User manual FIELD CONTROLS 46244900

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46244900. We hope that this FIELD CONTROLS 46244900 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46244900.


Mode d'emploi FIELD CONTROLS 46244900
Download
Manual abstract: user guide FIELD CONTROLS 46244900

Detailed instructions for use are in the User's Guide.

[. . . ] THERMOCOUPLE JUNCTION BLOCK Model: TCA-1 This device is used to attach spill switches to a 30 millivolt water heater. It is designed to be used with models GSK SERIES spill switches, TSP SERIES spill switch or SSK SERIES spill switch kits for connecting flue gas sensing spillage switches to 30 millivolt gas valves. REQUIRED ACCESSORIES 2-GSK series spill switches 6 ft. [. . . ] Hand tread the block into thermocouple port then tighten lightly with a wrench. Mount the two (2) spill switches onto the draft hood so the switches do not contact any metal. Connect the one terminal of each switch with 12 ga wire and then connect it to the thermocouple junction block. Next, connect the two remaining terminals together using a short length of 12 ga wire. Route and secure the wires to the water heater enclosure with acceptable hold down tabs, keeping the wires away from any hot surface area. SYSTEM CHECK-OUT PROCEDURE FOR GAS SPILLAGE SWITCH CONTROL 1. Block the flue pipe above the draft hood or draft diverter. Re-establish gas supply to appliance and re-light pilot. Flue gases should be emitting from draft diverter or draft hood. Note the location of the most flue gas spillage. [. . . ] CAUTION: If for any reason the system has shut down during normal operation, the cause of the system failure should be investigated and corrected before resetting the safety switch and relighting the pilot. Figure 2 Figure 1 Figure 3 Page 2 P/N 46244900 Rev A 12/00 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46244900

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46244900 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag