User manual FIELD CONTROLS 46284600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46284600. We hope that this FIELD CONTROLS 46284600 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46284600.


Mode d'emploi FIELD CONTROLS 46284600
Download
Manual abstract: user guide FIELD CONTROLS 46284600

Detailed instructions for use are in the User's Guide.

[. . . ] After the CAS comes up to speed, a pressure switch in the unit closes and allows the appliance to fire. After the heating requirement has been satisfied, the thermostat circuit will open and deactivate the burner and CAS unit. For power vented systems with a post purge device, the power venter and CAS operate for a period of time after the burner has shut off to purge remaining flue gases from the vent system. INSTALLATION SAFETY INSTRUCTIONS CAUTION: This device must be installed by a qualified installer in accordance with the manufacturer's installation instructions. [. . . ] If the point falls near the leftward border of a region, then the VRV balance weight should be adjusted to it's minimum position. This corresponds to turning the balance weight screw as far counterclockwise as possible. EXAMPLE: A gas fired appliance firing at 100, 000 BTU/hr where the CAS unit needs to be placed 30 equivalent feet from the intake hood. From Diagram A or B, the point at 100, 000 BTU/Hr on the "Gas Firing Rate" scale and 30 equivalent feet falls in the "4 inch Duct, Hood, and Orifice Ring" region. The point is approximately 2/3 of the horizontal distance between the left and right boundary of the region. The left boundary is the edge of the graph, the right boundary is the diagonal line that says "4 inch Duct, Hood & Orifice Ring. " Therefore, place the Orifice Ring into the inlet of the CAS so that it sits on the ledge above the fan. It does not matter which way the Orifice Ring is turned as long as it is pushed down against the ledge completely. Use 4" diameter pipe to connect the vent hood and the CAS unit. Install a VRV and the included 4x6 inch Increaser on top of the CAS unit and adjust the balance weight to 2/3 of the distance of it's full adjustment range from it's minimum setting. The minimum setting is with the balance weight turned all of the way counterclockwise. Table 1 Total Input of Appliance CAS-4, 4mV Gas (BTU/hr) 50, 000 75, 000 100, 000 125, 000 150, 000 175, 000 200, 000 225, 000 250, 000 300, 000 350, 000 400, 000 450, 000 Maximum Equivalent Feet of Installation 4" Duct And Hood W/Restrictor HI 300 300 300 300 174 99 52 20 NA NA NA NA NA LOW 300 300 300 220 108 48 14 NA NA NA NA NA NA 4" Duct And 4" Intake Air Hood HI 300 300 300 300 232 152 102 68 45 16 NA NA NA LOW 300 300 300 220 118 63 32 13 NA NA NA NA NA 6" Duct And 6" Intake Air Hood HI 300 300 300 300 300 300 300 300 300 300 193 109 56 LOW 300 300 300 300 300 300 300 239 150 53 8 NA NA Page 3 HIGH SPEED SIZING CHART OIL INPUT FIRING RATE (gallons per hour) (1 gallon oil/hr = 140, 000 BTU/hr) 0. 00 300 0. 50 1. 00 1. 50 2. 00 2. 50 3. 00 3. 50 250 MAX. EQUIVALENT DUCT LENGTH (ft. ) 6" Duct & Hood 4" Duct & Hood 4" Duct, Hood, & Orifice 200 150 100 50 0 0 50 100 150 200 250 300 350 400 450 500 550 GAS INPUT FIRING RATE (1000 BTU/hr. ) Diagram A LOW SPEED SIZING CHART OIL INPUT FIRING RATE (gallons per hour) (1 gallon oil/hr = 140, 000 BTU/hr. ) 0. 00 300 0. 50 1. 00 1. 50 2. 00 2. 50 250 MAX. EQUIVALENT DUCT LENGTH (ft. ) 6" Duct & Hood 4" Duct & Hood 4" Duct & Hood w/ Orifice 200 150 100 50 0 0 50 100 150 200 250 GAS INPUT FIRING RATE (1000 BTU/hr. ) 300 350 400 Diagram B Page 4 INSTALLATION PLACEMENT OF THE CAS UNIT The motorized CAS unit should be located on a flat horizontal surface within the same space as that3 feet of the appliance and within 3 feet of the combustion air intake as possible. Two mounting brackets are provided for securing the unit against a solid structure, such as a wall, column, or the side of the appliance itself. Use the included screws to attach the brackets to the CAS housing as shown in Figure 3. Secure the brackets to a solid structure with appropriate fasteners. It is not required to use the brackets as long as the unit is located so that it may not be bumped, moved, or tipped over. The optional Vacuum Relief Valve (VRV) should be placed directly on the air inlet of the CAS unit if using 6". (See Figure 1) Refer to Diagram A to determine if the VRV is needed. The VRV should be oriented so that the axis of the swinging gate is horizontal. ASSEMBLING THE WEIGHTS ON THE VRV Refer to Figure 2 to assemble the weight assembly, hex nut, and knurled nut to the VRV gate. After the weight is correctly positioned, tighten the hex nut against the gate to prevent the weight assembly from moving during operation. INTAKE AIR HOOD LOCATION The 4" galvanized vent hood should be located on an outside wall maintaining minimum clearances to other intake and exhaust vents in accordance with the National Fuel Gas Code, ANSI Z223. 1, manufacturer's recommendations and/or local codes which are applicable. [. . . ] The references to various series of control kits implies that any kit in that series may be used. If further information or additional wiring diagrams are needed please consult Field Controls' technical support. INTERNAL WIRING CONNECTIONS FOR THE CAS UNIT Refer to Figure 4 for the internal wiring of the CAS-4 unit. EXTERNAL WIRING CONNECTIONS Wire Key MOTOR MANUFACTURER McLean Engineering All Others WIRE COLOR W1 Black Brown W2 Blue Black W3 Brown Blue Figure 4 Refer to Figures 5-12 for appropriate wiring method. Figure 5 ­ Chimney Vent Single 24V Furnace Page 6 Figure 6 ­ Power Vent Single 24V Furnace Figure 7 ­ Chimney Vent 24V Furnace and 30mV Water Heater with CK-20FV or CK-20FG Page 7 Figure 9 ­ Power Vent Single 24V Boiler Figure 8 ­ Chimney Vent 24V Boiler Page 8 Figure 10 ­ Chimney Vent Two 24V Gas Appliances With CAC-24 Page 9 Figure 11 ­ One Power Venter Two 24V Gas Appliances With DIP-1 Page 10 Figure 12 - Figure 12 shows how the DIP-1 should be attached to the CAS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46284600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46284600 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag