User manual EXAR XR-2206

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual EXAR XR-2206. We hope that this EXAR XR-2206 user guide will be useful to you.

Lastmanuals help download the user guide EXAR XR-2206.


Mode d'emploi EXAR XR-2206
Download
Manual abstract: user guide EXAR XR-2206

Detailed instructions for use are in the User's Guide.

[. . . ] 1. 03 2 XR-2206 AMSI STO MO VCC TC1 TC2 TR1 TR2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 SYMA2 SYMA1 WAVEA2 WAVEA1 GND SYNCO BIAS FSKI AMSI STO MO VCC TC1 TC2 TR1 TR2 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 SYMA2 SYMA1 WAVEA2 WAVEA1 GND SYNCO BIAS FSKI 16 Lead PDIP, CDIP (0. 300") 16 Lead SOIC (Jedec, 0. 300") PIN DESCRIPTION Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Symbol AMSI STO MO VCC TC1 TC2 TR1 TR2 FSKI BIAS SYNCO GND WAVEA1 WAVEA2 SYMA1 SYMA2 I I I I I I O O I O O Type I O O Description Amplitude Modulating Signal Input. This output is a open collector and needs a pull up resistor to VCC. 1. 03 3 XR-2206 DC ELECTRICAL CHARACTERISTICS Test Conditions: Test Circuit of Figure 2 Vcc = 12V, TA = 25°C, C = 0. 01mF, R1 = 100kW, R2 = 10kW, R3 = 25kW Unless Otherwise Specified. S1 open for triangle, closed for sine wave. XR-2206M/P Parameters General Characteristics Single Supply Voltage Split-Supply Voltage Supply Current Oscillator Section Max. [. . . ] 1. 03 7 ÁÁÁÁ ÁÁÁÁ ÁÁÁ Distortion (%) Distortion (%) C = 0. 01mF Trimmed For Minimum Distortion At 30 KW 4 ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎ 4V 4V 0 VCC / 2 DC Voltage At Pin 1 R=3KW VOUT =0. 5VRMS Pin 2 RL=10KW ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÁÁÁÁÁÁÁ ÎÎÎÎÎÎÎÎÎÎÎÎ ÁÁÁÁÁÁÁ ÎÎÎÎÎÎÎÎÎÎÎÎ ÁÁÁÁÁÁÁ ÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎ ÁÁÁÁÁ ÁÁÁÁÁ ÁÁÁÁÁ ÁÁÁÁÁ ÁÁÁÁÁ ÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁ Normal Output Amplitude XR-2206 3 C=0. 01mF 2 Frequency Drift (%) 1 R=200KW 0 R=10KW R=2KW R=1KW -2 R=1KW -25 0 25 50 75 100 -3 -50 IC R=1MW Sweep Input Rc + VC R IB IT Pin 7 or 8 R=1MW R=2KW R=10KW R=200KW -1 + 3V 12 Ambient Temperature (C°) Figure 9. Frequency Drift versus Temperature. VCC 1 5 C 6 9 7 8 Current Switches +1 VCO 2M R1 1K R Figure 11. Circuit tor Sine Wave Generation without External Adjustment. 1. 03 8 ÁÁ VCC 125 Figure 10. Circuit Connection for Frequency Sweep. 1mF 4 16 Mult. And Sine Shaper 15 14 13 2 11 10 + 1mF + 10mF VCC 12 3 R3 50K XR-2206 10K S1 200 Triangle Or Sine Wave Output Square Wave Output S1 Closed For Sinewave 5. 1K 5. 1K XR-2206 VCC 1mF 4 1 5 1 F= RC C 6 9 R1 7 8 Current Switches +1 VCO 16 Mult. And Sine Shaper 15 14 13 2 11 10 + 1mF 12 3 R3 50K + 10mF VCC 5. 1K 5. 1K Symmetry Adjust 25K RB S1 Closed For Sinewave S1 RA 500 Triangle Or Sine Wave Output Square Wave Output 10K VCC 2M 1K R XR-2206 Figure 12. Circuit for Sine Wave Generation with Minimum Harmonic Distortion. (R3 Determines Output Swing - See Figure 3) VCC 1mF 1 5 >2V <1V F1 F2 R1 R2 F1=1/R1C F2=1/R2C C 6 9 7 8 VCO 4 16 Mult. And Sine Shaper 15 14 13 Current Switches +1 2 11 10 12 + 1mF 3 XR-2206 200 FSK Input FSK Output R3 50K + 10mF VCC 5. 1K 5. 1K Figure 13. 1. 03 9 XR-2206 VCC 1 f+ 2 C R1 ) R2 16 VCO 1mF 4 1 5 C 6 9 R1 R2 7 8 Current Switches +1 Mult. And Sine Shaper Duty Cycle = R1 R1 ) R2 15 14 13 2 11 Sawtooth Output Pulse Output 5. 1K + 10mF VCC 10 + 12 3 R3 24K XR-2206 1mF VCC 5. 1K 5. 1K Figure 14. Circuit for Pulse and Ramp Generation. Frequency-Shift Keying The XR-2206 can be operated with two separate timing resistors, R1 and R2, connected to the timing Pin 7 and 8, respectively, as shown in Figure 13. Depending on the polarity of the logic signal at Pin 9, either one or the other of these timing resistors is activated. If Pin 9 is open-circuited or connected to a bias voltage 2V, only R1 is activated. Similarly, if the voltage level at Pin 9 is 1V, only R2 is activated. Thus, the output frequency can be keyed between two levels. f1 and f2, as: f1 = 1/R1C and f2 = 1/R2C For split-supply operation, the keying voltage at Pin 9 is referenced to V-. Output DC Level Control The dc level at the output (Pin 2) is approximately the same as the dc bias at Pin 3. In Figure 11, Figure 12 and Figure 13, Pin 3 is biased midway between V+ and ground, to give an output dc level of V+/2. Rev. 1. 03 10 APPLICATIONS INFORMATION Sine Wave Generation Without External Adjustment Figure 11 shows the circuit connection for generating a sinusoidal output from the XR-2206. The potentiometer, R1 at Pin 7, provides the desired frequency tuning. [. . . ] 1. 00 D 16 9 E 1 8 H C Seating Plane e B A1 L A INCHES SYMBOL A A1 B C D E e H L MIN 0. 093 0. 004 0. 013 0. 009 0. 398 0. 291 MAX 0. 104 0. 012 0. 020 0. 013 0. 413 0. 299 MILLIMETERS MIN 2. 35 0. 10 0. 33 0. 23 10. 10 7. 40 MAX 2. 65 0. 30 0. 51 0. 32 10. 50 7. 60 0. 050 BSC 0. 394 0. 016 0° 0. 419 0. 050 8° 1. 27 BSC 10. 00 0. 40 0° 10. 65 1. 27 8° Note: The control dimension is the millimeter column Rev. 1. 03 15 XR-2206 NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user's specific application. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EXAR XR-2206

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual EXAR XR-2206 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag