User manual FURMAN PSPROHT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURMAN PSPROHT. We hope that this FURMAN PSPROHT user guide will be useful to you.

Lastmanuals help download the user guide FURMAN PSPROHT.


Mode d'emploi FURMAN PSPROHT
Download
Manual abstract: user guide FURMAN PSPROHT

Detailed instructions for use are in the User's Guide.

[. . . ] PS-PRO HT - POWER CONDITIONER/SEQUENCER MODEL: PS-PRO HT Owner's Manual Featuring 3-Channel Sequencing, 20 Amp Capacity, Over Voltage Shutdown, and Programmable Home Theater Pro Level AC Power Conditioner/Sequencer PS-PRO HT - POWER CONDITIONER/SEQUENCER F E AT U R E S 20 amp (2400 watt) rating handles even the largest power amplifiers. Multiple levels of protection components can safely absorb large voltage spikes and provide highly effective RFI / EMI filtering. Extreme Voltage Shutdown guards against catastrophically high voltages. Power Status LED's indicate which outlet groups have power. [. . . ] (Continued on page 7) (Continued from page 4) Disconnecting initiates an ON sequence. If the cable run is long, it is recommended that the REM wire be tied to the PS-PRO HT's GND terminal during ON operation rather than leaving it floating. This will require the use of a third conductor and a double-throw switch. REM to +12V = ON (jumper plug installed on JMP3, MAINT OFF) Defaut Setting The connection of the REM terminal to the +12V terminal initiates an ON sequence. Disconnecting initiates an OFF sequence. If the cable run is long, it is recommended that the REM wire be tied to the PS-PRO HT's GND terminal during OFF operation rather than leaving it floating. REM to GND = ON (jumper plugs installed on JMP1 and JMP4) 4 PS-PRO HT - POWER CONDITIONER/SEQUENCER FRONT PANEL START ON/OFF SEQUENCE: This pushbutton switch is used only when the key lock switch is in REM position and the PS-PRO HT is in Momentary Mode. It then acts the same as any other remote momentary switch that may be connected to the rear panel terminal strip. If the switched outlets are on, pushing it begins an OFF sequence. If they are off, pushing it begins an ON sequence. Do not use this switch when in Maintained Mode. PROTECTION OK: This LED is normally on when the power to the PS-PRO HT's outlets is switched on. It monitors the integrity of the protection devices and reports if the protection is compromised. If an extremely large spike is encountered that exceeds the PS-PRO HT's capacity, the main group of input protectors will blow an internal fuse, causing the indicator to go out. POWER STATUS (DELAY) LEDs: One green LED is provided for each of the three delay stages. Each LED lights when power is applied to its corresponding duplex outlet on the rear panel. All three LEDs then remain steadily lit until power is removed. During the power-down delay cycle, each LED goes off as power to its corresponding outlet is removed. In addition, the Delay 1 LED flashes if a remote switch (or the stored state) is OFF. UNSWITCHED OUTLET: This convenient outlet provides power at all times when the PS-PRO HT is plugged in and operating under normal power conditions. ON/REM/OFF SWITCH: When turned to the ON position, this key lock switch initiates an ON sequence, applying power to the PS-PRO HT's switched outlets. When turned to the OFF position, it begins an PS-PRO HT - POWER CONDITIONER/SEQUENCER OFF sequence. [. . . ] If the LED does not light when the switch is in the ON position check the polarity and reverse the LED leads if needed. Effects of Lightning 8 PS-PRO HT - POWER CONDITIONER/SEQUENCER Three Year Limited Warranty The Furman PS-PRO HT is protected by a limited three year warranty, covering defects in materials and workmanship, provided that the registration card is filled out and returned by the customer. Products must have a proof of purchase from a Furman authorized dealer. During this period, Furman will make any necessary repairs without charge for parts or labor. Shipping charges to the factory or repair station must be prepaid by the owner; return shipping charges (via UPS Ground) will be paid by Furman. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURMAN PSPROHT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURMAN PSPROHT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag