User manual FLUKE PPC2 AF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FLUKE PPC2 AF. We hope that this FLUKE PPC2 AF user guide will be useful to you.

Lastmanuals help download the user guide FLUKE PPC2 AF.


Mode d'emploi FLUKE PPC2 AF
Download
Manual abstract: user guide FLUKE PPC2 AF

Detailed instructions for use are in the User's Guide.

[. . . ] PPC2 AFTM Operation and Maintenance Manual © 1998, 2002 DH Instruments, Inc. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of DH Instruments, Inc. 4765 East Beautiful Lane, Phoenix AZ 85044-5318, USA. [. . . ] "DATE=yymmdd "DATE" yymmdd: The date in the numerical only format year-month-day with no spaces. The PPC2 AF has an internal real time calendar clock. It is used for date stamping calibrations. Command: "DATE=960221" Reply: "960221" ERR# 7: Missing or improper command argument(s) 3. 4. 4. 4 Decrease the pressure quickly. "DF=n" `0' Closes the fast down valves. Opening the fast down valves will cause the pressure to decrease quickly. Command: "DF=1" Reply: "DF=1" ERR# 6:The n argument is a `0' or a `1' 1. 2. 7 © 1998 DH Instruments, Inc. Page 60 4. REMOTE OPERATION DP= Purpose: Syntax: Arguments: Remarks: Example: Errors: See Also: DS= Purpose: Syntax: Arguments: Remarks: Example: Errors: See Also: DRVn (=) Purpose: Syntax: Arguments: Remarks: Example: Errors: See Also: ERR Purpose: Syntax: Remarks: Decrease the pressure a given amount using the slow speed. "DP=n" n The decrease in pressure desired (current pressure units). This can be from 0 to 2 % FS of the current transducer range. The slow speed will be used for a calculated amount of time (up to 5 seconds) to create the desired change. The PPC2 AF will not attempt to control the pressure to a target, so the change in pressure will be approximate. Command: "DP=10" Reply: "10. 00 kPa a" ERR# 6: The n argument is not within given limits. "DS=n" n `0' Closes the slow down valve. Opening the slow down valve will cause the pressure to decrease slowly. Command: "DS=1" Reply: "DS=1" ERR# 6: The n argument is a `0' or a `1' 1. 2. 7 Read or set the status of an external solenoid valve. "DRVn=x" "DRVn" n The valve to operate on. The PPC2 AF can control up to eight external valves. Valve driver #8 is reserved for the external SPLT valve. Command: "DRV3" Reply: "DRV3=1" ERR# 6: The n or x arguments are not within given limits. 3. 3. 4 Example: See Also: Read the last error message. "ERR" The "ERR" command finds out more details about an error that has occurred. [. . . ] In toggle mode the driver state will toggle each time the corresponding key is pressed. However, the total output of all the activated drivers cannot exceed one Amp. Therefore, if multiple drivers are being activated please refer to the following chart as a guide. # OF ACTIVE DRIVERS MAX CURRENT PER OUTPUT 1 2 3 4 5 6 7 8 500 mA 400 mA 275 mA 200 mA 160 mA 135 mA 120 mA 100 mA The male connector (P/N 102478) for the DRIVERS port is supplied with the PPC2 AF accessories. The following table and figure should be used as reference when building a cable to utilize the drivers port. EXTERNAL DRIVERS PIN A C E G M J K L B D F H D1 D2 D3 D4 D5 D6 D7 D8 DESCRIPTION Driver #1 (Open Collector) Driver #2 (Open Collector) Driver #3 (Open Collector) Driver #4 (Open Collector) Driver #5 (Open Collector) Driver #6 (Open Collector) Driver #7 (Open Collector) Driver #8 (Open Collector) Drivers (+ 12 V) Drivers (+ 12 V) Drivers (+ 12 V) Drivers (+ 12 V) Page 139 © 1998 DH Instruments, Inc. PPC2 AF OPERATION AND MAINTENANCE MANUAL 9. 2 SPLT CABLE AND CONNECTIONS In order to take advantage of the automatic purging feature of the PPC2 AF (see Section 3. 2. 8), the SPLT valve must be connected to the PPC2 AF's external driver #8. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUKE PPC2 AF

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUKE PPC2 AF will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag