User manual FOSTEX DV40

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FOSTEX DV40. We hope that this FOSTEX DV40 user guide will be useful to you.

Lastmanuals help download the user guide FOSTEX DV40.


Mode d'emploi FOSTEX DV40
Download

You may also download the following manuals related to this product:

   FOSTEX DV40 V 1.1 (262 ko)
   FOSTEX DV40 BROCHURE (480 ko)
   FOSTEX DV40 ETHERNET MANUAL (41 ko)
   FOSTEX DV40 OWNERS MANUAL VERSION V1.2 SUPPLEMENT (381 ko)
   FOSTEX DV40 OWNERS MANUAL VERSION V1.3 SUPPLEMENT (101 ko)
   FOSTEX DV40 OWNERS MANUAL VERSION V1.4 SUPPLEMENT (45 ko)
   FOSTEX DV40 OWNERS MANUAL VERSION V1.6 SUPPLEMENT (124 ko)
   FOSTEX DV40 OWNERS MANUAL VERSION V1.7 SUPPLEMENT (45 ko)

Manual abstract: user guide FOSTEX DV40

Detailed instructions for use are in the User's Guide.

[. . . ] 8288 486 000 DVD Master Recorder Model Operation Manual CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT. ATTENTION: CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU' AU FOND. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. "WARNING" "TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. " SAFETY INSTRUCTIONS 1. Read Instructions - All the safety and operating instructions should be read before the appliance is operated. [. . . ] You can enter up to "23H 59M 59S **F" (in which ** is one smaller than the frame rate number). 4. After editing the start time, press the [ENTER/YES] key. The start time is set and the display returns to show "Edit LTC Start?". 5. To exit the TC Setup mode, press the [EXIT/NO] key (or the [STOP] key). To check the start time, press the [DISP TIME] key repeatedly until the display shows LTC. 5-8 · Catch offset you can capture the current LTC and store it as the chase offset by the "Catch Offset" function. This function is available both during playback and while stopped. Use the jog dial (or [SKIP/CURSOR] [|<<] / [>>|] keys) to select "Catch Offset?". The current LTC is shown. (During playback, you can see LTC running. ) 2. At the desired point, press the [ENTER/YES] key. The currently displayed LTC value is set as the chase offset. H OFFSET M S F SF H OFFSET CHASE M S F SF Flashing Flashing 3. To exit the TC Setup mode, press the [EXIT/NO] key (or the [STOP] key). · Chase mode selection You can select the chase mode to the reference time code from among the following 3 modes. Tips: To make the unit chase to the reference time code, press the [CHASE] key to activate the chase mode. When activating the chase mode, the [CHASE] key flashes, as well as "CHASE" flashes in red on the display. When the unit locks to the reference time code, both the [CHASE] key and "CHASE" on the display are lit steadily. Once In this mode, once the unit locks to the incoming time code after activating the chase mode (by pressing the [CHASE] key), it stops chasing and runs freely, ignoring the incoming time code. The unit does not rechase the time code even if it runs out of sync to the time code. In this mode, once the unit locks to the incoming time code after activating the chase mode (by pressing the [CHASE] key), it stops chasing and runs freely, ignoring the incoming time code. The unit rechases the incoming time code if it runs out of sync to the time code. In this mode, after the unit locks to the incoming time code, it continues to monitor the incoming time code and control the speed to keep locking to the incoming time code by using the small amount of vari speed which is inaudible. The unit rechases the incoming time code if it runs out of sync to the time code. Continue Frame Sync 1. Use the jog dial (or [SKIP/CURSOR] [|<<] / [>>|] keys) to select "Chase MD?". The current chase mode is shown. 2. Press the [ENTER/YES] key. The current chase mode starts flashing. Flashing Flashing 3. Use the jog dial to select a desired chase mode and press the [ENTER/YES] key. The selected chase made is set and the display returns to show "ChaseMD?". 4. To exit the TC Setup mode, press the [EXIT/NO] key (or the [STOP] key). 5-9 · Time code output on/off selection while paused you can select whether to output time code from the [TIME CODE OUTPUT] connector while paused. Use the jog dial (or [SKIP/CURSOR] [|<<] / [>>|] keys) to select "Pause TC?". The current setting is shown (the default is "Off"). 2. Press the [ENTER/YES] key. The currently value flashes and you can now edit it. Flashing Flashing 3. [. . . ] Reference level : -12 dB/-18 dB/-20 dB (default: -18 dB, selectable from the "Reference Level?" menu in the Setup mode) Nominal input level : +4 dBu/-10 dBV (balanced), selectable using the input level select switch on the rear panel ANALOG INPUTs (TR 1 through TR 4) · · · · Connector Input impedance Nominal input level Maximum input level : : : : XLR-3-31 type (balanced, pin 2: hot) 10k or more +4 dBu +24 dBu ANALOG OUTPUTs (TR 1 through TR 4) · · · · Connector Applicable load impedance Nominal output level Maximum output level : : : : XLR-3-32 type (balanced, pin 2: hot) 600 or more +4 dBu +24 dBu Monitor OUTPUTs (TR 1 through TR 4) · · · · Connector Applicable load impedance Nominal output level Maximum output level : : : : 1/4" phone jack (unbalanced) 10k or more -10 dBV +10 dBV PHONES output · · · * Connector Applicable load impedance Maximum output level Monitor track(s) selectable : 1/4" phone jack : 8 or more : 100 mW (into 32 ohms) using the [PHONES] switches on the front panel. DIGITAL INPUTs (TR 1-2, TR 3-4) · Connector · Format : : XLR-3-31 type IEC 60958 (S/PDIF) or IEC 60958 (AES/EBU), automatically detected DIGITAL OUTPUTs (TR 1-2, TR 3-4) XLR-3-32 type IEC 60958 (S/PDIF) or IEC 60958 (AES/EBU), selectable by the "D. OUT?" menu in the Setup mode * When dealing with a digital signal at 176. 4 kHz or 192 kHz sampling rate, channels L and R are assigned to TR 1-2 and TR 3-4 respectively. · Connector · Format : : GPI IN/OUT · Connector : DIN 5-pin * ON or OFF selectable by the "GPI?" setting menu in the Setup mode. GPI IN Pin 1: Pin 2: Pin 3: Pin 4: GND STOP The "low" pulse activates the function equivalent to the [STOP] key. PLAY The "low" pulse activates the function equivalent to the [PLAY] key. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX DV40

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX DV40 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag