User manual FOSTEX X-26

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FOSTEX X-26. We hope that this FOSTEX X-26 user guide will be useful to you.

Lastmanuals help download the user guide FOSTEX X-26.


Mode d'emploi FOSTEX X-26
Download
Manual abstract: user guide FOSTEX X-26

Detailed instructions for use are in the User's Guide.

[. . . ] Heed warnings - All warnings on the appliance and in the operating instructions should be adhered to. Follow instructions - All operating and use instructions should be followed. Water and Moisture - The appliance should not be used near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufacturer. [. . . ] 5) Next, check if the tape speed variable range satisfies the specifications below. Maximum tape speed: +12 % or more (3360 Hz or more) Minimum tape speed: -45 % or less (1650 Hz or less) 3-8. Playback Level Calibration 1) Set the controls as follows. Record track select switch: OFF Dolby B noise reduction on/off switch: OFF 2) Connect an AC volt meter to the TAPE OUT 1 through 4 pin jacks. 10 X-26 3) Playback the TCW-231 test tape and check the output level if it is -10 dBV (0. 3 V) ± 1 dB reading. 4) If the reading is not within the above range, adjust R106 ~ R406 on the R/P AMP PCB assy. 3-9. Playback Frequency Response Calibration 1) Set the controls as follows. Record track select switch: OFF Dolby B noise reduction on/off switch: OFF 2) Connect an AC volt meter to the TAPE OUT 1 through 4 pin jacks respectively. 3) Playback the TCW-284F test tape and adjust R103 ~ R403 so that the output level at 6. 3 kHz is 0. 5 dB lower than the 400 Hz output level. 4) Confirm that the output level at 12. 5 kHz is within ± 1 dB of the 400 Hz output level. 3-10. Erase Current Adjustment At adjusting the erase current, put a blank cassette tape to the transport and the track to be adjusted is put in REC mode. 5) Release the PAUSE button and start recording the signal. 6) After recording a certain length, rewind the tape to the start point of recording section. Then, playback the tape and check the level at TAPE OUT 1 ~ 4. If the AC volt meter reading is not within -10 dBV (0. 3 V) ± 0. 5 dB, adjust the pot R121 ~ 421 (22 k) on the R/P PCB assy. Overall Frequency Response Adjustment 1) Set the controls under the same condition as 3. 12 except the DOLBY switch. (The switch should be turned on. ) 2) Apply a 400 Hz, -35 dBV (18 mV) signal to the INPUT 1 and 2 phone jacks. 3) Record the signal, rewind and playback the recorded section of the tape and memorize the output level at TAPE OUT 1 ~ 4. 4) Next, apply 6 kHz & 12 kHz, -35 dBV (18 mV) signals to the INPUT 1 and 2 phone jacks. 5) Record the signal, rewind and playback the recorded section of the tape. 6) Check if the 6 kHz / 12 kHz output level at TAPE OUT 1 ~ 4 is within ± 2 dB comparing to the 400 Hz output level. If the AC volt meter reading is not within the above specification, adjust the pot R133 ~ 433 (220 k) on the R/P AMP PCB assy so that the recording level at 6 kHz will be within the specification. 3-14. [. . . ] R001~007 8230 1387 51 R010~012 8230 1381 23 R013 8230 1384 73 R103, 203 8230 1381 02 R104, 204 8230 1381 02 R105, 205 8230 1381 04 R106, 206 8230 1381 04 R107, 207 8230 1384 73 Description HT, carbon, 1/4W, 750, 5% HT, carbon, 1/4W, 12k, 5% HT, carbon, 1/4W, 47k, 5% HT, carbon, 1/4W, 1k, 5% HT, carbon, 1/4W, 1k, 5% HT, carbon, 1/4W, 100k, 5% HT, carbon, 1/4W, 100k, 5% HT, carbon, 1/4W, 47k, 5% C001, 002 8232 1424 76 C005, 006 8232 1424 76 C010 C011 C012 C013 8232 8012 21 8232 8012 20 8232 8012 21 8232 8012 20 C014 8232 1431 06 C103, 203 8232 1421 07 C104, 204 8232 1421 07 C105, 205 8232 8011 00 C106, 206 8232 8011 00 19 X-26 Ref. No. Part No. Description VT, ALU, 16V, 10µF, 20%, SME VT, ALU, 16V, 10µF, 20%, SME VT, ALU, 16V, 10µF, 20%, SME Wire, jumper, IPS-1041-2, F5 N/A N/A VT, ALU, 16V, 10µF, 20%, SME VT, ALU, 16V, 10µF, 20%, SME VT, ALU, 16V, 10µF, 20%, SME VT, CER, 50V, 220pF, 5%, SL VT, CER, 50V, 22pF, 5%, SL VT, ALU, 16V, 10µF, 20%, SME VT, CER, 50V, 220pF, 5%, SL VT, CER, 50V, 22pF, 5%, SL VT, ALU, 16V, 10µF, 20%, SME VT, ALU, 10V, 470µF, 20%, SME Ref. No. Part No. Description Resistor, HT, carbon, 1/4W, 12k, 5% N/A N/A Wire, jumper, IPS-1041-2, F5 Wire, jumper, IPS-1041-4, F10 C107, 207 8232 1431 06 C108~408 8232 1431 06 C109~409 8232 1431 06 C110~410 C111~411 C112~412 C113~413 8232 1431 06 C114~414 8232 1431 06 C115~415 8232 1431 06 C150, 250 8232 8012 21 C151, 251 8232 8012 20 C152, 252 8232 1431 06 C153, 253 8232 8012 21 C154, 254 8232 8012 20 C155, 255 8232 1431 06 C156, 256 8232 1424 77 R102, 202 8230 1381 23 C101, 201 C102, 202 E001 E002 J001 J002 J003 J005 J006 J101, 201 J102, 202 W004 Y901 8245 1711 03 8245 1712 03 8245 1713 03 8245 2980 00 8245 2980 00 8245 3390 04 8245 2680 04 8276 9082 20 8207 0122 02 Connector, PI, jack, 8283, 3P, WHT Connector, PI, jack, 8283, 3P, RED Connector, PI, jack, 8283, 3P, BLK Connector, PL, jack, phone, LGR4609-7000 Connector, PL, jack, phone, LGR4609-7000 Connector, PL, jack, phone, YKB21-5074 Connector, PL, jack, XLR31, NC3FAHR10 Cable, flat, 2P, L200 Holder, cable, 2P, 51048 MISCELLANEOUS Ref. Description Wire, jumper, IPS-1041-2, F5 Wire, jumper, IPS-1041-4, F10 Connector, PL, jack, RCA, 2P, BLK Connector, PI, jack, 1P, RT-01T-1. 0B Connector, PL, jack, phone, LGR4609-7000 Switch, PT, tact, SOR-112HS Holder, cable, 9P, 51048 Holder, cable, 13P, 51048 Holder, cable, 8P, 51048 Holder, cable, 6P, 51048 Cable assy, shield 2C, 3P, WHT-9073, L150 Cable assy, shield 2C, 3P, RED-9073, L300 Cable assy, shield 2C, 3P, BLK-9073, L500 Cable, flat, 6P, L250 Cable, flat, 13P, L250 Cable, flat, 8P, L250 Cable, flat, 9P, L250 8245 2120 01 8245 5280 01 8245 2980 00 · R/P PCB Ref. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FOSTEX X-26

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FOSTEX X-26 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag