User manual FIREX G-6GC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FIREX G-6GC. We hope that this FIREX G-6GC user guide will be useful to you.

Lastmanuals help download the user guide FIREX G-6GC.


Mode d'emploi FIREX G-6GC
Download
Manual abstract: user guide FIREX G-6GC

Detailed instructions for use are in the User's Guide.

[. . . ] 120V AC Ionization Smoke Alarm 110-427K MODEL G-6, H, GC PG40 and FXW-R L STA TE IS OF TIN CALIF G A L O R NI E E FIR E M AR S HA PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with the occupier (or, in the case of a house in multiple operation, with the owner) The ionization type alarms are generally more effective at detecting fast, flaming fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include flammable liquids or paper burning in a waste container. The photoelectric type alarms are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. [. . . ] See TESTING THE SMOKE ALARM. INTERCONNECTING SMOKE ALARMS !WARNING: This smoke alarm should be installed only by a qualified electrician. Smoke alarm wiring to be used shall be in accordance with the provisions of Article 210 and 760 of the National Electrical Code, ANSI/NFPA 70, and any local codes that may apply. Interconnect wire location shall be in accordance with NEC Article 300. 3b. IMPORTANT: The model FXW-R is a direct replacement for Firex models FX1014, FX1020, FX1106 and FXW-1A. Model FXW-R cannot be interconnected with any other smoke alarm. IMPORTANT: Do not interconnect Firex smoke alarms with yellow interconnect wires to Firex smoke alarms with orange interconnect wires. IMPORTANT: Do not attempt to interconnect with any other type of device or manufacturer's brand. · As many as 12 Model GC & PG40 (6 for Model G-6) smoke alarms may be interconnected. · As many as 12 Model FXW-R smoke alarms may be interconnected. · Connect smoke alarms to a dedicated AC branch circuit. If local codes do not permit, be sure the neutral wire is common to both phases. WHITE YELLOW* BLACK *(Orange on Model FXW-R) WHITE YELLOW* BLACK WHITE BLACK TO NEUTRAL TO 120 VAC LED INDICATORS This smoke alarm features an LED indicator which can be seen through the Push-to-Test button. The LED indicates the following: Blinks once a minute Blinks once a second Blinks once approximately every 10 seconds -- indicating normal operation. -- smoke alarm senses smoke and simultaneously sounds an audible alarm. -- False Alarm Control (FAC) feature activated (model GC only). OFF -- another smoke alarm in the (Interconnected system only): network has sensed smoke and is signalling this alarm. FALSE ALARM CONTROL Model GC features a False Alarm Control that, when activated, quiets unwanted alarms for up to 15 minutes. To use the False Alarm Control: Press and release the test button during an unwanted alarm. The alarm should stop within ten seconds. This means the smoke alarm is in False Alarm Control. If the smoke alarm does not go into False Alarm Control and continues to sound its loud alarm horn, or if it initially goes into False Alarm Control then resounds the alarm, the smoke is too heavy and a dangerous situation could exist--take emergency action. NOTE: In an interconnected circuit, False Alarm Control must be activated on the initiating unit. 5 TESTING THE SMOKE ALARM !WARNING DANGER: If alarm horn sounds, and smoke alarm is not being tested, the smoke alarm is sensing smoke. THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION. · Test each smoke alarm weekly to be sure it is installed correctly and operating properly. · Test smoke alarms upon returning from vacation. [. . . ] LED blinks and alarm beeps simultaneously every 60 seconds. LED blinks and 30 seconds later alarm beeps ­ repeats at 60 second intervals. Smoke alarm sounds unwanted alarms when residents are cooking or taking showers. SOLUTION Check that AC power is turned on. Battery is low ­ REPLACE IT IMMEDIATELY!REPLACE OR RETURN FOR REPAIR IMMEDIATELY! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIREX G-6GC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FIREX G-6GC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag