User manual FURUNO DSC-5R OPERATORS MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO DSC-5R. We hope that this FURUNO DSC-5R user guide will be useful to you.

Lastmanuals help download the user guide FURUNO DSC-5R.


Mode d'emploi FURUNO DSC-5R
Download
Manual abstract: user guide FURUNO DSC-5ROPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Note: If the antenna unit is installed at a close distance in front of the wheel house, your administration may require halt of transmission within a certain sector of antenna revolution. Ask your FURUNO representative or dealer to provide this feature. Distance to Distance to 100 W/m2 10 W/m2 point point 0. 80 m 0. 40 m 0. 20 m 0. 30 m 0. 10 m -11. 20 m 8. 60 m 5. 80 m 4. 20 m 3. 00 m 2. 40 m Model3 FAR-2827/2127 FAR-2827/2127 FAR-2827/2127 FAR-2817/2117 FAR-2817/2117 FAR-2817/2117 FAR-2137S FAR-2137S FAR-2827W FAR-2827W FAR-2837S FAR-2837S FAR-2837SW FAR-2837SW 1 XN12AF: 4 ft TR unit RTR-079 RTR-079 RTR-079 RTR-078 RTR-078 RTR-078 RTR-080 RTR-080 RTR-081 RTR-081 RTR-080 RTR-080 RTR-082 RTR-082 Magnetron MG5436 MG5436 MG5436 MG40102 MG40102 MG40102 MG5223F MG5223F MG5436 MG5436 MG5223F MG5223F MG5223F MG5223F Antenna1 XN12AF XN20AF XN24AF XN12AF XN20AF XN24AF SN30AF SN36AF XN20AF XN24AF SN30AF SN36AF SN30AF SN36AF SN30AF: 10 ft 2 Or MAF1425B XN20AF: 6. 5 ft SN36AF: 12 ft XN24AF: 8 ft 3 FAR-2117/2127/2137S available in blackbox configuration. i SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Turn off the radar power switch before servicing the antenna unit. [. . . ] ARP OPERATION 3. 3 Activating, Deactivating ARP To activate or deactivate the ARP: 1. Roll the trackball to place the arrow in the ARP ACQ MODE box at the right side of the display. (Note that "ATA" replaces "ARPA" when the ATA feature is used. ) ARPA AUTO " ON ARPA ACQ MODE box 2. Push the left button to show OFF, MAN or AUTO MAN as appropriate. 3. 4 Entering Own Ship's Speed The ARP requires own ship's speed and heading data. The speed can be STW, BT, SOG or echo-referenced speed (based on 3 max. For automatic or manual input, see paragraph 1. 13. For echo-referenced speed input follow the procedure below. 3. 4. 1 Echo-referenced speed input The use of echo-referenced speed is recommended when: · The speed log is not operating properly or not connected to the radar. · The vessel has no device which can measure ship's leeward movement (Doppler sonar, speed log, etc. ) when leeward movement can not be disregarded. If you select echo-referenced speed, the ARP calculates own ship's speed relative to a fixed reference target. They appear as tracked targets, each shown in a small circle. When a plural of objects are selected, the mean value is used for stabilization and speed. Note that this feature is not available when the AIS is active. Note 1: The ARP ACQ MODE box shows AUTO or AUTO MAN depending on the automatic acquisition condition selected. Note 2: When the menu-set number of automatically acquired targets is reached, the message "TARGET-FULL(AUTO)" is displayed at the right-hand side of screen. 3-5 3. ARP OPERATION 3. 5. 2 Terminating tracking of targets (including reference targets) When the ARP has acquired the menu-set number of targets automatically, the message "TARGET-FULL(AUTO)" appears at the right side of the screen and no more auto acquisition occurs unless targets are lost. Should this happen, cancel tracking of less important targets or perform manual acquisition. Canceling individual targets By keyboard: 1. Roll the trackball to place the cursor (+) on the ARP or reference target to cancel tracking. With the cursor inside the effective display area, roll the wheel to show TARGET CANCEL / EXIT in the guidance box. Roll the trackball to place the cursor on the ARP target or reference target to cancel tracking. Push the left button or the wheel to cancel tracking on the target selected. Roll the trackball to choose the ARP ACQ MODE box at the right side of the screen and then push the right button. [ARP TARGET MENU] 1 ARP SELECT MANUAL100/ AUTO 25/ AUTO 50/ AUTO 75/ AUTO 100 2 ALL CANCEL 3 REF TARGET VECTOR OFF/ON ARP TARGET menu 2. Push the wheel or the left button to cancel tracking on all ARP targets. 3-6 3. [. . . ] 1-16 initializing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15 TX STBY box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 P PAST POSN box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18, 4-12 PICTURE box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 Picture setup choosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 restoring default. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64 user programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-65 Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-71 POWER switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Presentation mode choosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-18 description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19 PRESENTATION MODE box . . . . . . . . . . . . . . . . . . . . 1-18 Pulselength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-25 PULSELENGTH box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-26 Q Quick start. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 R RACON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 Range choosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 RANGE box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 RANGE key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-24 Range ring on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-34 Reference marks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 V Video plotter chart display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO DSC-5R

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO DSC-5R will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag