Manual abstract: user guide FLUKE OPG1-30000-AF

Detailed instructions for use are in the User's Guide.

[. . . ] 33A6-4-30-1 OPG1-30000-AFTM Oil Pressure Generator/Controller Operation and Maintenance Manual NSN 6685-01-470-8667 (1 of 2) 1 August 2000 ©2000 DH Instruments, Inc. OPG1TM Operation and Maintenance Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High pressure systems should be assembled and operated only by personnel who have been instructed in proper safety practices. © 2000 DH Instruments, Inc. Information in this document is subject to change without notice. [. . . ] System Schematic ©2000 DH Instruments, Inc. Page 20 OPG1TM Operation and Maintenance Manual 3. 2 OPERATIONAL FUNCTIONS All OPG1 operational functions are accessed from the instrument front panel. Sections 3. 2. 1 to 3. 2. 6 detail the various functions. 1 2 3 4 1. 8. PDVV Drive Air/Test Oil Pressure Gauge PDVV Piston Position Indicator Pump Drive Air/Inlet Oil Pressure Gauge Pump Drive Air Set Regulator Test Inlet Valve Knob PDVV Increase Fast and Slow Buttons PDVV Decrease Fast and Slow Buttons Test Outlet Valve Knob 8 7 6 5 Figure 6. Front Panel 3. 2. 1 SETTING INLET PRESSURE, DRIVE SET REGULATOR ADJUSTMENT Numerical references in this section refer to Section 3. 2, Figure 6. The DRIVE SET regulator (4) is a self venting regulator that sets the pneumatic drive pressure to the hydropneumatic pump. This determines the oil pressure that the pump will generate before stalling and that is available on demand when the INLET valve (5) is opened. The PUMP DRIVE gauge (3) indicates the pump drive pressure on its inner dial and the corresponding pump output oil pressure on its outer dial (BLUE numbers). Use the outer BLUE indication to predict the maximum pressure that will be generated when the inlet valve is opened. Page 21 ©2000 DH Instruments, Inc. OPG1TM Operation and Maintenance Manual With the INLET valve (5) closed, use the DRIVE SET regulator (4) and the PUMP DRIVE gauge (3) indication to set the desired maximum pump output pressure. This is generally done at the beginning of a test or calibration based on the maximum pressure of the calibration. It is good practice to set the pump output pressure below the maximum pressure desired to avoid accidental overpressure. The PDVV can then be used for the final pressure adjustment at the maximum pressure (see Section 3. 2. 3). The DRIVE SET regulator sets the oil pressure output of the hydropneumatic pump. When the INLET valve is opened, this pressure can be generated very rapidly in the system connected to OPG1. Use caution in setting the pump drive pressure and always check the setting and adjust if necessary before using the INLET valve (see Sections 2. 4. 2 and 3. 2. 1). 3. 2. 2 ROUGH PRESSURE GENERATION/CONTROL, INLET AND OUTLET VALVE OPERATION Numerical references in this section refer to Section 3. 2, Figure 6. The INLET valve (5) and OUTLET valve (8) are high pressure needle valves. Their operation is highly progressive over a half-turn with mechanical stops at each end so they cannot be overtightened. The valve is turned CW to close and CCW to open. A WHITE dot on the handle body indicates its current open/close position. The INLET valve (5) controls the flow of oil from the hydropneumatic pump into the test system. When the INLET valve is closed, the pump is shut off from the test system and dead ended. When the INLET valve is open, the pump output is connected to the test system and can fill and generate pressure into the system. The OUTLET valve (8) controls the flow of oil from the test system back to the tank. [. . . ] AUTHORIZED SERVICE PROVIDERS 2000 JAN TELEPHONE, FAX EMAIL Tel 602. 431. 9100 Fax 602. 431. 9559 jbaines@dhinstruments. com Tel 31/35. 52. 54. 887 Fax 31/35. 52. 64. 560 minervaipm@compuserve. com COMPANY DH Instruments, Inc. ADDRESS 4765 East Beautiful Lane Phoenix AZ 85044-5318 USA Handelsweg 13 Postbus 76-1270 AB Huizen NETHERLANDS 2-9-1 Sengen, Tsukuba-Shi Ibaraki Prefecture 305 JAPAN NORMAL SUPPORT REGION Worldwide Minerva I. P. &M. B. V. European Union Nippon CalService, Inc. Tel 0298-55-8778 Fax 0298-55-8700 aohte@ohtegiken. co. jp Japan/Asia ©2000 DH Instruments, Inc. Page 36 OPG1TM Operation and Maintenance Manual GLOSSARY , Fast and slow , PDVV (-) valves. Used to decrease pressure and for fine pressure adjustment. Used to increase pressure and for fine pressure adjustment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE OPG1-30000-AF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE OPG1-30000-AF will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag