If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS ECOTESTR PH 2. We hope that this EUTECH INSTRUMENTS ECOTESTR PH 2 user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS ECOTESTR PH 2.


Mode d'emploi EUTECH INSTRUMENTS ECOTESTR PH 2
Download
Manual abstract: user guide EUTECH INSTRUMENTS ECOTESTR PH 2

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions EcoTestr pH 2 Waterproof Pocket Tester Conditioning Before First Use: Precipitation of the sensor electrolyte may cause white crystals to form around the cap. This is normal and does not affect the tester's performance. Fill the transparent cap of the tester with 20 mm of tap water 2. [. . . ] This tester allows up to 3-point calibration. Dip sensor in 20 mm of standard solution, stir gently and wait for the value to stabilize at or near pH 7. 00 4. Press to enter the calibration sequence. Display flashes CAL momentarily, then shows a flashing default reading 5. To confirm calibration, press and wait for the auto confirmation ( En ) 6. You have successfully completed the first calibration point 7. To obtain your second and third calibration points, proceed to the next buffer value (pH 4. 00 or pH 10. 00) and repeat step 3 - 6 8. To abort calibration, press to escape ( ESC) Maintenance: 1. Rinse sensor in tap water after each use 2. In harsh samples, take readings quickly, then rinse sensor with de-ionized water immediately to remove residues and prevent electrode contamination Useful Notes: 1. To avoid cross contamination, rinse between samples and calibration standards with de-ionized water 2. To maintain tester accuracy, use tester regularly or calibrate at regular intervals as required 3. For long-term storage, fill cap with 20 mm of storage solution (NOT de-ionized water) and replace cap*. This will keep sensor conditioned and ready for next use * The tester cap is not leak-proof. Please keep tester upright during soaking. Changing Batteries: 1. To remove batteries, lift up the front battery cover to release the front catch. [. . . ] The display shows a flashing rS (reset) 3. Press again to confirm reset ( En ) or press to escape ( ESC) reset option Warranty: This tester is supplied with a warranty against manufacturing defects for a period of ONE year from date of purchase. Accessories: Eutech Order Code ECBU4BT ECBU7BT ECBU10BT ECRE005 ECDPCBT Oakton Order Code 00654-00 00654-04 00654-08 00653-04 00653-06 Description pH 4. 01 buffer solution, 480 ml bottle pH 7. 00 buffer solution, 480 ml bottle pH 10. 01 buffer solution, 480 ml bottle Storage solution for pH sensor, 480 ml bottle Protein remover solution, 480 ml bottle [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS ECOTESTR PH 2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS ECOTESTR PH 2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag