User manual FURUNO FS-1501

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual FURUNO FS-1501. We hope that this FURUNO FS-1501 user guide will be useful to you.

Lastmanuals help download the user guide FURUNO FS-1501.


Mode d'emploi FURUNO FS-1501
Download
Manual abstract: user guide FURUNO FS-1501

Detailed instructions for use are in the User's Guide.

[. . . ] Continued use of the equipment can cause fire or electrical shock. Make sure no rain or water splash leaks into the equipment. Fire or electrical shock can result if water leaks in the equipment. Lead-in Insulator (High Voltage) WARNING Do not open the equipment. Hazardous voltage which can cause electrical shock exists inside the equipment. [. . . ] FS-1501's 2182 kHz setting has priority. x=Single digit denoting class of emission (0: LSB, 1: J3E, 2: H3E, 5: TLX, 6: FAX). x=7-digit frequency from 10 MHz to 10 Hz. x=7-digit frequency from 10 MHz to 10 Hz. Registers set class of emission and Rx/Tx frequency as user channel. Sets ITU channel x=5-digit band and channel number composed of 2-digit band and 3-digit channel. x=0, 1, 2: LOW, 3: HIGH Tunes antenna coupler. #AGS: ON, #AGR: OFF Confirms RF GAIN state. #SQS: ON, #SQR: OFF Confirms Tx output power. OPERATION OF OPTIONAL EQUIPMENT 2. 1 Telex Communication Telex communication is performed with a Narrow-band direct-printing (NBDP) Terminal connected with an SSB transceiver. The recommended terminal for the FS-1501 is the FURUNO DP-5/DP-6. To change setting for another code, repeat steps 2 and 3. Reset the power. 3. 2 Customizing by User The operator can customize several system settings. The table below shows the system codes and their function, setting range and factory setting. Note: FURUNO Electric Company will assume no responsibility for the inconvenience or disturbance to communications due to inadequate or unlawful presetting of this equipment. Code 9942 Function, Setting Key beep ON/OFF A beep sounds when a keying sequence is correctly executed. Factory setting: ON Noise blanker ON/OFF The noise blanker cancels unwanted noise. Factory setting: ON 9943 3-1 9951 Scan/sweep-stop signal level When the receiver detects a signal whose level is stronger than the preset level it stops scanning and receives the signal. The setting on system code 9955 is available only when "0" (SQ working condition) is selected here. Setting range: 0 (Squelch working condition is effective as set on code 9955), 1-10 (S-meter level); Factory setting: 3 9952 Scan/sweep-stop time When a signal is detected, the receiver stops scanning/sweeping and dwells on this channel frequency. When "0" (RX) is selected, the receiver keeps receiving until the traffic goes out of this channel frequency. Define the dwell time between 1 and 99 sec. [. . . ] A channel can be recalled by hitting the keys [CH], [2], [0], [1], [ENT] for channel 201 as an example. CH NO and Rx frequency appear on the display. The channel number is displayed in 4 digits, such as 2001. (Additional zero is inserted automatically. ) The Rx and Tx frequencies are checked by pressing the [ENT] key. A-8 4/6 MHz BAND ITU NBDP (Telex) FREQUENCY TABLE (ITU RR APPENDIX 32) 4 MHz TELEX SHIP RX SHIP TX 4210. 5 4211. 0 4211. 5 4212. 0 4212. 5 4213. 0 4213. 5 4214. 0 4214. 5 4215. 0 4177. 5 4215. 5 4216. 0 4216. 5 4217. 0 4217. 5 4218. 0 4218. 5 4219. 0 4202. 5 4203. 0 4203. 5 4204. 0 4204. 5 4205. 0 4205. 5 4206. 0 4206. 5 4207. 0 4207. 5 4219. 5 4220. 0 4220. 5 4172. 5 4173. 0 4173. 5 4174. 0 4174. 5 4175. 0 4175. 5 4176. 0 4176. 5 4177. 0 4177. 5 4178. 0 4178. 5 4179. 0 4179. 5 4180. 0 4180. 5 4181. 0 4181. 5 4202. 5 4203. 0 4203. 5 4204. 0 4204. 5 4205. 0 4205. 5 4206. 0 4206. 5 4207. 0 4207. 5 4208. 0 4208. 5 4209. 0 6 MHz TELEX SHIP RX SHIP TX 6314. 5 6315. 0 6315. 5 6316. 0 6316. 5 6317. 0 6317. 5 6318. 0 6318. 5 6319. 0 6268. 0 6319. 5 6320. 0 6320. 5 6321. 0 6321. 5 6322. 0 6322. 5 6323. 0 6323. 5 6324. 0 6324. 5 6325. 0 6325. 5 6326. 0 6326. 5 6327. 0 6327. 5 6328. 0 6328. 5 6329. 0 6329. 5 6330. 0 6330. 5 6300. 5 6301. 0 6301. 5 6302. 0 6302. 5 6303. 0 6263. 0 6263. 5 6264. 0 6264. 5 6265. 0 6265. 5 6266. 0 6266. 5 6267. 0 6267. 5 6268. 0 6268. 5 6269. 0 6269. 5 6270. 0 6270. 5 6271. 0 6271. 5 6272. 0 6272. 5 6273. 0 6273. 5 6274. 0 6274. 5 6275. 0 6275. 5 6281. 0 6281. 5 6282. 0 6282. 5 6283. 0 6283. 5 6284. 0 6284. 5 6300. 5 6301. 0 6301. 5 6302. 0 6302. 5 6303. 0 6 MHz TELEX SHIP RX SHIP TX 6303. 5 6304. 0 6304. 5 6305. 0 6305. 5 6306. 0 6306. 5 6307. 0 6307. 5 6308. 0 6308. 5 6309. 0 6309. 5 6310. 0 6310. 5 6311. 0 6311. 5 6312. 0 6331. 0 6331. 5 6332. 0 6303. 5 6304. 0 6304. 5 6305. 0 6305. 5 6306. 0 6306. 5 6307. 0 6307. 5 6308. 0 6308. 5 6309. 0 6309. 5 6310. 0 6310. 5 6311. 0 6311. 5 6312. 0 6312. 5 6313. 0 6313. 5 CH NO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FURUNO FS-1501

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual FURUNO FS-1501 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag