If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46422800. We hope that this FIELD CONTROLS 46422800 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46422800.


Mode d'emploi FIELD CONTROLS 46422800
Download
Manual abstract: user guide FIELD CONTROLS 46422800

Detailed instructions for use are in the User's Guide.

[. . . ] Locating the Air Booster near the outlet end of a problem branch duct will provide the best performance. The Air Booster is designed to operate in round ducts 6-inches in diameter or larger and rectangular ducts 6-inches wide by 6-inches deep or larger. CAUTION: Do not install the Air Booster where the air temperature o within the duct exceed 180 F. [. . . ] Position the Air Booster so the fan blade does not rub against the inside surface of the duct. Mark on the duct the location of the 6-hole positions in the base plate. Remove the Air Booster and drill 1/8-inch diameter holes through the duct pipe where indicated. Remove center knockout from the installer supplied outlet box bottom. (See Figure 2A) Before installing Air Booster into the duct pipe, fasten the outlet box onto the base plate with the #10-32 UNF screws and nuts provided. Insert the Air Booster into the cut slot of the duct pipe. Make sure the fan blade is pointed toward the outlet of the duct. Secure the Air Booster onto the duct with the sheet metal screws provided. (See Figure 3A or 3B) Page 2 UNIT WIRING INSTRUCTIONS ELECTRICAL DATA VOLTS 120 VAC AMPS . 60 HZ 60 WATTS 35 RPM 3000 THERMAL OR IMPEDANCE PROTECTION YES A permanent wiring method must be used for power connection. It is recommended that a minimum size of 14 AWG wire o o for electrical supply connections and wiring should be suitable for 90 C (194 F) temperature. The Air Booster should be wired with an overcurrent protection device (fuse or circuit breaker) rated 15 amperes or less. Wiring method should be in accordance with the National Electrical Code and any local code requirements. CAUTION: Disconnect electrical power before wiring. Do not route electrical wiring along heated duct pipes. 1 Controlling the Air Booster through a standard on/off wall switch. (See Figure 4 for wiring diagram) This method allows for manual control of the Air Booster unit in the area desired. [. . . ] NOTE: All wire splice connections should be made within an electrical junction box. MAINTENANCE CAUTION: Disconnect electrical power supply before performing maintenance. Periodic removal and cleaning of the Air Booster unit is recommended for forced central heating/air conditioning systems. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46422800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46422800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag