If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46170300. We hope that this FIELD CONTROLS 46170300 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46170300.


Mode d'emploi FIELD CONTROLS 46170300
Download
Manual abstract: user guide FIELD CONTROLS 46170300

Detailed instructions for use are in the User's Guide.

[. . . ] Mount the switch box onto the appliance 2 to 3 inches away from the draft hood using two sheet metal screws. The probe should be directed towards the draft hood. (See Figure 1) An alternative mounting method is to mount the switch directly onto the draft hood. [. . . ] (See Diagram B) 750 MILLIVOLT SYSTEM Wire the TSP-1 thermal switch in series with one side of the thermostat circuit (See Diagram C) or pilot generator circuit. Light the appliance burner in accordance with manufacturer's instructions. Operate the appliance to determine that the appliance will operate continuously. Adjust thermostat so the appliance burner is shut off. Allow system to cool down, then remove the vent pipe connection near the appliance. Block the appliance vent outlet with a noncombustible material. Adjust thermostat control to call for heat. Allow approximately 2 minutes for the system flue gases to back up and the gas burner to shut off. Push the reset on the spillage switches, then relight appliance and perform Steps 3 & 4 again. Re-connect vent pipe connection and cycle system 2 to 3 times to ensure continuous operation. NOTE: Shutdown of appliance burner should not be more than 10 minutes. PRE-INSTALLATION INSPECTION INSTRUCTIONS FOR EXISTING APPLIANCES RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION BY THE NATIONAL FUEL GAS CODE 54, Z223. 1 APPENDIX H: The following procedure is intended as a guide to aid in determining that an appliance is properly installed and is in a safe condition for continuing use. This procedure is predicated, on central furnace and boiler installations, and it should be Page 3 Figure 5 Figure 6 Diagram B Diagram C recognized that generalized procedures cannot anticipate all situations. Accordingly, in some cases deviation from this procedure may be necessary to determine safe operation of the equipment: a. This procedure should be performed prior to any attempt to modification of the appliance or of the installation. If it is determined there is a condition which could result in unsafe operation, the appliance should be shut off and the owner advised of the unsafe condition. [. . . ] Turn on all other fuel-gas burning appliances within the same room so they will operate at their full inputs. Follow lighting instructions for each appliance. Repeat Steps 10 through 12 on the appliance being inspected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46170300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46170300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag