User manual EUTECH INSTRUMENTS CON 700 REV 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS CON 700. We hope that this EUTECH INSTRUMENTS CON 700 user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS CON 700.


Mode d'emploi EUTECH INSTRUMENTS CON 700
Download

You may also download the following manuals related to this product:

   EUTECH INSTRUMENTS CON 700 REV 3 (622 ko)

Manual abstract: user guide EUTECH INSTRUMENTS CON 700REV 2

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual CON 700 Conductivity/ºC/ºF Bench Meter Technology Made Easy . . . Part of Thermo Fisher Scientific 68X541702 Rev. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GETTING STARTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. 1 2. 2 2. 3 Keypad Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If you intend to calibrate with one or more standards that are not listed in TABLE 1, the CON 700 must be set for manual calibration instead. 4 The factory default is automatic conductivity calibration. See Section 6. 10 to change this setting. There is no automatic calibration value available for conductivity range 1. Range # r1 r2 r3 r4 r5 Conductivity Range 0. 00 ­ 20. 00 S 20. 1 ­ 200. 0 S 201 ­ 2000 S 2. 01 ­ 20. 00 mS 20. 1 ­ 200. 0 mS TABLE 1 Automatic Calibration Values Normalization Temperature 25 ºC None 84 S 1413 S 12. 88 mS 111. 8 mS 20 ºC None 76 S 1278 S 11. 67 mS 102. 1 mS Range # r1 r2 r3 r4 r5 TDS Range (using 0. 5 TDS factor) 0 ­ 10. 00 ppm 10. 1 ­ 100. 0 ppm 101 ­ 1000 ppm 1. 01 ­ 10. 00 ppt 10. 1 ­ 100 ppt Automatic Calibration Values none none none none none 4. 2 Single or Multi-Point Calibration Use Single-Point Calibration to apply a single calibration value across all ranges. Use Multi-Point Calibration for individual calibration in each range. This will restrict an individual calibration so that it is applied to one range only. When using multi-point calibration, perform a calibration in each range that you expect to use for best results. 5 The factory default is Single-Point Calibration. See Section 6. 11 to change this setting. 4. 3 General Calibration Tips For best results, periodic calibration with known accurate standards is recommended. A maximum of one calibration point per range can be performed. If multiple calibration points are used in the same range, the most recent one will replace the previous one. When the electrode is replaced, it is best to clear the calibration to the factory default values (see Section 6. 13). Rinse or immerse the probe before calibration and between samples with clean water (deionized water is ideal). The CON 700 has non-volatile memory which will retain all calibration values, as well as meter settings and memory values upon meter shut down or unexpected power loss. To protect from erroneous calibrations, the allowable tolerance is ±40% of the factory default value. Low conductivity standard solutions (less than 20 µS) are unstable and are very temperature dependent. As a result, reproducible calibration results are challenging in lowest measurement range #1 (0. 00 to 20. 0 µS). 4. 4 Automatic Conductivity Calibration Procedure 1) 2) 3) Press as needed to select conductivity (S or mS). Dip the electrode into the conductivity standard and press . The primary display will show the factory default value, while the secondary display will lock on the appropriate automatic standard value from TABLE 1. When the READY indicator appears, press to accept. The primary reading will flash briefly before returning to measurement mode upon successful calibration. 4) 6 4. 5 Manual Conductivity & TDS Calibration Procedure 1) 2) 3) as needed to select conductivity (S or mS) or TDS Press (ppm or ppt) calibration. Dip the electrode into the calibration standard and press Provide stirring for best results. The primary display will show the current reading, while the secondary display will be the factory default value. [. . . ] Ideally T1 and T2 should bracket your measurement temperature, and should not differ by more than 5 ºC. Calculate the temperature coefficient of your solution according to the formula shown above. Enter the calculated temperature coefficient into the meter. The calculated temperature coefficient will now be applied to all the meter readings. 14 9. REPLACEMENTS AND ACCESSORIES Part number Ordering Code Item Description Eutech Instruments CON 700 Benchtop with electrode and integral stand, 100/240 VAC Replacement electrode, k = 1. 0 Epoxy/platinum electrode, k = 0. 1 Glass/platinum electrode, k = 1. 0 Epoxy/platinum electrode, k = 10. 0 SMPS, 100/240 VAC, 9V, 6W power adapter 10 S, (20) x 20mL Sachets 84 µS, 480 mL bottle* 100 S, 480 mL bottle 447 S, 480 mL bottle 500 S, 480 mL bottle 1413 S, 480 mL bottle* 1413 S, (20) x 20mL Sachets* 2764 S, 480 mL bottle 2764 S, (20) x 20mL Sachets 5. 0 mS, 480 mL bottle 12. 88 mS, 480 mL bottle* 15 mS, (20) x 20mL Sachets 111. 8 mS, 480 mL bottle* ECCON70043S CONSEN9501D 93X546101 93X546102 60X030130 ECCON10BS ECCON84BT ECCON100BT ECCON447BS ECCON500BT ECCON1413BT ECCON1413BS ECCON2764BT ECCON2764BS ECCON5000BT ECCON1288BT ECCON15000BS ECCON1118BT Oakton Instruments 35411-00 35608-74 35608-72 35608-76 35608-78 35615-07 35653-09 00653-16 00653-47 00653-18 35653-11 00653-20 35653-12 00606-10 35653-13 - * Calibration Standard Value at 25 ºC 15 10. TROUBLESHOOTING GUIDE CAUSE Main power not switched on. AC Adapter socket not inserted properly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS CON 700

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS CON 700 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag