User manual EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER. We hope that this EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER user guide will be useful to you.

Lastmanuals help download the user guide EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER.


Mode d'emploi EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER
Download
Manual abstract: user guide EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER

Detailed instructions for use are in the User's Guide.

[. . . ] Note polarity keypad (shown in battery) compartment and in picture at right). Recalibrate tester after battery change. Error Messages: bAT Weak batteries ­ replace Er1 Wrong or bad buffer value, or electrode is failing. Or, Ur Over range / under range signal, or electrode is failing. Warranty: The waterproof pHScan BNC is warranted against defects in materials and workmanship for a period of 24 months from the date of purchase. [. . . ] If repair, adjustment or replacement is necessary and has not been the result of abuse or misuse within the warranty period, please return the tester ­ freight pre-paid ­ and correction will be made without charge. Out of warranty products will be repaired on a charge basis. Return of Items: Authorization must be obtained from your Distributor before returning items for any reason. When applying for authorization, please include information regarding the reason the item(s) are to be returned. Note: We reserve the right to make improvements in design, construction and appearance of products without notice. Prices are subject to change without notice. Microprocessor based pH Tester that floats! 68X247780 11/01 Rev 0 Waterproof pHScan BNC Microprocessor-based Pocket pH Tester Connecting your electrode: To connect the tester to your electrode, align the posts of the tester's BNC connector with the slots on the electrode connector. Push together and twist the electrode connector 1/2 turn until it clicks into place. Buffer Set selections: To choose USA (pH 4. 01, 7. 00, 10. 01) or NIST (pH 4. 01, 6. 86, 9. 18) buffers: 1. With tester off, hold HOLD/CON key while pressing ON/OFF key. A dry electrode will give fluctuating reading while it re-hydrates in a buffer, causing errors. pH Testing: 1. Remove cap or storage bottle from the electrode and press the ON/OFF button to switch tester on. Dip the electrode about 2 cm into the test solution. Stir once and let the reading stabilize. Note the pH or press HOLD/CON button to freeze the reading. Press HOLD/CON again to release the reading. If you do not press a button for 8. 5 minutes the tester will automatically shut off to conserve batteries. Instrument Maintenance: · Rinse the electrode with tap water or electrode storage solution after each measurement. [. . . ] If you do not press a button for 8. 5 minutes the tester will automatically shut off to conserve batteries. Instrument Maintenance: · Rinse the electrode with tap water or electrode storage solution after each measurement. · Periodic soaks in warm pH 4 buffer will help remove contaminants. · When finished using electrode, fill electrode cap with tap water or electrode storage solution and replace cap. Choose cabled or direct connect electrodes Lanyard connection Twist-off battery compartment · All push button operation · Displays measured units for clarity · Fast, stable, repeatable readings · Available through authorized distributors Specifications Range Resolution Accuracy Calibration WP pHScan BNC 0. 00 to 14. 99 pH 0. 01 pH ±0. 02 pH up to 3 points (pH 4. 01; 7. 00; 10. 01 or 4. 01; 6. 86; 9. 18) Operating temperature: 32 to 122 °F/0 to 50 °C Special Functions: On/Off, HOLD; CA (Calibration); CO (Confirm display); Autobuffer recognition; auto-shutoff after 8. 5 min. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EUTECH INSTRUMENTS WATERPROOF TDSCAN 4 CONDUCTIVITY TESTER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag