User manual EUTECH INSTRUMENTS PH 700

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS PH 700. We hope that this EUTECH INSTRUMENTS PH 700 user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS PH 700.


Mode d'emploi EUTECH INSTRUMENTS PH 700
Download

You may also download the following manuals related to this product:

   EUTECH INSTRUMENTS PH 700 REV 3 (583 ko)

Manual abstract: user guide EUTECH INSTRUMENTS PH 700

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual pH 700 pH/mV/°C/°F Bench Meter Ion 700 pH/mV/Ion/°C/°F Bench Meter Technology Made Easy . . . Part of Thermo Fisher Scientific 68X541701 Rev. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GETTING STARTED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. 1 2. 2 2. 3 Keypad Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] When the READY indicator appears, press to accept. The primary reading will flash briefly before the secondary display begins scrolling the remaining available buffers. 3) Rinse the pH and ATC electrodes then dip into the next pH buffer. The secondary display will lock on the appropriate buffer value. The primary reading READY indicator appears, press will flash briefly then display the percent efficiency (slope) before the secondary display begins scrolling the remaining available buffers. 4 4) To calibrate another buffer repeat step 3) or press to return to the measurement mode. Note: The meter will automatically return to measurement mode upon successful completion of the number of specified calibration points. To specify a different number of pH calibration points see Section 5. 6. Additional notes: A single point (offset) calibration is only allowed with pH 7. 00 or pH 6. 86 buffers. When the first calibration value is accepted during a new calibration, all prior calibration values are erased. at any time to abort calibration and return to measurement 3. 2 Temperature Calibration The thermistor sensor used for automatic temperature compensation and measurement is both accurate and stable, so require frequent calibration isn't required. Temperature calibration is recommended upon electrode replacement, whenever the temperature reading is suspect, or if matching against a certified thermometer is desired. 1) Connect the temperature probe to the meter and place into a solution with a known accurate temperature such as a constant temperature bath. Note: To adjust the manual temperature compensation (MTC) value, do not connect the temperature probe. 2) Press as needed to select pH or mV/R. mV. 3) Press followed by . The primary display shows the measured temperature while the secondary display shows the factory default temperature. The meter allows an adjustable maximum value of ± 5ºC º (or ± 0. 9 F) from the factory default temperature. 5 3. 3 Millivolt (mV) Offset Adjustment Oxidization Reduction Potential (ORP or Redox) is not a precise measurement, but is useful as a relative indicator. As such, mV offset adjustment is not meant to enhance accuracy, but rather to make readings comparable to a reference. Commercial ORP solutions are often used as a check standard in which a meter/electrode system are verified to be close to a given value, instead of being used as a calibration standard in which adjustments are made in an attempt to match the ORP value. 1) Connect an ORP electrode and press (or R. mV). as needed to select mV 2) Dip the ORP electrode into a solution with a known mV value (i. e. Zobel, Light's, quinhydrone, or iodidetriiodide) and stir. The primary display shows the relative millivolt value (R. mV) while the secondary display shows the factory default mV value. [. . . ] 5. 3 P3. 0 ConF (Configuration) Press . 5. 4 P3. 1 rdY (Ready / Stability Indicator) Press . to choose READY "On", READY "OFF", or Press or Auto HOLd. Press to confirm. 5. 5 P3. 2 ºCºF (Celcius Or Fahrenheit) Press Press Press . or to select ºC or ºF. to confirm. 9 5. 6 P3. 3 buFF (pH Buffers & Calibration Points) Press . Press or to select "USA" or "NIST" buffer group (pH mode only). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS PH 700

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS PH 700 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag