User manual FENDER BXR 200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FENDER BXR 200. We hope that this FENDER BXR 200 user guide will be useful to you.

Lastmanuals help download the user guide FENDER BXR 200.


Mode d'emploi FENDER BXR 200
Download
Manual abstract: user guide FENDER BXR 200

Detailed instructions for use are in the User's Guide.

[. . . ] The rugged power amplifier is designed to give years of reliable service under all conditions. It is equipped with our exclusive DELTACOMPTM adaptive compressor system. With DELTACOMP, it is practically impossible to clip (distort) the power amplifier. The apparent release time of the compressor is short, yet distortion at low frequencies is kept to a minimum. [. . . ] A lower number corresponds to a slower rate of sweep. C. D. +12 0 -12 K. CHORUS INDICATOR - This LED is illuminated when the chorus is active. The intensity of the LED is modulated by the chorus sweep low frequency oscillator (LFO) to give a visual indication of the sweep rate. DEPTH - Adjusts the intensity of the chorus effect. A lower setting will introduce a subtle yet distinct effect whereas a higher setting will create a more dramatic effect. With both the RATE (item J) and DEPTH controls set midway or higher, a variety of vibrato/tremolo type effects can be achieved. L. button "OUT, " DELTACOMP is OFF. With the button "IN, " DELTACOMP is ON, and a special ASYMMETRIC LIMITER circuit is enabled. The Asymmetric Limiter is designed to "smooth-out" any distortion caused when the power amplifier clips by adding even-order harmonics. DELTACOMP INDICATOR LED - This LED, when lit, indicates that the power amplifier has reached full power and that either DELTACOMP or LIMITING has occurred, depending on the position of the switch. The unit may seem louder without DELTACOMP, since the power amp will be allowed to go into clipping. With DELTACOMP on, your volume level will be rather loud before the compressor turns on; this is normal. M. SELECT - Activates the chorus generating circuitry for a fuller, more colorful sound. NOTE: This switch disables the Chorus Select FOOTSWITCH (item N). FOOTSWITCH - Plug-in connection for remote footswitch to switch the CHORUS on and off. For proper operation of the footswitch, the CHORUS SELECT (item M) switch should be out. NOTE: Any good quality patch cord will work with the remote footswitch, however a speaker grade cord is preferable to a coax guitar cord when it is available. DELTACOMP - DELTACOMP is Fender's exclusive compressor circuit used in the BXR 200. This circuit is designed to prevent the power amplifier section from clipping and causing unwanted distortion. POWER INDICATOR - When this LED is illuminated, the BXR 200 unit is receiving power. POWER - Turns the BXR 200 unit "ON" or "OFF. " LINE OUTPUTS BXR 200 REAR PANEL The above diagram corresponds to the BXR 200 HEAD. Orientation differs slightly on the BXR 200 COMBO. [. . . ] (Eliminate any effect pedals and try another guitar cord. ) If, after checking all of the above, the system is still not performing correctly, consult your Fender Service Dealer. BXR 200 SPECIFICATIONS Part Number: 100V 120V 230V 230V UK 240V AUSTRALIA PR286 100V Version: 120V Version: 230V Version: 240V Version: 100VAC, 50/60Hz, 540W 120VAC, 60Hz, 540W 230VAC, 50Hz, 540W 240VAC, 50Hz, 540W COMBO 022-4475-000 022-4405-000 022-4465-000 022-4445-000 022-4435-000 HEAD 022-4476-000 022-4406-000 022-4466-000 022-4446-000 022-4436-000 Type Specification: Power Requirements: POWER AMPLIFIER SECTION: Power output: Rated load impedance: Distortion at 200 watts: Sensitivity: Input impedance: DELTACOMP (tm) range: PREAMP SECTION: Input impedance: Input 1 - Greater than 420 k (typically greater than 1 M in the passband) Input 2 - 136 k Input 1 - 2. 2 mV Input 2 - 4. 4 mV 200W R. M. S. 4 Less than . 1% @ 1 kHz, below compression Less than 1% @ 1 kHz, maximum compression 1. 03V R. M. S. 22 k 20 dB Sensitivity for 200 W: GAIN at maximum, all tone controls at "0" detent, no enhancement activated. Shelving tone controls: Graphic equalizer: PHYSICAL SPECIFICATIONS: LOW +/- 12 dB at 60 Hz HIGH +/- 12 dB at 10 kHz +/- 12 dB at 80, 140, 250, 450, 800, 1. 4k, 2. 5k, 4. 5k, and 8 kHz. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FENDER BXR 200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FENDER BXR 200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag