User manual FIELD CONTROLS 46330800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46330800. We hope that this FIELD CONTROLS 46330800 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46330800.


Mode d'emploi FIELD CONTROLS 46330800
Download
Manual abstract: user guide FIELD CONTROLS 46330800

Detailed instructions for use are in the User's Guide.

[. . . ] Do not reconnect the oil line (per E-F). The solenoid valve must be aligned as shown to prevent interference with the Air BootTM. Remove the two ¼" bolts holding the oil pump to the burner housing. [. . . ] Mount the VRV tee assembly or 90° elbow onto the Air BootTM intake. Fasten using three (3) sheet metal screws on all joints (See Figure 5). Assemble the VRV balance weight onto the gate. Then attach lock nut and knurl nut (See Figure 6). Mount the VRV assembly onto the tee and fasten with the supplied screw and nut in collar tabs. To ensure proper operation, Check the gate for being level across the pivot points and plumb (See Figure 7). Refer to Figure 8 for general installation layout. AIR DUCT AND AIR INTAKE HOOD (See Figure 8) 1. Mount the air intake hood through an outside wall. It must be at least 12" (inches) ABOVE grade or snow line. Locate the air intake hood at least 3' (feet) BELOW (or 6 feet horizontally from) any appliance VENT termination. When the appliance is sidewall vented, locate the air intake hood on the same side of the building as the appliance vent outlet. Always mount the air hood with the intake pointed down. To install the air intake hood, cut a 4 ¼" hole through the side of the building. Slide the hood through the wall and fasten with appropriate screws. Seal around the exterior plate with an exterior rated caulk, silicone sealant or equivalent. Locate the air hood so the air piping length doesn't exceed the limits below: Number of Elbows 2 to 4 5 6 7 Maximum Length of Air Pipe 35 Feet 28 Feet 21 Feet 14 Feet Figure 6 Figure 5 8. Construct the air duct piping with 4" diameter dryer vent or aluminum or galvanized steel pipe, using as few elbows as possible. [. . . ] Set over fire draft to appliance manufacturers' specifications (typically -. 02" of water). Secure air control knob with indicator bracket. If draft levels are not obtainable or controllable, use standard industry methods to control the draft or call the Field Controls Tech Line at 1-800-742-8368 for more information. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46330800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46330800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag