User manual FURMAN PLPRO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURMAN PLPRO. We hope that this FURMAN PLPRO user guide will be useful to you.

Lastmanuals help download the user guide FURMAN PLPRO.


Mode d'emploi FURMAN PLPRO
Download
Manual abstract: user guide FURMAN PLPRO

Detailed instructions for use are in the User's Guide.

[. . . ] 12 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 1 PL-PRO, PL-PRO-E SPECIFICATIONS Note: Where different, PL-PRO-E specs are in parentheses. Current rating: 20 Amps, 2400 watts at 120 VAC (16 Amps, 3600 watts at 230 VAC) Input Voltage Range: 0 to 280 VAC without damage Meter Accuracy: Voltmeter: ± 2 (±4) VAC; Ammeter: ± 2 amps, calibrated with trimpot adjustments Spike Protection Modes: Line to neutral, neutral to ground, line to ground Clamping Voltage, all modes: TVSS rating 400V peak, L-N, L-G, N-G, tested to UL 1449 (TVSS rating 400V peak, L-N; 680V peak, L-G, N-G) Response time: 1 nanosecond Maximum surge current: 11, 000 amps (8 x 20mS pulse) Maximum spike energy: 550 joules total Noise attenuation: Differential mode: Greater than 40 dB; Common mode: greater than 60 dB; both 1 to 200 MHz Dimensions: 1. 75" (4. 45 cm) H x 19" (48. 25 cm) W x 8" (25 cm) D. Construction: Steel chassis, zinc chromate plating; brushed and black anodized aluminum front panel; glass epoxy printed circuit boards. Power consumption: 32 watts Safety Information: PL-PRO: UL listed. PL-PRO-E: CE Options: "-G" Suffix (PL-PRO only): provides "super spec", isolated ground 120V outlets for special applications. [. . . ] If you find that the heat from the tubes is excessive, try reducing the setting of the dimmer knob. Do not attempt to service the PL-PRO beyond what is described in this manual. All other servicing should be referred to qualified service personnel. Power Status LEDs The PL-PRO's status LEDs inform you of abnormal conditions at a glance: Symptom: Possible Cause: Action Needed: Symptom: Possible Cause: Action Needed: Symptom: Possible Cause: Action Needed: PROTECTION OK Indicator not lit. (If only the LED under the 90V mark is flashing, PL-PRO is receiving 80-90V). Consider installing a Furman voltage regulator. Input voltage is below 80 or above 140 volts, causing power to the PL-PRO's outlets to be shut down. Consider installing a Furman voltage regulator. PROTECTION EXTREME OK VOLTAGE GROUND OK FLASHES WHEN SHUT DOWN Symptom: Possible Cause: Action Needed: Voltmeter Displays The PL-PRO informs you of voltage problems at a glance. The following chart summarizes how the PL-PRO's voltmeter responds to input voltages from extremely low to extremely high. 90 100 110 120 128 AC VOLTS HING DISPLAY INDICATES OUT-OF-RANGE -- PROTECTIVE SHUTDOWN MAY OC Mains Vltg. Voltage Status Below 80V 80-90 90-104 106-108 110-120 122-124 126-128 130-140 Above 140 Extreme (Shutdown) Low Marginal Low Medium Low Normal Medium High High High Marginal Extreme (Shutdown) PL-PRO Voltmeter Reading Meter off--Extreme Voltage LED flashes The LED beneath the 90V mark flashes Meter Reads in Low Red Meter Reads in Low Yellow Meter Reads in Green Meter Reads in High Yellow Meter Reads in High Red All Meter LEDs Flash Meter off--Extreme Voltage LED Flashes Outlets OFF ON ON ON ON ON ON ON OFF 8 PL-PRO POWER CONDITIONER AND LIGHT MODULE PL-PRO POWER CONDITIONER AND LIGHT MODULE 5 NOTE: The Voltmeter and status LEDs stay on even when the power switch is off. This feature allows you to check voltage before powering up your equipment. These LEDs are designed for continuous, ongoing use. What sets the Furman PRO Series apart from other conditioners is the quantity, quality, and configuration of its suppression devices. These include MOV's, gas discharge tubes, fast-blow fuses, and high voltage inductors and capacitors. This unique combination can safely absorb and dissipate large spikes from nearby lightning strikes and other sources (up to 11, 000 amps across any wiring mode -- hot-neutral, hot-ground, or neutral-ground), as well as highly attenuate audible high frequency noise. Precise high-inrush magnetic circuit breakers avoid the false tripping often encountered with large reactive loads like power amps. The PL-PRO front panel provides a three-color, 20-LED line voltage meter, and three status LEDs to indicate abnormal power conditions. Under extreme conditions, the PL-PRO will even keep itself from turning on, or shut down if the voltage is below 80 volts or above 140 volts (below 160 V or above 280 V for the PL-PRO-E). There is a dimmer control for the two front panel light tubes, which also include a feature exclusive to Furman that automatically turns both lights off when either light tube is pushed back in. The front panel also provides an unswitched outlet (clean, filtered power is provided at the unswitched outlet, too) and a 20 amp (16 amp for PL-PRO-E) magnetic circuit breaker rated for use as an ON/OFF switch. The rear has eight switched AC outlets to power up all your equipment. These outlets are spaced widely enough to accommodate up to four plug-mounted power supplies ("wall warts"). [. . . ] Unscrew the cap on the end of each tube to get access to the bulb. (Be careful not to push the tubes in after you have removed the caps. ) To unscrew the bulb, place your index finger across the hole on the underside of the tube and in contact with the bulb. Use the ball of your finger to rotate the bulb out of its socket. Then remove the bulb from the front of the light tube. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURMAN PLPRO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURMAN PLPRO will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag