­ and correction will be made without charge. Thermo Scientific/ Eutech will determine if the product problem is due to deviations or customer misuse. Out of warranty products will be repaired on a charged basis. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ALPHA COND 560 CONDUCTIVITY CONTROLLER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag