User manual FUJITSU MPD3XXXAT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FUJITSU MPD3XXXAT. We hope that this FUJITSU MPD3XXXAT user guide will be useful to you.

Lastmanuals help download the user guide FUJITSU MPD3XXXAT.


Mode d'emploi FUJITSU MPD3XXXAT
Download
Manual abstract: user guide FUJITSU MPD3XXXAT

Detailed instructions for use are in the User's Guide.

[. . . ] MPD3xxxAT DISK DRIVES PRODUCT MANUAL C141-E069-02EN REVISION RECORD Edition 01 02 Date published Dec. , 1998 Apr. , 1999 Model name is changed from MPD3129AT to MPD3130AT. Formatted Capacity is changed from 12. 97 GB to 13. 02 GB according to above change. Revised contents Specification No. : C141-E069-**EN The contents of this manual is subject to change without prior notice. Copyright © 1999 FUJITSU LIMITED C141-E069-02EN i This page is intentionally left blank. PREFACE This manual describes the MPD3xxxAT series, a 3. 5-inch hard disk drive with a BUILT-IN controller that is compatible with the ATA interface. [. . . ] Interrupts are generated when the DRQ bit of the Status register is set at the beginning of each block or partial block. C141-E069-02EN 5 - 23 The contents of the command block registers related to addresses after the transfer of a data block containing an erred sector are undefined. To obtain a valid error information, the host should retry data transfer as an individual requests. At command issuance (I/O registers setting contents) 1F7H(CM) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(FR) 1 × 1 L 0 × 0 DV 0 1 0 1 Start head No. / LBA [LSB] Transfer sector count xx At command completion (I/O registers contents to be read) 1F7H(ST) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(ER) Note: When the command terminates due to error, only the DV bit and the error information field are valid. × L × Status information DV End head No. / LBA [LSB] 00H Error information (7) WRITE DMA (X'CA' or X'CB') This command operates similarly to the WRITE SECTOR(S) command except for following events. · · · The data transfer starts at the timing of DMARQ signal assertion. The device controls the assertion or negation timing of the DMARQ signal. The device posts a status as the result of command execution only once at completion of the data transfer. When an error, such as an unrecoverable medium error, that the command execution cannot be continued is detected, the data transfer is stopped without transferring data of sectors after the erred sector. The device generates an interrupt using the INTRQ signal and posts a status to the host system. The format of the error information is the same as the WRITE SECTOR(S) command. A host system can be select the following transfer mode using the SET FEATURES command. 5 - 24 C141-E069-02EN 1) Multiword DMA transfer mode 2: Sets the FR register = X'03' and SC register = X'22' by the SET FEATURES command 2) Ultra DMA transfer mode 2: Sets the FR register = X'03' and SC register = X'42' by the SET FEATURES command At command issuance (I/O registers setting contents) 1F7H(CM) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(FR) R = 0 or 1 At command completion (I/O registers contents to be read) 1F7H(ST) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(ER) × L × Status information DV End head No. /LBA [MSB] 1 × 1 L 0 × 0 DV 1 0 1 R Start head No. / LBA [LSB] Transfer sector count xx End cylinder No. / LBA [LSB] 00 (*1) Error information *1 If the command is terminated due to an error, the remaining number of sectors of which data was not transferred is set in this register. (8) WRITE VERIFY (X'3C') This command operates similarly to the WRITE SECTOR(S) command except that the device verifies each sector immediately after being written. The verify operation is a read and check for data errors without data transfer. Any error that is detected during the verify operation is posted. At command issuance (I/O registers setting contents) 1F7H(CM) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(FR) 0 × 0 L 1 × 1 DV 1 1 0 0 Start head No. / LBA [LSB] Transfer sector count xx C141-E069-02EN 5 - 25 At command completion (I/O registers contents to be read) 1F7H(ST) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(ER) × L × Status information DV End head No. / LBA [LSB] 00 (*1) Error information *1 If the command is terminated due to an error, the remaining number of sectors of which data was not transferred is set in this register. (9) RECALIBRATE (X'1x', x: X'0' to X'F') This command performs the calibration. Upon receipt of this command, the device sets BSY bit of the Status register and performs a calibration. When the device completes the calibration, the device updates the Status register, clears the BSY bit, and generates an interrupt. This command can be issued in the LBA mode. At command issuance (I/O registers setting contents) 1F7H(CM) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(FR) 0 × 0 × 0 × 1 DV xx xx xx xx xx x x xx x x At command completion (I/O registers contents to be read) 1F7H(ST) 1F6H(DH) 1F5H(CH) 1F4H(CL) 1F3H(SN) 1F2H(SC) 1F1H(ER) × × × Status information DV xx xx xx xx Error information xx 5 - 26 C141-E069-02EN (10) SEEK (X'7x', x : X'0' to X'F') This command performs a seek operation to the track and selects the head specified in the command block registers. [. . . ] However an interrupt of abnormal end is not generated when a write automatic assignment succeeds. However, since the host may issue several write commands before the drive generates an interrupt of abnormal end, the host cannot recognize that the occurred error is for which command generally. Therefore, it is very hard to retry the unrecoverable write error for the host in the write cache operation generally. So, take care to use the write cache function. C141-E069-02EN 6 - 21 Comments concerning this manual can be directed to one of the following addresses: FUJITSU LIMITED Business Planning Solid Square East Tower 580 Horikawa-cho, Saiwai-ku, Kawasaki, 210-0913, Japan TEL: 81-44-540-4056 FAX: 81-44-540-4123 FUJITSU COMPUTER PRODUCTS OF AMERICA, INC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FUJITSU MPD3XXXAT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FUJITSU MPD3XXXAT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag