User manual FURUNO DS-80 OPERATORS MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO DS-80. We hope that this FURUNO DS-80 user guide will be useful to you.

Lastmanuals help download the user guide FURUNO DS-80.


Mode d'emploi FURUNO DS-80
Download
Manual abstract: user guide FURUNO DS-80OPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] DOPPLER SPEED LOG Marine Speed and Distance Measuring Equipment (SDME) DS-80 Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : FEB. OME-72470 ( DAMI ) DS-80 *00080889601* *00080889601* *00080889601* *OME72470M10* *OME72470M10* *OME72470M1* SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Immediately turn off the power at the switchboard if water leaks into the equipment or an object is dropped into the equipment. [. . . ] Press the Omnipad at to select DISTANCE RUN DISPLAY and press the [ENT] key. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET OFF SET 0. 00nm ENT SET Cursor 4. Press the Omnipad at the digit to change. or to select 5. Press the Omnipad at or to change value. The setting range is 0. 00 nm to 999999. 99 nm. Press the [ENT] key followed by pressing the [MENU] key twice to conclude your selection and close the menu. 3. Select DATA DISPLAY and press the [ENT] key. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET IEC61162(VLW) OFF SET CONTACT CLOSURE 0 . 0 0 nm ENT SET 1. 6. 3 Resetting distance run to zero Distance run can be reset to zero when the menu item DATA DISPLAY is selected to CONTACT CLOSURE. It may also be reset to zero only at the display unit when IEC 61162(VLW) is selected. Press the Omnipad at DISTANCE RUN DISPLAY and press the [ENT] key. Select RESET and press the [ENT] key. DISTANCE RUN DISPLAY DATA DISPLAY CONTACT CLOSURE RESET OFF SET OFF ON 4. Press to select IEC 61162(VLW) and press the [ENT] key. Press the [MENU] key twice to close the menu. 1. 6. 2 Adjusting distance run Distance run can be changed when the menu item DATA DISPLAY is selected to CONTACT CLOSURE. It may also be changed only at the display unit when IEC 61162(VLW) is selected. Use to select DISTANCE RUN DISPLAY and press the [ENT] key. Select SET and press the [ENT] key. 4. Press the Omnipad at to select ON. 8 5. Press the [ENT] key to finish and press the [MENU] key twice to close the menu. The distance run indication reads 0. 00. 3. Select averaging time period desired among 15, 30, 45 and 60 seconds. Press the [MENU] key twice to close the menu. 1. 7 System Setting 1. 7. 3 Speed offset (calibration) Calibration of any speed log is necessary through the sea trials during the commissioning tests. Fill in the calibration sheet which is on page 25 of this manual. Us the resultant data to calculate speed offset and enter it as below. [. . . ] C7247-K02-A 2000-01 Block. No. SYMBOL TYPE CODE No. REMARKS SHIPPABLE ASSEMBLY PRINTED CIRCUIT BOARD 65P6020, KCP POWER SUPPLY ASSEMBLY DS-810 SWITCH S-331 VARISTOR ERZV-20D471 TRANSFORMER 65S1218 TERMINAL BOARD F1003-20A-5725-6P NOISE FILTER ZGB2202-01U CABLE w/CONNECTOR 66-045(2P) 65-046(6P) 002-889-570 X 002-889-530 X S1 000-474-214 CR1 000-136-287 T1 000-142-647 TB101 000-137-321 XF1 000-132-968 002-889-550 002-889-560 VH CONNECTOR VH CONNECTOR 27 Model Unit DS-80 DISTRIBUTOR DS-801 ELECTRICAL PARTS LIST Ref. Dwg. C7247-K03-A 2000-01 Block No. SYMBOL TYPE CODE No. REMARKS SHIPPABLE ASSEMBLY PRINTED CIRCUIT BOARD 65P6010, JPW ASSEMBLY DS-801 POWER SUPPLY ASSEMBLY DS-801-100 DS-801-110 DS-801-115 DS-801-200 DS-801-220 DS-801-230 SWITCH S-331 VARISTOR ERZV-20D471 TERMINAL BOARD F1003-20A-2P FUSE HOLDER FH-001AF POWER SUPPLY FAW-24-2R1 NOISE FILTER ZAC2210-11 002-889-490 X POWER SUPPLY 002-889-470 X X X X X X X 002-889-410 002-889-420 002-889-430 002-889-440 002-889-450 002-889-460 S1 000-474-214 CR1 000-136-287 TB101 000-142-631 F1 000-138-909 PD1 000-142-633 XF1 000-120-155 28 CALIBRATION SHEET FOR DS-80 DOPPLER SPEED LOG TEST SITE Ser. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO DS-80

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO DS-80 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag