User manual FIELD CONTROLS 46483500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIELD CONTROLS 46483500. We hope that this FIELD CONTROLS 46483500 user guide will be useful to you.

Lastmanuals help download the user guide FIELD CONTROLS 46483500.


Mode d'emploi FIELD CONTROLS 46483500
Download
Manual abstract: user guide FIELD CONTROLS 46483500

Detailed instructions for use are in the User's Guide.

[. . . ] Safety inspection of a venting system should be performed before and after installing a venting system on an existing or new appliance. Procedures to follow are the latest version of those recommended by the National Fuel Gas Code, ANSI Z223. 1, UL-726, NFPA31, CSA B139, CSA B140. 0. 03 appliance manufacturer's recommendations, or refer to the General Installation Inspection section of this manual. Plan the vent system layout before installation to avoid the possibility of accidental contact with concealed wiring or plumbing inside walls. INSTALLATION OF FDVS DIRECT VENT SYSTEM INSTALLATION OF THE VENT TERMINATION (c) (a) (b) (e) (c) (c) (g) Diagram A 1. Remove vent system components from box and inspect for damage. [. . . ] If the siding is greater than 1/2" thick use a spacer plate or board behind the vent termination mounting plate. (See Figure 2) Page 2 INSTALLATION OF THE VENT TERMINATION COMBUSTION AIR TEE 1. Assemble the combustion air tee assembly body to the vent termination outer pipe, and rotate to the desired position. Attach the tee assembly body to the vent termination outer pipe with at least 3 sheet metal screws evenly spaced apart (not included). After completing assembly of the vent pipe to the termination inner pipe (Fig. 4), apply the supplied high temperature sealant to the cover pan around the inner pipe, around the joint between the collar and the Tee assembly, and seal or tape the joint from the FDVS Termination to the Tee assembly. NOTE: The tee may be rotated into any position so that the collar is in a convenient orientation. CLEARANCE TO COMBUSTIBLES: FDVS Termination: 0", FOVP Flexible Oil Vent Pipe: 1". These clearances are to maintained unless superceded by the appliance manufacturer's installation instructions or by National and/or local codes (see Step 3). CONNECTING THE VENT PIPE FROM THE FDVS TO THE APPLIANCE 1. Figure 3 ­ Top View The venting system should be installed and supported in accordance with the latest version in the USA of the National Fuel Gas Code ANSI Z223. 1, UL-726, National Fire Protection Association NFPA31, and in Canada CSA B140, CSA B139 Installation Code or in accordance with any other local codes or the authority having jurisdiction. Where requirements for venting differ the most stringent standard requirements shall apply. A vent pipe connector, designed for positive pressure venting, shall be supported for the design and weight of the material employed, to maintain clearances, prevent physical damage and separation of joints. All joints MUST be sealed, for positive vent pressure, to prevent flue gas leakage into the structure. Route the vent pipe from the appliance to the vent termination using the minimum number of bends as possible. The last horizontal section of the vent pipe should have a slight downward slope from the appliance to the vent termination. For clearances to combustible materials and other installation requirements, refer to the National Fuel Gas Code ANSI Z223. 1, UL-726, NFPA31, CSA B140, CSA B139 and/or any applicable local codes or appliance manufacturer's installation instructions. Refer to the appliance manufacturer's specifications for maximum length of vent pipe run. Unless otherwise specified by the appliance manufacturer, use the same size diameter pipe as the exhaust outlet on the appliance to connect to the vent termination inlet. Use a reducer or increaser, if necessary, at the vent termination to connect the vent pipe. Support the Flexible Oil Vent Pipe (FOVP) at regular intervals of maximum 36" spacing with appropriate strapping or hangers, per National and local code requirements. [. . . ] Be sure to properly replace the panel. Page 3 1. FIELD CONTROLS DIRECT VENT SYSTEMS VENT PIPE ASSEMBLY Figure 4 APPLIANCE ADAPTER INSTALLATION: 1. Apply a bead of sealant to appliance collar approx. Remove all oil and grease from the inside of the appliance adapter, and apply a bead of sealant to inside of adapter ½" from end (Figure 5). With a twisting motion, assemble the appliance adapter onto the appliance collar. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIELD CONTROLS 46483500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIELD CONTROLS 46483500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag