User manual FURUNO ETR-30N OPERATORS MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO ETR-30N. We hope that this FURUNO ETR-30N user guide will be useful to you.

Lastmanuals help download the user guide FURUNO ETR-30N.


Mode d'emploi FURUNO ETR-30N
Download
Manual abstract: user guide FURUNO ETR-30NOPERATORS MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Back NETWORK SOUNDER ETR-30N SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. WARNING Install the transducer tank according to the installation instructions. Failure to install the tank correctly may result in water leakage and damage to the ship's hull. Turn off the power at the switchboard before beginning the installation. Fire or electrical shock can result if the power is left on. [. . . ] Using a pincers, set jumper block of TAP H (High) referring to the transducer label on the cover. When the NavNet display unit is powered you can confirm setting (see page 10). Note 1: The transducer model recorded on the label is in the unit's memory. Therefore, you can set transducer type following "Transducer connected to the ETR-30N is programmed in the ETR-30N" (page 9. ) Note 2: To connect other make of transducer contact your FURUNO dealer for details. If a low frequency transducer is installed, set TAP L. Close the cover and connect the power cable to the network sounder. Confirm that the HOST NAME control is in the "0" position. J9 . . . . . . . . . . J2 6 HOST NAME Control Sets host name. FURUNO NETWORK SOUNDER ETR-30N HOST NAME 45 6 3 7 2 8 1 09 DEFAULT TX/STBY POWER I ON O OFF POWER switch Turns power On and off. LED lamp The lamp flashes when the NavNet display unit is powered and communicating with the network sounder. ETR-30N 7. Turn on the ETR-30N and the NavNet display unit. Confirm that the LED lamp flashes. 2. 2. 2 Sounder source setting 1. Press the [POWER/BRILL] key on the NavNet series unit while pressing and holding down the [MENU] key. Release the [POWER/BRILL] key when you hear a beep. Release the [MENU] key when the message "STARTING INSTALLATION MODE" appears. After the radar screen appears, press the [MENU] key. Press the SYSTEM CONFIGURATION soft key. Press the INSTALLATION SETUP soft key. RADAR MENU SYSTEM CONFIG INSTALL SETUP RADAR DISPLAY SETUP RADAR RANGE SETUP ARP SETUP FUNCTION KEY SETUP SYSTEM CONFIGURATION GENERAL SETUP NAV OPTION SYSTEM SETUP INSTALLATION SETUP RETURN NETWORK SETUP RADAR SETUP NETWORK SOUNDER SETUP NETWORK SETUP FOR AUX# RETURN Radar menu System configuration menu Install setup menu # =Shown on Model 1833C only How to access the installation setup menu (example: radar NavNet unit) 7 Note: The very first time the system is powered you are asked if you want to start the simulation mode, which provides simulated operation of the equipment. Press the [CLEAR] key to start normal operation to set up the transducer. For further details about the simulation mode, see your NavNet series operator's manual. START SIMULATION MODE?PUSH CLEAR KEY TO SKIP. Simulation mode window 6. Press the NETWORK SETUP soft key. 172. 031. 092. 001 RADAR________ RADAR________ ______________ ______________ ______________ SOUNDER SOURCE SOUNDER AUX* WFAX SUBNET MASK 255. 255. 000. 000 GATEWAY ADDRESS 000. 000. 000. 000 OFFSET PORT NUMBER 10000 IP ADDRESS HOST NAME RADAR SOURCE CHART SOURCE NETWORK SETUP EDIT RETURN * = Model 1833C only. Network setup menu 7. Confirm that the "SOUNDER SOURCE" is SOUNDER. 8 2. 2. 3 Transducer setup CAUTION Enter transducer setting correctly. A wrong transducer setting can damage the transducer. Transducer connected to the ETR-30N is programmed in the ETR-30N 1. [. . . ] Press the [MENU] key, choose SOUNDER SYSTEM SETUP menu and then press the NEXT PAGE soft key. STC - HF STC - LF FREQ. - LF TARGET ECHO 00 00 +00. 0 +00. 0 NORMAL SYSTEM SETUP 2 EDIT PREV PAGE Page 2 of sounder system setup menu STC-HF, LF Adjusts STC level for the high and low frequencies, and is useful for suppressing surface noise. The setting range is 0-10; the higher the setting the greater the degree of suppression. Setting 10 suppresses noise up to about several meters from own ship. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO ETR-30N

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO ETR-30N will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag