If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FRIEDLAND REPONSE ALARMS SA3. We hope that this FRIEDLAND REPONSE ALARMS SA3 user guide will be useful to you.

Lastmanuals help download the user guide FRIEDLAND REPONSE ALARMS SA3.


Mode d'emploi FRIEDLAND REPONSE ALARMS SA3
Download
Manual abstract: user guide FRIEDLAND REPONSE ALARMS SA3

Detailed instructions for use are in the User's Guide.

[. . . ] SA3 6 Zone Wirefree Alarm System ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 FIRE TAMPER 1 4 7 2 5 8 0 3 6 9 # ESC ENTER * Installation & Operating Manual FOREWORD All components in this wirefree Alarm System are designed and manufactured to provide a high standard of security protection and long, reliable service. The system is designed for ease of installation using only conventional domestic tools. However, it is essential that the installer reads and fully understands the advice and procedures contained in this manual and plans the system before proceeding with the installation. During installation, it is important that the procedures described in this manual are followed in sequence. [. . . ] Mounting the device on a north facing wall should be avoided as this could mean that during the short dark days of winter months the solar panel may not receive sufficient daylight in order to maintain the battery charge at acceptable levels. NORTH Avoid if possible INSTALLING AND CONFIGURING THE SOLAR SIREN (See diagram overpage). Remove the fixing screw from the bottom edge of the Siren housing and carefully hinge off the front cover. All electronic components are housed within the front cover. Hold the mounting plate in position and mark the positions of the four mounting holes. A spirit level placed on the casing will ensure a perfect level. Drill four 6mm holes and fit the wall plugs 3. Fit the two 30mm fixing screws in the top holes leaving approximately 10mm of the screw protruding. Fit the top keyhole slots of the mounting plate over the screw heads. Remove the mounting plate and adjust the screws until they form a neat fit with the mounting plate with minimal movement. Secure the mounting plate in position using the two 25mm fixing screws in the bottom fixing holes. Ensure that the Solar Siren main configuration switch on the LED indicator board is set to "SIREN" for use with this alarm system. Main Configuration Switch (in SIREN Position) C. U. SIREN WEST EAST SOUTH SA3 15 INSTALLATION Ensure that the position selected for the Siren is within effective range of the Control Panel, (refer to "Testing the Control Panel & Remote Control"). Solar Panel Receiver Aerial Tamper switch Front cover locating tabs DIP switch cover P2 P3 P1 ON 1 2 3 4 5 6 7 8 9 7. 5 Volt DC charging adaptor input Beep Disable Link Siren Disable Link Jamming Detection Link 6 Volt 1. 2Ahr rechargeable battery 9 Volt PP3 initial power up battery Main Configuration Switch (in SIREN Position) C. U. SIREN Printed circuit board enclosure C. U. SIREN House Code DIP switches 1-8 Alarm duration DIP switch 9 LED Indicator PCB Siren INSTALLATION 7. Undo the 3 screws holding the DIP Switch Cover in place and remove the cover. Under the cover you will find a series of 9 DIP switches. Note: When the Solar Siren is viewed as shown above (Solar panel at top) the DIP switches are `upside down'. DIP switches 1-8 are used to set the House Code for the Siren and must be set to the same ON/OFF combination as all other system devices. Alarm Duration DIP switch 9 ON to acknowledge signals from the Remote Control, (provided the beep feature is not disabled). P3 fitted P3 removed Siren enabled Siren disabled 13. To enable the Jamming Detect feature in the Solar Siren fit the jumper link taped to the cover of the Siren control unit across link pins P1 on the circuit board. P1 fitted P1 removed Jamming Detection enabled Jamming Detection disabled 14. Refit the DIP switch cover and replace the three cover fixing screws. [. . . ] Ensure DIP switches 1, 2 and 3 of SW2 are correctly set, (i. e. Ensure that detector is mounted the correct way up, (i. e. Ensure that the detector is mounted at the correct height, (i. e. Allow 2-3 minutes for detector to stabilize and become fully operational. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FRIEDLAND REPONSE ALARMS SA3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FRIEDLAND REPONSE ALARMS SA3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag