User manual FURUNO FCV-1200L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO FCV-1200L. We hope that this FURUNO FCV-1200L user guide will be useful to you.

Lastmanuals help download the user guide FURUNO FCV-1200L.


Mode d'emploi FURUNO FCV-1200L
Download

You may also download the following manuals related to this product:

   FURUNO FCV-1200L OPERATORS MANUAL (1587 ko)

Manual abstract: user guide FURUNO FCV-1200L

Detailed instructions for use are in the User's Guide.

[. . . ] Back COLOR LCD SOUNDER FCV-1200L/1200LM Your Local Agent/Dealer 9-52 Ashihara-cho, Nishinomiya, Japan Telephone : Telefax : 0798-65-2111 0798-65-4200 All rights reserved. Printed in Japan FIRST EDITION : APR. OME-23650 ( DAMI ) FCV-1200L/LM *00080900501* *00080900501* *00080900501* *OME23650N00* *OME23650N00* *OME23650N00* SAFETY INSTRUCTIONS WARNING ELECTRICAL SHOCK HAZARD Do not open the equipment. Only qualified personnel should work inside the equipment. Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped in the equipment. [. . . ] Press the [-] or [+] key to show the alarm setting window. 0 ft Starting depth setting window (ex. For BOTTOM ALARM and FISH ALARM, press the [-] or [+] key to set the starting point of alarm zone. Alarm marker appears (Depth alarm: green, Fish alarm: white). 2-8 Selected alarm (flashing) BTM Start line Alarm area Alarm marker Bottom alarm (green): right side 12. 5ft Fish alarm (white): right side Bottom-fish alarm (white): left side (vertical screen division) right side (horizontal screen division) Setting of alarm zone (ex. Press the [-] or [+] key to show the alarm zone setting window. 10 ft Alarm zone setting window (ex. Press the [-] or [+] key to set the alarm zone. For depth alarm and temp alarm, go to step 16. To set the fish alarm, go to step 13. 13. Press the [ ] key to select ALARM LEVEL. Press the [-] or [+] key to show the level setting window. MIN MID MAX Level setting window 15. Press the [-] or [+] key to set the alarm level. MIN: Alarm triggered against light-blue or stronger fish echoes. MID: Alarm triggered against yellow or stronger fish echoes. MAX: Alarm triggered against red or stronger fish echoes. 16. Rotate the [FUNCTION] switch fully counterclockwise to select EXIT. To cancel an alarm, select OFF at step 6. 2-9 2. 4 TX/RX Menu DISP ALM TX/RX USER-1/2 SYSTEM PRR LEVEL : <High Frequency> STC : GAIN ADJ : RX BAND : TX PULSE : PULSE LENGTH : <Low Frequency> STC : GAIN ADJ : RX BAND : TX PULSE : PULSE LENGTH : (0~20, S) (0~10) + STD STD 0. 2msec (0. 2~5. 0)*2 (0~10) + STD STD 0. 2msec (0. 2~5. 0)*2 *1 *1 Menu for TX/RX setting. [-/+]: Change set, [EXIT (knob)]: Exit *1: FCV-1200L only *2: The setting becomes available when MANUAL is selected at TX PULSE. TX/RX menu PRR LEVEL Changes pulse repetition rate. Normally, the highest rate (20) is used. When in shallow waters second reflection echoes may appear between surface and actual bottom echo. The choice "S" means the ship's speed dependent mode, where the PRR changes automatically with ship's speed. (Requires ship's speed input. ) For further information about the ship's speed dependent mode, see page 1-20. STC (High and Low Frequencies) Adjusts STC level for the high and low frequencies, and is useful for suppressing surface noise. The setting range is 0-10; the higher the setting the greater the extent of suppression. Setting 10 suppresses noise up to about 5 m. Turn off the STC when there is no noise on the screen, otherwise weak echoes may be missed. GAIN ADJ (High and Low Frequencies) Adjusts gain (range: -50 to +50) of transceiver unit selected. Adjust the setting when the GAIN control cannot effectively adjust the gain. 2-10 RX BAND (High and Low Frequencies) Sets amplifier bandwidth of high and low frequency Rx amplifier. When NARROW is selected, the noise suppression is greater however resolution is lower in shallow water. For more effective resolution, select WIDE. TX PULSE (High and Low Frequencies) Sets TX pulselength for high and low frequencies. [. . . ] 3-5 dual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 screen division. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 shift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12 signal level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FCV-1200L

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FCV-1200L will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag